• 12kV 24kV 33kV Three Phases Transformer Pad Mounted HV/LV Plug-In Distribution Transformer
  • 12kV 24kV 33kV Three Phases Transformer Pad Mounted HV/LV Plug-In Distribution Transformer
12kV 24kV 33kV Three Phases Transformer Pad Mounted HV/LV Plug-In Distribution Transformer
discuss personally
Model
33kV Three Phases Tran
24kV Three Phases Tran
12kV Three Phases Tran
Basic info
Brand Rockwell
Model NO. 12kV 24kV 33kV Three Phases Transformer Pad Mounted HV/LV Plug-In Distribution Transformer
Rated voltage 24kV
Rated frequency 50/60Hz
Series H59
Product Detail

Description

With the development of the power industry, driven by urbanization,equipment intensification, technological advancements, and the urgent need for scenario adaptability, Rockwill has successfully developed the Top Mounted High/ Low Voltage Bushing Transformer (commonly known as the H59 earthing/Grounding Distribution Transformer), leveraging years of electrical design experience and integrating global advanced technical concepts.The H59 refers to a power transformer where both the high-voltage and low-voltage bushings are vertically installed on the top of the unit. This structural design allows all high- and low-voltage leads to be routed through the top, making it suitable for scenarios with strict lateral space constraints or requiring vertical busbar connections. It is a common type of oil-immersed transformer.

Service Environment

Temperature:

  • Maximum ambient temperature: +50℃;

  • Top oil temperature rise: +50℃

  • Average winding temperature rise: +55℃

Humidity: Daily average humidity 100%.

Above sea level: Maximum installation altitude: 1000m

Features

  • Reliable Grounding Protection: Specifically designed for grid grounding, it effectively suppresses fault currents to ensure system stability and personnel safety.

  • Outdoor Environment Adaptability: With a sealed pad-mounted structure, it is waterproof, dustproof, and corrosion-resistant, suitable for complex outdoor conditions like humidity and dust.

  • Space-Optimized Design: Pad-mounted installation saves ground space, ideal for land-intensive scenarios such as urban power distribution networks and commercial parks.

  • Three-Phase Balanced Power Supply: Supports three-phase four-wire systems, balancing power and lighting loads with high efficiency and minimal voltage fluctuation.

  • Convenient Maintenance: Centralized top bushing layout eliminates the need for complex opening during 检修 (maintenance), reducing downtime and costs.

  • High Compatibility: Adapts to HV/LV distribution networks, directly connecting to municipal or industrial power systems, and flexibly integrating with grounding compensation equipment.

Main Technical Parameters

Outline Drawing Reference

Reference Photos

Know your supplier
Rockwell
Wenzhou Rockwell Transformer Co., Ltd. It is a high - tech enterprise integrating R & D, production, sales, and service. It focuses on the manufacturing of power transformers and supporting equipment, and is committed to providing efficient, reliable, and energy - saving power transmission and distribution solutions for global customers. We can offer: •Distribution transformers and substations •Outdoor switchgears and breakers(recloser) •Switchgears and it’s components (GIS, RMU, VCB, SF6 CB) Market and Service: We always take customers as the orientation and provide customized services according to their requirements. Our products are exported to the Middle East, Africa, Northern Europe, South America, and many other countries and regions. Drive the future of electricity with technological innovation and become a leading global supplier of intelligent power equipment.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
60000m²
占位
占位
Documents
Public.
15kV 20kV 30kV Three Phases Transformer Pad Mounted HV/LV earthing/Grounding distribution transforme
Manual English
PDF
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!