• IEC Rear Connector With Surge Arrester
  • IEC Rear Connector With Surge Arrester
  • IEC Rear Connector With Surge Arrester
IEC Rear Connector With Surge Arrester
discuss personally
Model
RW-HBLQ-51kV
RW-HBLQ-24kV
RW-HBLQ-17kV
Basic info
Brand Switchgear parts
Model NO. IEC Rear Connector With Surge Arrester
Rated voltage 51kV
Series RW-HBLQ
Product Detail

Summary
IEC Rear connector with surge arrester can provide reliable over-voltage protection for the electrical system. The external semi conductive Layers of screened type IEC Rear connector with surge arrester to ensure protect the operators when installation and maintenance,and also ensure the equipments in safetyAt the same time, its anti ultraviolet,anti-aging, waterproof, moisture-proof unique properties to ensure that the product in a harsh environment safe and reliable operation.

Standard packing
Body of surge arrester                                   Test report
Silicone grease、towels                               Bolt stud
Instruction Manual                                         Dust cap
Conductive rod                                                Conformity certificat

Technical specification

Item

Units

RW-HBLQ-17/45

RW-HBLQ-17/50

RW-HBLQ-10/27

RW-HBLQ-10/30

RW-HBLQ-13/36

Product model

-

RW-HBLQ-17/45

RW-HBLQ-17/50

RW-HBLQ-10/27

RW-HBLQ-10/30

RW-HBLQ-13/36

Nominal voltage of a system

kV

10

10

6

6

10

Rated voltage of arrester

kV

17

17

10

10

13

Continuous running voltage

kV

13.6

13.6

8

8

10.4

Nominal discharge current In

kA

5

5

5

5

5

Dc 1mA reference voltage

kV

≥24

≥25

≥14.4

≥15

≥19.3

0.75U1mA leakage current

μA

≤10

≤10

≤10

≤10

≤10

Steep current impulse residual voltage

kV

≤57.8

≤57.5

≤31

≤34.6

≤41.3

Lightning impulse residual voltage

kV

≤45

≤50

≤27

≤30

≤36

Operating impulse residual voltage

kV

≤35

≤42.5

≤23

≤25.6

≤30.7

Partial discharge at 15kV

pC

≤10

≤10

≤10

≤10

≤10

2ms square wave impulse current tolerance

kA

150

150

150

150

150

High current shock tolerance

kA

65

65

65

65

65

Units RW-HBLQ-26/66 RW-HBLQ-32/85 RW-HBLQ-34/85 RW-HBLQ-34/90  
Product model - RW-HBLQ-26/66 RW-HBLQ-32/85 RW-HBLQ-34/85 RW-HBLQ-34/90
Nominal voltage of a system kV 20 20 20 20
Rated voltage of arrester kV 26 32 34 34
Continuous running voltage kV 20.8 25.6 27.2 27.2
Nominal discharge current In kA 5 5 5 5
Dc 1mA reference voltage kV ≥37 ≥47 ≥48 ≥50
0.75U1mA leakage current μA ≤10 ≤10 ≤10 ≤10
Steep slope impact residual voltage kV ≤76 ≤95 ≤95 ≤104
Lightning impulse residual voltage kV ≤66 ≤85 ≤85 ≤90
Operating impulse residual voltage kV ≤56 ≤75 ≤75 ≤80
25.4kV Partial discharge pC ≤10 ≤10 ≤10 ≤10
2ms square wave impact current tolerance A 150 150 150 150
High current shock tolerance kA 65 65 65 65
Item Units RW-HBLQ-51/134/400 RW-HBLQ-51/134/600 RW-HBLQ-51/134/800
Product model - RW-HBLQ-51/134/400 RW-HBLQ-51/134/600 RW-HBLQ-51/134/800
Nominal voltage of a system kV 35 35 35
Rated voltage of arrester kV 51 51 51
Continuous running voltage kV 40.8 40.8 40.8
Nominal discharge current kA 5 5 5
Dc 1mA reference voltage kV ≥73 ≥73 ≥73
0.75U1mA leakage current μA ≤10 ≤10 ≤10
Steep slope impact residual voltage kV ≤154 ≤154 ≤154
Lightning impulse residual voltage kV ≤134 ≤134 ≤134
Operating impulse residual voltage kV ≤114 ≤114 ≤114
Partial discharge at 45kV pC ≤10 ≤10 ≤10
2ms square wave impact current tolerance A 400 600 800
High current shock tolerance kA 100 100 100

 

Note: When Selection,Please indicate the lightning impulse residual voltage value.

 

Know your supplier
Switchgear parts
VoltEdge Solutions​​ specializes in manufacturing premium ​​MV switchgear accessories​​ for global power distribution systems. Our product range includes circuit breaker modules, disconnector spares, and surge arrestors, engineered for ​​24kV+ substations​​ and renewable energy plants. With ISO-certified production and 24/7 technical support, we ensure ​​reliability, compliance​​ with IEC standards, and rapid global supply.
Main Categories
Electrical fittings/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Key Points of Online Monitoring Technology for Zinc Oxide Surge Arresters
Key Points of Online Monitoring Technology for Zinc Oxide Surge Arresters
1 Architecture of the Online Monitoring System for Zinc Oxide Surge ArrestersThe online monitoring system for zinc oxide surge arresters comprises three layers: the station control layer, bay layer, and process layer.Station Control Layer: Includes a monitoring center, a Global Positioning System (GPS) clock, and a B - code clock source.Bay Layer: Consists of online monitoring Intelligent Electronic Devices (IEDs).Process Layer: Features monitoring terminals for Potential Transformers (PTs) and
Oliver Watts
07/30/2025
Improvement and Application of the Test Device for Surge Arrester Online Monitor
Improvement and Application of the Test Device for Surge Arrester Online Monitor
1 Significance of Surge Arrester Online Monitors1.1 Enhance Power System Safety, Reduce Lightning DamageDuring lightning strikes, surge arresters play a core role in discharging overvoltage. Online monitors ensure arrester stability, detect potential faults in real - time, and trigger alarms for timely intervention—effectively reducing lightning - induced damage to power equipment and systems, and maintaining stable operation.1.2 Real - Time Status Monitoring, Improve Maintenance Efficienc
Edwiin
07/30/2025
Design of Monitoring System for Surge Arrester in GIS Cubicle of 10kV Power Distribution System for High-Speed Railways
Design of Monitoring System for Surge Arrester in GIS Cubicle of 10kV Power Distribution System for High-Speed Railways
1 Research BackgroundMetal - oxide surge arresters, sealed in cabinets, bear system voltage continuously, risking aging failures, even breakdowns/explosions causing electrical fires. Thus, regular inspection/maintenance is needed. Traditional 3–5 - year - cycle detection (power cut, arrester removal for tests; reinstallation if replaced) poses safety risks and faces space/environment - based standard - grasping difficulties.2 Monitoring Principle of 10kV GIS Cabinet Surge ArresterTo ensure
Dyson
07/30/2025
Can a power transformer designed for 50Hz operate normally at a frequency of 60Hz?
Can a power transformer designed for 50Hz operate normally at a frequency of 60Hz?
Can a 50Hz-Designed Power Transformer Operate on 60Hz Grid?If a power transformer is designed and built for 50Hz, can it run on a 60Hz grid? If so, how do its key performance parameters change?Key Parameter ChangesShort-Circuit Impedance:For a given transformer (same voltage and capacity), short-circuit impedance is proportional to frequency. Thus, a 50Hz-designed unit operating at 60Hz sees a 20% increase—higher frequency intensifies alternating leakage field opposition to current.No-Load
Vziman
07/29/2025
What are the common faults of overhead cables?
What are the common faults of overhead cables?
Overhead cables, due to their exposure to external environments, are subject to various influences that can lead to different types of faults. Below are some common types of faults in overhead cables and their causes:1. Mechanical DamageCaused by external forces such as falling trees, vehicle collisions, or construction accidents.Prolonged vibrations or swinging can also cause material fatigue in cables.2. Weather-Related FaultsLightning Strikes: Direct hits or nearby lightning strikes can cause
Felix Spark
07/29/2025
An Innovative Photoelectromagnetic Cable Eccentricity Measuring Instrument
An Innovative Photoelectromagnetic Cable Eccentricity Measuring Instrument
A core challenge in online cable eccentricity measurement is the cable’s high - speed motion. This requires non - contact measurement equipment that can handle cable jitter. X - ray cable eccentricimeters, based on optical transmission imaging, measure multi - layer contour dimensions to calculate the geometric center of conductors relative to insulation eccentricity. However, they have drawbacks: slow measurement speed (only a few times per second), increased errors from cable jitter, and
Oliver Watts
07/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!