• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


550kV single-phase bowl insulator

  • 550kV single-phase bowl insulator

Key attributes

Brand Switchgear parts
Model NO. 550kV single-phase bowl insulator
Rated voltage 550kV
Series RN

Product descriptions from the supplier

Description

The 550kV single-phase bowl insulator is the core insulation component in gas insulated metal enclosed switchgear (GIS), and its design needs to meet the requirements of electric field uniformity, mechanical strength, and environmental protection under high voltage levels. The following is a comprehensive technical analysis based on the latest research:
1、 Design optimization and performance improvement
Geometry optimization
Adopting a contour design of "thick on both sides and thin in the middle", the maximum electric field strength along the concave surface is reduced by 25.4%, and the deformation is reduced by 29.9%
Optimize thickness variables (H ₁, H ₂, etc.) and contour variables (C ₁ ₂, C ₁ ∝, etc.) through genetic algorithm to balance electrical and mechanical performance
Application of dielectric gradient materials
Introducing a high dielectric constant region near the grounding flange (such as titanium dioxide filled epoxy resin) significantly improves electric field distortion and reduces SF6 gas usage by 15%
3D printing combined with casting technology achieves dielectric non-uniform structure, increasing flashover voltage by 13.8%
2、 Key parameters and experimental verification
Electrical performance
Power frequency withstand voltage 230kV, lightning impulse withstand voltage 550kV, local discharge capacity ≤ 5pC
After optimization, the flashover voltage of the insulator is increased by 13.6% compared to the conventional structure, and can still be increased by 6.7% in the presence of metal foreign objects
Mechanical performance
The maximum deformation is reduced to 0.45mm, and the interface stress is lower than the material limit (70MPa)
Verify the reliability of the structure through a water pressure failure test (1.5 times the rated pressure)
3、 Manufacturing process and environmental friendliness
Advanced technology
Using aluminum oxide/photosensitive resin 3D printing low dielectric constant body (ε=3.98-4.20), high dielectric constant area (ε=11.32-14.58) vacuum casting, no aluminum ring design simplifies the structure, reducing the risk of SF6 gas leakage
Environmental benefits
The usage of epoxy composite materials decreased by 6.1%, and the usage of SF6 gas decreased by 15%
4、 Typical application scenarios
Ultra high voltage transmission: such as 550kV GIS equipment, suitable for compact substations or high-altitude environments
GIL system: Optimized bowl insulators can reduce the maximum electric field in gas areas by 13.6%, improving the reliability of GIL operation

Note: Customization with drawings is available

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.