10kV Grade Three-phase Dry-type Grounding Transformer

  • 10kV Grade Three-phase Dry-type Grounding Transformer

Key attributes

Brand ROCKWILL
Model NO. 10kV Grade Three-phase Dry-type Grounding Transformer
Rated voltage 10kV
Rated frequency 50/60Hz
Rated capacity 1000kVA
Series DKSC

Product descriptions from the supplier

Description

Product Description

The 10kV Grade Three-phase Dry-type Grounding Transformer is a specialized electrical device designed to create an artificial neutral point in three-phase power systems that are otherwise ungrounded or impedance-grounded. Utilizing a robust resin-cast insulation system, it provides a safe, reliable, and maintenance-free solution for system grounding. Its primary function is to control transient overvoltages and provide a path for ground fault current, thereby enhancing the safety and stability of the entire 10kV distribution network.

Product model

  • DK: Grounding Transformer

  • S: Three-phase

  • C: Molded Solid

  • First □: Total Capacity (kVA)

  • Second □: Primary Voltage (kV)

  • Third □: Secondary Capacity (kVA)

  • Fourth □: Secondary Voltage (kV)

Product features

Grounding transformer neutral point and line connection, and for exactly neutral electrical grounding system of cattle light produced when the guest of the current can be reduced, the East set point, was sentenced to death for the export, improve the operation of the power system can be, the product conforms to the GB1094.6 "IEC60076-6", the standard for reactance

The product object, a small, high degree of organization. Day think, small volume, decent, calendar, and there can be 8 advantages, can be widely used in power transmission system, electric railway, metallurgy and other cities

Conditions of use

  • Ambient temperature is not higher than 40°C, and altitude does not exceed 1000m.

  • Protection levels are in forms such as IP00, IP20, and IP23.

  • Cooling methods include air natural cooling (AN) and forced air cooling (AF).

Technical Parameters of DKSC Grounding Transformer

Model Specification

Outline Dimensions (Length * Width * Height mm)

Foot Mounting Dimensions (mm)

Total Weight (Kg)

DKSC-250/10.5

1300 * 800 * 1300

660 * 700

900

DKSC-250/10.5

1300 * 800 * 1300

660 * 700

940

DKSC-400/10.5

1350 * 800 * 1300

660 * 700

1000

DKSC-400/10.5-100/0.4

1350 * 800 * 1300

660 * 700

1080

DKSC-630/10.5

1450 * 850 * 1500

660 * 800

1540

DKSC-630/10.5-100/0.4

1450 * 850 * 1500

660 * 800

1600

DKSC-700/10.5-100/0.4

1570 * 850 * 1500

660 * 800

1890

DKSC-800/10.5-200/0.4

1570 * 850 * 1600

660 * 800

1950

DKSC-1000/10.5

1500 * 1070 * 1600

820 * 1020

2000

DKSC-1000/10.5-315/0.4

1550 * 1070 * 1600

820 * 1020

2080

DKSC-1100/10.5-400/0.4

1550 * 1070 * 1600

820 * 1020

2150

DKSC-1200/10.5-200/0.4

1650 * 1070 * 1650

820 * 1020

2370

Note: the above parameters are for reference only and can be customized according to customer requirements.

 

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Southeast Asia Power Solutions: Zig-Zag Grounding Transformer for Cost-Effective & Reliable Grid Stability
    Southeast Asia Power Solutions: Zig-Zag Grounding Transformer for Cost-Effective & Reliable Grid StabilityZig-Zag transformers (also known as Z-connected grounding transformers) offer significant advantages in Southeast Asian power systems due to their unique design, which addresses tropical climates, grid structures, and development needs. Below is an analysis of their core benefits and application scenarios:I. Cost Efficiency & Space Optimization Low-Cost SolutionSimplified constructio
    06/13/2025
  • Intelligent Maintenance Services and Sustainable Solutions for Z-Type Grounding Transformers
    Intelligent Maintenance Services and Sustainable Solutions for Z-Type Grounding TransformersZ-type grounding transformers are critical for stabilizing ungrounded or delta-connected power systems by providing a low-impedance path for zero-sequence currents during faults. Integrating intelligent maintenance and sustainability practices enhances their reliability while minimizing environmental impact. Below is a structured analysis of advanced solutions:I. Intelligent Maintenance Services Real-Time
    06/13/2025
  • ROCKWILL H59 Grounding Transformer Solution: Zig-Zag Winding & Smart Monitoring for Neutral Grounding Systems
    ROCKWILL H59 Grounding Transformer Solution: Zig-Zag Winding & Smart Monitoring for Neutral Grounding SystemsApplication Scenarios:Neutral point grounding in ungrounded or resonant grounded systems, limiting single-phase ground fault current, suppressing system overvoltage.I. Core Design Solutions Customized Grounding Transformer Built on the H59 oil-immersed transformer platform, with high-voltage side using Zig-Zag windings or Yn-d connection to provide stable neutral grounding impedance
    06/13/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.