Key attributes

Brand ROCKWILL
Model NO. 13.2kV 13.8kV 14.4kV 19.92kV IEC Standard voltage regulator control compliant for Industrial Manufacturing Industry
Rated voltage 38kV
Rated frequency 50/60Hz
Rated capacity 500kVA
Series RVR

Product descriptions from the supplier

Description

Product Overview

As a pioneer and the first source factory in China's voltage regulator industry, we have been deeply rooted in the sector for decades, accumulating profound technical expertise. Leveraging top-tier R&D capabilities and a mature manufacturing system, our products have gained widespread market trust with reliability and performance that far exceed industry standards.

The RVR-1 is a single-phase, oil-immersed autotransformer-based feeder voltage regulator, designed to maintain stable voltage levels across medium voltage distribution lines. It integrates an advanced RVR controller, which continuously samples voltage and current signals via voltage and current transformers, enabling precise on-load tap changing to adapt to grid load variations. The system improves overall grid efficiency by adjusting line voltage up or down according to real-time demand.

This regulator features a motor-driven on-load tap changer (OLTC) with step control based on real-time voltage/current feedback, ensuring fast and reliable response to network fluctuations. It is ideally suited for both 50Hz and 60Hz distribution networks, with voltage ratings ranging from 2.4kV to 34.5kV.

Main Features

  • Voltage Regulation Flexibility:Features a ±10% regulation range (covering both boost and buck modes) with 32 precision step each calibrated to approximately 0.625% delivering ultra-accurate voltage control.

  • Intelligent RVR Control Unit:Comes with a proprietary advanced RVR controller (in-house developed), supporting GPRS/GSM and Bluetooth communication protocols for seamless remote monitoring and diagnostic functions.

  • Comprehensive Auto-Protection System:Integrates multi-layer protection against line faults, overloads, overcurrents, and undervoltages, coupled with automatic lock-out mechanisms to ensure the safety of both the equipment and the entire power system.

  • Flexible Voltage Configuration Options:Provides adjustable voltage setpoints, configurable step limits, customizable time delays between tap operations, and personalized operating parameter settings to cater to diverse application requirements.

Technical Parameters

Available voltage ratings include 50Hz (6kV, 6.35kV, 11kV, 15kV, 22kV, 33kV) and 60Hz (7.62kV, 13.2kV、13.8kV, 14.4kV, 19.92kV, 34.5kV). Customization is supported.

Parameter

Specification

Model No.

RVR-1

Rated Voltage

13.2kV 13.8kV 14.4kV 19.92kV 34.5kV

Phase

Single-phase

Mounting Type

Pole-mounted

Regulation Range

±10% (Boost/Buck)

Tap Steps

32 steps

Step Size

Approx. 0.625% per step

Transformer Type

Oil-immersed auto-transformer

Core Type

Core-type, “U” shape

Cooling Method

Oil-immersed

Controller

RVR Smart Controller (GPRS / GSM / Bluetooth)

Voltage Sensing

Current & voltage transformer sampling (CT/VT)

Protection Functions

Overcurrent, Undervoltage, Overload, Line Fault

Frequency

50 Hz / 60 Hz

Standards

IEC / ANSI / GB

Certification

ISO9001-2000

Enclosure Material

Stainless steel, corrosion-resistant

Color Options

Gray, Green, or Customized

 

Voltage

(kV)

Current

(A)

Capacity

(kVA)

BIL (kV)

Power Frequency Withstand Voltage (kV)

Insulation Class

7.62

50

38

60/75

20

A

100

76

150

114

219

167

328

250

438

333

546

416

13.8

50

69

95/125

38

100

138

150

207

200

276

300

414

400

552

14.4

50

72

100

144

200

288

300

432

400

576

19.92

50

100

170/200

70

100

200

167

333

200

400

335

667

34.5

50

165

100

330

150

495

200

660

Applications

Ideal for voltage regulation in:

  • Long rural or suburban feeder lines

  • Industrial zones with fluctuating load demand

  • Distribution systems requiring improved voltage stability

Documentation Resource Library
Restricted
6kV to 34.5kV Single Phase Automatic Voltage Regulator Brochure
Catalogue
English
Consulting
Consulting
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.