13.2kV 14.4kV 19.92 kV 33kV 34.5 kV Single Phase Pole Mounted voltage regulator control for Precise output voltage regulation

  • 13.2kV 14.4kV 19.92 kV 33kV 34.5 kV Single Phase Pole Mounted voltage regulator control for Precise output voltage regulation

Key attributes

Brand ROCKWILL
Model NO. 13.2kV 14.4kV 19.92 kV 33kV 34.5 kV Single Phase Pole Mounted voltage regulator control for Precise output voltage regulation
Rated voltage 33kV
Rated frequency 50/60Hz
Rated capacity 200kVA
Series RVR

Product descriptions from the supplier

Description

Product Description

As a pioneer and the first source factory in China's voltage regulator industry, we have been deeply rooted in the sector for decades, accumulating profound technical expertise. Leveraging top-tier R&D capabilities and a mature manufacturing system, our products have gained widespread market trust with reliability and performance that far exceed industry standards.

The RVR-1 is a high-performance single-phase automatic voltage regulator for utility grids and industrial systems. It merges oil-immersed transformer reliability with advanced smart digital control, delivering precise, stable voltage regulation in harsh environments (remote rural grids, industrial parks, heavy-load facilities).

Its oil-immersed insulation ensures thermal stability, moisture resistance, and dielectric strength for long-term reliable operation in extreme conditions. Equipped with an intelligent digital control module, it offers real-time monitoring, automatic precision adjustment (multi-step tap switching), and remote communication (GPRS/GSM/Bluetooth) for easy configuration, fault diagnosis, and reduced on-site maintenance.

Ideal for mitigating voltage fluctuations from grid instability, load changes, or long-distance transmission, it safeguards sensitive equipment, improves power quality, and minimizes downtime—providing consistent, efficient power support.

Key Features

  • Precision Regulation:32-step tap changer with ±10% range (0.625% per step)

  • Smart Control:Real-time monitoring via GPRS/4G, Bluetooth 5.0, and cloud connectivity

  • Robust Protection:Overcurrent, undervoltage, surge, and arc fault protection

  • Durable Design:Stainless steel tank, vacuum-impregnated windings, and corrosion-resistant components

  • Easy Maintenance:Touchscreen HMI, self-diagnostics, and modular components

Technical Parameters

Available voltage ratings include 50Hz (6kV, 6.35kV, 11kV, 15kV, 22kV, 33kV) and 60Hz (7.62kV, 13.2kV 13.8kV, 14.4kV, 19.92kV, 34.5kV), with custom options available.

Parameter

Value

Model

RVR-1

Type

Single-phase, oil-immersed autotransformer

Voltage Range

Up to 34.5 kV

Frequency

50 Hz / 60 Hz

Regulation Range

±10%

Tap Steps

32 steps

Step Size

0.625% per step

Controller

RVR Smart Controller (GPRS/4G/Bluetooth)

Protection

Overcurrent, undervoltage, surge, arc fault

Cooling Method

Oil-immersed

50Hz

Voltage

(kV)

Current

(A)

Capacity

(kVA)

BIL (kV)

Power Frequency Withstand Voltage (kV)

Insulation Class

6/6.35

50

30/32

75/95

28

A

100

60/64

150

90/95

200

120/127

300

180/191

400

240/254

500

300/318

600

360/381

11

50

55

100

110

150

165

200

220

300

330

400

440

500

550

600

660

15

50

75

125/150

50

100

150

150

225

200

300

300

450

400

600

500

750

22

50

110

100

220

150

330

200

440

300

660

33

50

165

170/200

70

100

330

150

495

200

660

250

825

300

990

60Hz

Technical Specifications

  • Voltage Range:2,400V to 34,500V

  • Rating:60kV to 200kV

  • Frequency:50Hz/60Hz compatible

  • Regulation Range:±10% (32 steps)

  • Step Precision:625% per step

Applications

  • Utilities:Long feeder lines, weak grid support

  • Industry:Motor starting, process stability

  • Renewables:Solar/wind farm integration

  • Infrastructure:Data centers, hospitals

Why Choose RVR-1?

  • Higher Reliability:Industrial-grade components for 24/7 operation

  • Lower Losses:Optimized design reduces energy waste

  • Smart Monitoring:Remote diagnostics and predictive maintenance

  • Future-Ready:Supports grid modernization and IoT integration

 

Documentation Resource Library
Restricted
6kV to 34.5kV Single Phase Automatic Voltage Regulator Brochure
Catalogue
English
Consulting
Consulting
FAQ
Q: How does the Single Phase Pole Mounted Voltage Regulator achieve precise output voltage regulation?
A:

The regulator uses multi-step tap switching (e.g., 32-step/16-step) and an intelligent control module to real-time monitor grid voltage fluctuations. It automatically adjusts tap positions to stabilize output voltage within a ±10% (or ±20%) range (0.625%/2.5% per step), compensating for line drops/load changes. Ideal for overhead utility/industrial systems needing consistent voltage.

Q: What grid conditions and applications is the Single Phase Pole Mounted Voltage Regulator suitable for?
A:

Designed for 50Hz/60Hz single-phase grids (6kV-34.5kV), it’s pole-mounted for easy overhead line deployment—perfect for rural power networks, industrial parks, and remote load centers. It withstands harsh environments (extreme temps/humidity) and supports custom voltage ratings, fitting diverse utility/industrial precise regulation needs.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.