• 27kV MV outdoor Auto Circuit vacuum recloser
27kV MV outdoor Auto Circuit vacuum recloser
$5000.00
Model
RCW-E27G/1250-25
RCW-E27G/800-20C
RCW-E27G/800-20
RCW-E27G/630-16C
RCW-E27G/630-16
RCW-E27G/400-12.5C
RCW-E27G/400-12.5
Basic info
Brand ROCKWILL
Model NO. 27kV MV outdoor Auto Circuit vacuum recloser
Rated voltage 27kV
Rated normal current 1250A
Rated short circuit breaking current 25kA
Power frequency withstand voltage 70kV/min
Rated lightning impulse voltage 150kV
manual closing No
Mechanical lock No
Series RCW
Product Detail

Description:

The RCW   series automatic circuit reclosers can use on overhead distribution lines as well as distribution substation applications for allvoltage classes 11kV up to 38kV at 50/60Hz power system.  and it’s rated current can reach 1250A.The RCW   series automatic circuit reclosers integrates the functions of control, protection, measurement, communication, fault detection, on-line monitoring of closing or opening.The RCW   series vacuum recloser is mainly combined with integration terminal, current transformer, permanent magnetic actuator and it’s recloser controller.

Features:

  • Optional grades available in rated current range.

  • With optional relay protection and logic for user selection.

  • With optional communication protocols and I/O ports for users to choose.

  • PC software for controller testing, setup, programming, updates.

Parameters:

image.png

image.png

External dimensions:

企业微信截图_17103058136732.png


Environmental requirement:

image.png

Product show:

正方形最新环氧聚脂带手和.png

 What are the key points for the selection of outdoor vacuum reclosers?

  • System Parameter Matching: Choose a recloser that matches the rated voltage, rated current, and short-circuit current levels of the power system. Ensure that the rated voltage of the recloser is equal to or higher than the system voltage, the rated current meets the requirements of the line load current, and the rated short-circuit breaking and making currents are greater than the maximum possible short-circuit current in the system.

  • Reclosing Performance Requirements: Consider the specific requirements of the power system for the reclosing function, such as the number of reclosures, reclosing time intervals, and reclosing success rate. Based on different application scenarios and power supply reliability requirements, select a recloser with appropriate reclosing performance. For example, for critical power supply lines, a recloser with a higher number of reclosures and flexible reclosing time intervals may be required.

  • Type of Operating Mechanism: Choose an appropriate operating mechanism based on actual needs. Spring-operated mechanisms are suitable for outdoor environments where high reliability is required and maintenance conditions are relatively poor. Permanent magnet-operated mechanisms are better suited for applications requiring high action speed and frequent operations.

  • Environmental Adaptability: Given the harsh conditions of outdoor environments, consider the environmental adaptability of the recloser. This includes weather resistance, pollution resistance, and water and dustproof performance. Selecting a recloser with good environmental adaptability ensures stable performance during long-term outdoor operation.

  • Brand and Quality: Choose well-known brands and high-quality recloser products. These products have strict quality control systems in design, manufacturing, and testing, ensuring the performance and reliability of the product. Additionally, good after-sales service is an important factor to consider when choosing a brand, as it ensures timely resolution of issues that may arise during equipment operation.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Can a power transformer designed for 50Hz operate normally at a frequency of 60Hz?
Can a power transformer designed for 50Hz operate normally at a frequency of 60Hz?
Can a 50Hz-Designed Power Transformer Operate on 60Hz Grid?If a power transformer is designed and built for 50Hz, can it run on a 60Hz grid? If so, how do its key performance parameters change?Key Parameter ChangesShort-Circuit Impedance:For a given transformer (same voltage and capacity), short-circuit impedance is proportional to frequency. Thus, a 50Hz-designed unit operating at 60Hz sees a 20% increase—higher frequency intensifies alternating leakage field opposition to current.No-Load
Vziman
07/29/2025
What are the common faults of overhead cables?
What are the common faults of overhead cables?
Overhead cables, due to their exposure to external environments, are subject to various influences that can lead to different types of faults. Below are some common types of faults in overhead cables and their causes:1. Mechanical DamageCaused by external forces such as falling trees, vehicle collisions, or construction accidents.Prolonged vibrations or swinging can also cause material fatigue in cables.2. Weather-Related FaultsLightning Strikes: Direct hits or nearby lightning strikes can cause
Felix Spark
07/29/2025
An Innovative Photoelectromagnetic Cable Eccentricity Measuring Instrument
An Innovative Photoelectromagnetic Cable Eccentricity Measuring Instrument
A core challenge in online cable eccentricity measurement is the cable’s high - speed motion. This requires non - contact measurement equipment that can handle cable jitter. X - ray cable eccentricimeters, based on optical transmission imaging, measure multi - layer contour dimensions to calculate the geometric center of conductors relative to insulation eccentricity. However, they have drawbacks: slow measurement speed (only a few times per second), increased errors from cable jitter, and
Oliver Watts
07/29/2025
An Intelligent Device for Insulation Restoration of Low-Voltage Overhead Cables
An Intelligent Device for Insulation Restoration of Low-Voltage Overhead Cables
1. Current Situation and ProblemsLow - voltage overhead cables often suffer insulation damage. Urbanization and infrastructure construction expose them to complex environments (construction, severe weather like strong winds/rains causing scratches or impacts, animal damage), easily breaking insulation layers. Long - term operation also degrades insulation due to aging, corrosion, and prolonged sunlight—e.g., cables in old communities age and crack, raising failure risks.Existing restoratio
Dyson
07/29/2025
Research on Cable Laying and Wiring Construction Technology of Photovoltaic Power Station
Research on Cable Laying and Wiring Construction Technology of Photovoltaic Power Station
1 Research on Cable Laying and Wiring Construction Technology of Photovoltaic Power Station1.1 Data CollectionBefore constructing the BIM model for cable laying, it is necessary to deeply master the detailed parameters of the involved equipment specifications, materials used in construction, and site conditions, aiming to improve the accuracy of model construction. To ensure that the BIM model can accurately reflect the actual situation of the construction site, the core lies in accurately colle
Echo
07/29/2025
Cable Detection and Analysis of Integrated Wiring System in Intelligent Buildings
Cable Detection and Analysis of Integrated Wiring System in Intelligent Buildings
The integrated wiring system of intelligent buildings, as the core carrier of information transmission, functions like a "nervous system." It connects signals such as voice, data, and images, enabling device interconnection and efficient information transmission. Cable detection is a key link to ensure system performance and information security, focusing on index detection, problem troubleshooting, and response measures.1. Core Cable Detection Indicators1.1 Appearance and Identification Verific
Oliver Watts
07/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!