• 75 kVA Single Phase Pole Mounted Transformer
  • 75 kVA Single Phase Pole Mounted Transformer
75 kVA Single Phase Pole Mounted Transformer
discuss personally
Model
DR11-75/11
Basic info
Brand Vziman
Model NO. 75 kva Single Phase Pole Mounted Transformer
Rated voltage 11kV
Rated capacity 75kVA
Series Single Phase Pole Mounted Transformer
Product Detail

Product overview: 

  •  WONE is a professional manufacturer of distribution transformers with 10 years of manufacturing experience.

  • The single-phase Pole-Mounted transformers designed and produced are usually used for urban and rural power distribution.

  • Input voltages:11kv, 12.4kv, 13.2kv, 13.8kv and 34.5kv; Output voltage:240 / 480v, 120 / 240V, etc. 

  • Executive Standards: IEEE C57, ANSI C57, IEC60076 .

Leading technology:

  •  Unique winding technology to improve lightning resistance.

  •   Small magnetic leakage, high mechanical strength, strong short circuit resistance.

  • Iron core 45° full oblique joint step laminated structure .

The shell:

  • Mitsubishi laser cutting machine and CNC punching, reducing, folding and other equipment to ensure the accuracy of processing.

  • ABB robot automatic welding, laser detection, to avoid leakage, qualified rate of 99.99998%.

  • Electrostatic spray treatment, 50 years of paint (coating corrosion resistance within 100h, hardness ≥0.4).

  • Cylindrical fully sealed construction with self-sealing manual pressure relief valve (according to ANSI specification).

  • Standard NEMA hanger bracket (each device includes pole support bracket plate).

  • Fully sealed structure, maintenance-free, normal operation life of more than 30 years.

The iron core:

  • The core material is high quality cold rolled grain oriented silicon steel sheet with mineral oxide insulation (from Baowu Steel Group China).

  • Minimize loss level, no-load current and noise by controlling the cutting and stacking process of silicon steel sheet.

winding:

  •  Low voltage windings are made of high quality cable paper wrapped wire.

  • High voltage windings are made of high quality polyurethane enamelled round copper wire.

  • Interlayer insulation using dot adhesive paper, so that the coil bonding into a fixed unit, with excellent insulation resistance.

  • Transformer structure is reliable during normal operation and transportation.

High quality material:

  • Baowu Steel Group production of silicon steel sheet.

  • High quality anaerobic copper from China.

  • CNPC (Kunlun Petroleum) High quality transformer oil (25#).

Other:

  •  High strength polymer low pressure casing or high and low pressure porcelain casing.

  • Equipped with ring type full copper tinned terminal.

  •  Install limited current fuses and arresters.

Ordering instructions:

  •  Main parameters of transformer (voltage, capacity, loss and other main parameters) .

  • Transformer use environment (altitude, temperature, humidity, place, etc) .

  • Other customized requirements (tap switch, color, oil pillow, etc) .

  • The minimum order quantity is 1 set, global delivery within 7 days .

  •  The normal delivery period is 30 days, with fast delivery worldwide .

How does the oil-immersed transformer work as a fire protection device?


Protection Devices:
Gas Relay:

When a fault occurs inside the transformer, such as local overheating, electric arc discharge, etc., the insulating oil will decompose and produce gas. The gas relay is installed in the connecting pipeline between the oil tank and the conservator of the oil - immersed transformer.
Once a certain amount of gas is detected, the gas relay will act. It can take different measures according to the severity of the fault. For example, when the light - gas action occurs, an alarm signal will be sent to remind the operation personnel to check; when the heavy - gas action occurs, the power supply of the transformer will be directly cut off to prevent the fault from further expanding and causing a fire.

Fire Isolation Measures:
In the installation environment of the transformer, fire isolation facilities are usually set up. For example, in a substation, an oil - immersed transformer may be installed in an independent fire - proof compartment.
The fire - proof compartment is constructed with fire - resistant materials, such as fire - bricks, fire - proof coatings, etc. These materials can prevent the spread of fire for a certain period of time (such as 1 - 2 hours, depending on the material properties), buying time for firefighters to come and put out the fire.
In addition, fire - proof dikes may be set up around the transformer to prevent the large - area fire caused by the outflow of insulating oil after the rupture of the transformer's oil tank. The fire - proof dikes can limit the leaked oil within a certain range
.


Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!