13.2kV 13.8kV 14.4kV 19.92kV IEC Standard voltage regulator control compliant for Industrial Manufacturing Industry

  • 13.2kV 13.8kV 14.4kV 19.92kV IEC Standard voltage regulator control compliant for Industrial Manufacturing Industry

Key attributes

Brand ROCKWILL
Model NO. 13.2kV 13.8kV 14.4kV 19.92kV IEC Standard voltage regulator control compliant for Industrial Manufacturing Industry
Rated voltage 38kV
Rated frequency 50/60Hz
Rated capacity 500kVA
Series RVR

Product descriptions from the supplier

Description

Product Overview

As a pioneer and the first source factory in China's voltage regulator industry, we have been deeply rooted in the sector for decades, accumulating profound technical expertise. Leveraging top-tier R&D capabilities and a mature manufacturing system, our products have gained widespread market trust with reliability and performance that far exceed industry standards.

The RVR-1 is a single-phase, oil-immersed autotransformer-based feeder voltage regulator, designed to maintain stable voltage levels across medium voltage distribution lines. It integrates an advanced RVR controller, which continuously samples voltage and current signals via voltage and current transformers, enabling precise on-load tap changing to adapt to grid load variations. The system improves overall grid efficiency by adjusting line voltage up or down according to real-time demand.

This regulator features a motor-driven on-load tap changer (OLTC) with step control based on real-time voltage/current feedback, ensuring fast and reliable response to network fluctuations. It is ideally suited for both 50Hz and 60Hz distribution networks, with voltage ratings ranging from 2.4kV to 34.5kV.

Main Features

  • Voltage Regulation Flexibility:Features a ±10% regulation range (covering both boost and buck modes) with 32 precision step each calibrated to approximately 0.625% delivering ultra-accurate voltage control.

  • Intelligent RVR Control Unit:Comes with a proprietary advanced RVR controller (in-house developed), supporting GPRS/GSM and Bluetooth communication protocols for seamless remote monitoring and diagnostic functions.

  • Comprehensive Auto-Protection System:Integrates multi-layer protection against line faults, overloads, overcurrents, and undervoltages, coupled with automatic lock-out mechanisms to ensure the safety of both the equipment and the entire power system.

  • Flexible Voltage Configuration Options:Provides adjustable voltage setpoints, configurable step limits, customizable time delays between tap operations, and personalized operating parameter settings to cater to diverse application requirements.

Technical Parameters

Available voltage ratings include 50Hz (6kV, 6.35kV, 11kV, 15kV, 22kV, 33kV) and 60Hz (7.62kV, 13.2kV、13.8kV, 14.4kV, 19.92kV, 34.5kV). Customization is supported.

Parameter

Specification

Model No.

RVR-1

Rated Voltage

13.2kV 13.8kV 14.4kV 19.92kV 34.5kV

Phase

Single-phase

Mounting Type

Pole-mounted

Regulation Range

±10% (Boost/Buck)

Tap Steps

32 steps

Step Size

Approx. 0.625% per step

Transformer Type

Oil-immersed auto-transformer

Core Type

Core-type, “U” shape

Cooling Method

Oil-immersed

Controller

RVR Smart Controller (GPRS / GSM / Bluetooth)

Voltage Sensing

Current & voltage transformer sampling (CT/VT)

Protection Functions

Overcurrent, Undervoltage, Overload, Line Fault

Frequency

50 Hz / 60 Hz

Standards

IEC / ANSI / GB

Certification

ISO9001-2000

Enclosure Material

Stainless steel, corrosion-resistant

Color Options

Gray, Green, or Customized

 

Voltage

(kV)

Current

(A)

Capacity

(kVA)

BIL (kV)

Power Frequency Withstand Voltage (kV)

Insulation Class

7.62

50

38

60/75

20

A

100

76

150

114

219

167

328

250

438

333

546

416

13.8

50

69

95/125

38

100

138

150

207

200

276

300

414

400

552

14.4

50

72

100

144

200

288

300

432

400

576

19.92

50

100

170/200

70

100

200

167

333

200

400

335

667

34.5

50

165

100

330

150

495

200

660

Applications

Ideal for voltage regulation in:

  • Long rural or suburban feeder lines

  • Industrial zones with fluctuating load demand

  • Distribution systems requiring improved voltage stability

Documentation Resource Library
Restricted
6kV to 34.5kV Single Phase Automatic Voltage Regulator Brochure
Catalogue
English
Consulting
Consulting
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.