126kV-550kV PTFE nozzle

  • 126kV-550kV PTFE nozzle

Key attributes

Brand Switchgear parts
Model NO. 126kV-550kV PTFE nozzle
Rated voltage 126-550kV
Series RN

Product descriptions from the supplier

Description

The 126kV-550kV polytetrafluoroethylene (PTFE) nozzle is a key component of the arc extinguishing chamber of high-voltage circuit breakers (such as LW30-126, LW36-126, etc.), and its performance directly affects the breaking capacity and service life of the circuit breaker. The following is a comprehensive technical analysis:
1、 Core performance requirements
Electrical and Thermal Stability
126kV nozzle needs to withstand 550kV lightning impulse voltage, 252kV nozzle needs to meet 950kV impulse voltage, and surface electric field strength ≤ 15kV/mm
Long term working temperature needs to adapt to -200 ℃~260 ℃, and short-term high temperature resistance up to 300 ℃ (such as LW36-126 circuit breaker nozzle)
Mechanical and erosion resistance
It needs to withstand a 50kA short-circuit current impact, with a nozzle inner wall ablation depth of ≤ 0.1mm/time
By using imported PTFE with trace components such as graphite and carbon fiber, the erosion resistance is improved by more than 30%
2、 Materials and processes
Forming process
Adopting the molding sintering process, the sintering temperature is 360 ℃~380 ℃, the pressure is ≥ 10MPa, and the density is ensured to be ≥ 2.15g/cm ³
Surface enhanced bonding strength with metal flanges through plasma treatment or chemical etching
3、 Typical Applications and Standards
Application scenarios
126kV nozzle is used for urban substation circuit breakers (such as LW30-126/3150-40 models)
Industry standards
Must comply with GB/T 11022-2020 "Common Technical Requirements for High Voltage Switchgear and Control Equipment Standards"
The breaking performance test requires passing 100 full capacity short-circuit current tests (such as 40kA/3s)
4、 Technological Challenges and Development
Anti erosion optimization
Reduce arc erosion rate through gradient material design (such as PTFE outer layer+silicon carbide inner layer)

Note: Customization with drawings is available

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.