• 2500kVA 11kV Oil-immersed distribution transformer three-phase
  • 2500kVA 11kV Oil-immersed distribution transformer three-phase
  • 2500kVA 11kV Oil-immersed distribution transformer three-phase
2500kVA 11kV Oil-immersed distribution transformer three-phase
discuss personally
Model
S-11KV-2500KVA
Basic info
Brand Vziman
Model NO. 2500KVA 11KV Oil-immersed distribution transformer three-phase
Rated voltage 11kV
Rated capacity 2500kVA
Series S
Product Detail

Description:

Oil immersed transformer ,use our company special calculation and validation procedures to make sure theperformance of products. superior process equipment ,elaborate materialselecting and efficient manufacturing make the transformer have smallvolume,light weight,low loss,low partial discharge,low noise characteristics.

The product is stable,reliable,economic, environmental protection. lt can beapplied to many places such as power plants,transformer substation ,largeindustrial mining and petrochemical enterprise and so on.

Features:

  • Ultralow no-load loss

  • Energy saving and great power consuming efficiency

  • Copper coil winding, strong short circuit resistance ability

  • Dyn11 coil connection decrease the influences of harmonic wave

  • Fully sealed structure for maintenance free

  • Slow insulation aging & longer serving life

Parameters:

Oil-immersed distribution transformer three-phase

Model NO.

S-2500-11

Product classification

Distribution transformer

Rated capacity

2500kVA

Primary voltage

11kV

Secondary voltage

0.4kV

Number of phase

3

Number of winding

2

Rated frequency

50Hz

Tap changer

OCTC

Tap range

±2×2.5%

Vector group

Yd11400v delta 11kv star 

Cooling system

ONAN

No-load loss

3800+10%

Load loss

19000+10%

Standard

IEC60076

Impedance

4.75±10%

Basic insulation level

75/28kv

Winding material ( H.V & L.V)

Copper

The way the bushing appears

Porcelain

Power frequency withstand voltage

——

Lightning impulse

——

The temperature rise—Winding

——

The temperature rise --Top oil

——

Tank color

——

Creepage distance

——

Environmental requirement

——

Transformer structure

Sealed

External dimensions:

企业微信截图_17240297972200.png

Size

2425mm×1520mm×2170mm

Weight

3080KG


Environmental requirement:

Max. ambient temperature


Altitude


Product show:      

   

Yawei 160kVA 10kv Hot Selling Oil-Filled Three-Phase Distribution Transformer with UL

What are the structural characteristics of oil-immersed distribution transformers?

Definitions and Characteristics:

  • Oil-Immersed: It means that the iron core and windings of the transformer are immersed in insulating oil, and the oil plays a dual role of cooling and insulation.

  • Distribution Transformer: It is used to convert high-voltage electrical energy into low-voltage electrical energy for users' use.
    Three-Phase: Usually, it means that the transformer has three independent windings and is applicable to three-phase alternating current systems.

Structural Characteristics:

  • Iron Core: It is usually made by laminating high-quality silicon steel sheets, featuring low loss and low noise.

  • Windings: The primary winding and the secondary winding are usually wound with copper wires, possessing excellent electrical conductivity and mechanical strength.

  • Insulating Oil: The inside of the transformer is filled with insulating oil. The oil not only plays a cooling role but also provides good insulation performance.

  • Oil Tank: The iron core and windings of the transformer are installed in the oil tank. The oil tank is usually made of steel plates and has good sealing performance.

  • Cooling System: Depending on the power level, oil-immersed transformers can adopt natural cooling, air cooling or forced oil circulation cooling methods.

  • Bushing: The high-voltage and low-voltage leads are led out through the bushing. The bushing has good insulation performance to ensure safe operation.


Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec