126kV/800kV drum platform components

  • 126kV/800kV drum platform components
  • 126kV/800kV drum platform components

Key attributes

Brand Switchgear parts
Model NO. 126kV/800kV drum platform components
Rated voltage 126/800kV
Series RN

Product descriptions from the supplier

Description

126kV/800kV cylindrical platform components are key structural parts in high-voltage power equipment, and their design needs to meet insulation, mechanical, and environmental adaptability requirements under high voltage levels. The following is a comprehensive technical analysis:
1、 Design Features and Material Selection
Voltage level difference
126kV cylinder platform components are usually made of epoxy resin composite materials, with a dielectric strength of ≥ 30kV/mm and a local discharge capacity of ≤ 5pC
800kV cylinder platform components require the use of high dielectric constant materials (such as alumina filled epoxy resin) with a dielectric strength of ≥ 50kV/mm, and are insulated with SF6 gas
Structural optimization
The 800kV cylindrical platform needs to adopt a multi-layer composite structure, such as a "metal insulation metal" sandwich design, to suppress electric field distortion
The 126kV cylindrical platform can adopt a single-layer insulation structure, but it is necessary to ensure that the creepage distance is ≥ 3.2mm (pollution level 2)
2、 Performance parameters and validation
Electrical performance
126kV parts have a power frequency withstand voltage of 230kV and a lightning impulse withstand voltage of 550kV; 800kV parts have a power frequency withstand voltage of 800kV and a lightning impulse withstand voltage of 1200kV
The 800kV drum platform needs to pass a 1200V DC/1-minute withstand voltage test with a leakage current of<1mA
Mechanical performance
The maximum deformation of the 126kV drum platform is &le; 0.45mm, and the interface stress is below 70MPa; The 800kV cylinder platform needs to pass a water pressure test at 1.5 times the rated pressure
3、 Typical Applications and Standards
Application scenarios
126kV tube platform is used for urban substations and industrial power supply systems (such as automobile manufacturing plants)
126-800kV tubular platform for ultra-high voltage transmission projects (such as Gas Insulated Switchgear GlS
Standard specifications
The design must comply with GB/T 11022-2020 "Common Technical Requirements for High Voltage Switchgear and Control Equipment Standards"
800kV components must meet the aging testing requirements for insulation materials in DL/T 246-2006 "Guidelines for Chemical Supervision"
4、 Manufacturing and Testing
Process requirements
The 126kV cylinder platform can use vacuum casting technology, while the 800kV cylinder platform requires 3D printing and gradient material composite technology
800kV parts require X-ray inspection for laminated defects
Environmental friendliness
800kV cylinder platform needs to reduce SF6 gas consumption by 15%, in line with the environmental protection requirements of the "Guiding Catalogue for the First Batch of Application Demonstrations of Key New Materials"

Note: Customization with drawings is available

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.