13.2kV 14.4kV 19.92 kV 33kV 34.5 kV Single Phase Pole Mounted voltage regulator control for Precise output voltage regulation

  • 13.2kV 14.4kV 19.92 kV 33kV 34.5 kV Single Phase Pole Mounted voltage regulator control for Precise output voltage regulation

Key attributes

Brand ROCKWILL
Model NO. 13.2kV 14.4kV 19.92 kV 33kV 34.5 kV Single Phase Pole Mounted voltage regulator control for Precise output voltage regulation
Rated voltage 33kV
Rated frequency 50/60Hz
Rated capacity 200kVA
Series RVR

Product descriptions from the supplier

Description

Product Description

As a pioneer and the first source factory in China's voltage regulator industry, we have been deeply rooted in the sector for decades, accumulating profound technical expertise. Leveraging top-tier R&D capabilities and a mature manufacturing system, our products have gained widespread market trust with reliability and performance that far exceed industry standards.

The RVR-1 is a high-performance single-phase automatic voltage regulator for utility grids and industrial systems. It merges oil-immersed transformer reliability with advanced smart digital control, delivering precise, stable voltage regulation in harsh environments (remote rural grids, industrial parks, heavy-load facilities).

Its oil-immersed insulation ensures thermal stability, moisture resistance, and dielectric strength for long-term reliable operation in extreme conditions. Equipped with an intelligent digital control module, it offers real-time monitoring, automatic precision adjustment (multi-step tap switching), and remote communication (GPRS/GSM/Bluetooth) for easy configuration, fault diagnosis, and reduced on-site maintenance.

Ideal for mitigating voltage fluctuations from grid instability, load changes, or long-distance transmission, it safeguards sensitive equipment, improves power quality, and minimizes downtime—providing consistent, efficient power support.

Key Features

  • Precision Regulation:32-step tap changer with ±10% range (0.625% per step)

  • Smart Control:Real-time monitoring via GPRS/4G, Bluetooth 5.0, and cloud connectivity

  • Robust Protection:Overcurrent, undervoltage, surge, and arc fault protection

  • Durable Design:Stainless steel tank, vacuum-impregnated windings, and corrosion-resistant components

  • Easy Maintenance:Touchscreen HMI, self-diagnostics, and modular components

Technical Parameters

Available voltage ratings include 50Hz (6kV, 6.35kV, 11kV, 15kV, 22kV, 33kV) and 60Hz (7.62kV, 13.2kV 13.8kV, 14.4kV, 19.92kV, 34.5kV), with custom options available.

Parameter

Value

Model

RVR-1

Type

Single-phase, oil-immersed autotransformer

Voltage Range

Up to 34.5 kV

Frequency

50 Hz / 60 Hz

Regulation Range

±10%

Tap Steps

32 steps

Step Size

0.625% per step

Controller

RVR Smart Controller (GPRS/4G/Bluetooth)

Protection

Overcurrent, undervoltage, surge, arc fault

Cooling Method

Oil-immersed

50Hz

Voltage

(kV)

Current

(A)

Capacity

(kVA)

BIL (kV)

Power Frequency Withstand Voltage (kV)

Insulation Class

6/6.35

50

30/32

75/95

28

A

100

60/64

150

90/95

200

120/127

300

180/191

400

240/254

500

300/318

600

360/381

11

50

55

100

110

150

165

200

220

300

330

400

440

500

550

600

660

15

50

75

125/150

50

100

150

150

225

200

300

300

450

400

600

500

750

22

50

110

100

220

150

330

200

440

300

660

33

50

165

170/200

70

100

330

150

495

200

660

250

825

300

990

60Hz

Technical Specifications

  • Voltage Range:2,400V to 34,500V

  • Rating:60kV to 200kV

  • Frequency:50Hz/60Hz compatible

  • Regulation Range:±10% (32 steps)

  • Step Precision:625% per step

Applications

  • Utilities:Long feeder lines, weak grid support

  • Industry:Motor starting, process stability

  • Renewables:Solar/wind farm integration

  • Infrastructure:Data centers, hospitals

Why Choose RVR-1?

  • Higher Reliability:Industrial-grade components for 24/7 operation

  • Lower Losses:Optimized design reduces energy waste

  • Smart Monitoring:Remote diagnostics and predictive maintenance

  • Future-Ready:Supports grid modernization and IoT integration

 

Documentation Resource Library
Restricted
6kV to 34.5kV Single Phase Automatic Voltage Regulator Brochure
Catalogue
English
Consulting
Consulting
FAQ
Q: How does the Single Phase Pole Mounted Voltage Regulator achieve precise output voltage regulation?
A:

The regulator uses multi-step tap switching (e.g., 32-step/16-step) and an intelligent control module to real-time monitor grid voltage fluctuations. It automatically adjusts tap positions to stabilize output voltage within a ±10% (or ±20%) range (0.625%/2.5% per step), compensating for line drops/load changes. Ideal for overhead utility/industrial systems needing consistent voltage.

Q: What grid conditions and applications is the Single Phase Pole Mounted Voltage Regulator suitable for?
A:

Designed for 50Hz/60Hz single-phase grids (6kV-34.5kV), it’s pole-mounted for easy overhead line deployment—perfect for rural power networks, industrial parks, and remote load centers. It withstands harsh environments (extreme temps/humidity) and supports custom voltage ratings, fitting diverse utility/industrial precise regulation needs.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.