12KV 1250A SF6 gas filling cabinet electric spring operating mechanism circuit breaker mechanism

  • 12KV 1250A SF6 gas filling cabinet electric spring operating mechanism circuit breaker mechanism

Key attributes

Brand Switchgear parts
Model NO. 12KV 1250A SF6 gas filling cabinet electric spring operating mechanism circuit breaker mechanism
Rated voltage 12kV
Rated normal current 1250A
Rated frequency 50/60Hz
Series RNVD-12/B2X

Product descriptions from the supplier

Description

Instructions for use and operation

Inflatable cabinet mechanism Power transmission operation:  ①. Close the door; ②. Insert the handle into the grounding operation hole on the left side of the G mechanism, and operate clockwise to separate the locking/grounding of the lower door; ③. Insert the handle into the isolation operation hole on the right side of the G mechanism, and operate clockwise to close the isolation switch; ④. Insert the handle into the energy storage operation hole of the V mechanism and operate clockwise to store energy in the circuit breaker; ⑤. Press the closing button on the V mechanism to close the circuit breaker switch.  Power outage operation:  ①. Press the disconnect button on the V mechanism to open the circuit breaker switch; ②. Insert the handle into the isolation operation hole on the right side of the G mechanism, and operate counterclockwise to open the isolation switch; ③. Insert the handle into the grounding operation hole on the left side of the G mechanism, and operate counterclockwise to close the grounding switch; Only after the power outage and grounding are completed, can the lower door be opened.

Model description

Installation dimensions

FAQ
Q: What are the core functions of the 24kV gas cabinet circuit breaker operating mechanism?
A:
Its core functions focus on four dimensions: energy storage drive, safety protection, interlock coordination and scenario adaptation, which are the key guarantees for the reliable operation of 24kV gas cabinet circuit breakers: ① Energy storage and opening/closing drive: Through manual or electric energy storage, output stable mechanical force to drive the circuit breaker to complete opening and closing actions, ensuring reliable breaking and closing of the circuit; ② Safety protection: Equipped with over-torque protection, limit positioning and anti-misoperation functions, avoiding mechanism damage caused by excessive operation force and ensuring the circuit breaker is in the correct opening/closing position; ③ Interlock coordination: Cooperate with the cabinet door, isolator, earthing switch and other components to realize interlock control, preventing misoperations such as live opening/closing, closing with grounding and opening the cabinet door with electricity; ④ Scenario adaptation: Adapt to the sealed environment of gas cabinets, with strong corrosion resistance and moisture resistance, and match the installation interface and transmission stroke of 24kV circuit breakers; ⑤ Maintenance convenience: Simple structure, clear operation logic, and low difficulty in daily maintenance and fault handling.
Q: What is a 24kV gas cabinet circuit breaker operating mechanism?
A:
It is a core driving component specially matched with 24kV gas cabinet circuit breakers (including SF6 gas-insulated cabinets and vacuum cabinets), mainly used to provide stable mechanical energy for the circuit breaker to complete opening and closing actions, realizing safe switching and fault breaking of the 24kV medium-voltage power supply circuit. Its core characteristics include 3 points: ① Matching scenario: Integrally designed for 24kV gas cabinets, compact structure, adapting to the sealed space layout of the cabinet body and the installation requirements of the circuit breaker; ② Core functions: With energy storage, opening/closing drive, interlock protection and anti-misoperation functions, no external power supply is required for manual type, and electric type supports automatic control; ③ Application scope: Widely used in 24kV medium-voltage distribution systems such as urban power grids, industrial and mining enterprises, commercial parks, and ring main units, ensuring the safe and stable operation of the power supply network.
Q: What are the core functions of the 12kV gas cabinet circuit breaker electric operating mechanism?
A:
Its core functions focus on five dimensions: electric drive, intelligent control, safety protection, interlock coordination and scenario adaptation, which are the key guarantees for the intelligent and reliable operation of 12kV gas cabinet circuit breakers: ① Electric energy storage and drive: The motor automatically completes energy storage, outputs stable mechanical force to drive the circuit breaker to open and close, ensuring efficient and reliable circuit switching; ② Intelligent control: Support remote control (RS485/Modbus protocol), local button operation, and can feed back operation status (energy storage, opening/closing position) to the distribution control system in real time; ③ Safety protection: Equipped with over-torque protection, over-current protection, limit positioning and anti-misoperation functions, avoiding mechanism damage caused by excessive load and ensuring the circuit breaker is in the correct position; ④ Interlock coordination: Cooperate with cabinet door, isolator, earthing switch and other components to realize mechanical-electric interlock, preventing misoperations such as live opening/closing and opening the cabinet door with electricity; ⑤ Scenario adaptation: Adapt to the sealed and compact environment of 12kV gas cabinets, with strong corrosion resistance and moisture resistance, and stable operation under harsh working conditions.
Q: What is a 12kV gas cabinet circuit breaker electric operating mechanism?
A:
It is a dedicated electric drive component matched with 12kV gas cabinet circuit breakers (SF6 or vacuum type), mainly relying on motor energy storage and electric drive to complete the opening and closing actions of the circuit breaker, realizing intelligent switching and fault breaking of the 12kV medium-voltage power supply circuit. Its core characteristics include 3 points: ① Drive mode: Adopt electric motor drive, support local and remote control, no manual operation required, high automation level; ② Matching scenario: Integrally designed for 12kV gas cabinets, compact structure, adapting to the sealed space layout of the cabinet body and the installation requirements of the circuit breaker; ③ Core functions: With automatic energy storage, electric opening/closing, interlock protection, fault feedback and other functions, compatible with intelligent distribution system control signals. It is widely used in 12kV medium-voltage distribution systems such as urban power grids, industrial and mining enterprises, commercial parks, and intelligent ring main units.
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.