75 kVA Single Phase Pole Mounted Transformer

  • 75 kVA Single Phase Pole Mounted Transformer

Key attributes

Brand Vziman
Model NO. 75 kva Single Phase Pole Mounted Transformer
Rated voltage 11kV
Rated capacity 75kVA
Series Single Phase Pole Mounted Transformer

Product descriptions from the supplier

Description

Product overview: 

  •  WONE is a professional manufacturer of distribution transformers with 10 years of manufacturing experience.

  • The single-phase Pole-Mounted transformers designed and produced are usually used for urban and rural power distribution.

  • Input voltages:11kv, 12.4kv, 13.2kv, 13.8kv and 34.5kv; Output voltage:240 / 480v, 120 / 240V, etc. 

  • Executive Standards: IEEE C57, ANSI C57, IEC60076 .

Leading technology:

  •  Unique winding technology to improve lightning resistance.

  •   Small magnetic leakage, high mechanical strength, strong short circuit resistance.

  • Iron core 45° full oblique joint step laminated structure .

The shell:

  • Mitsubishi laser cutting machine and CNC punching, reducing, folding and other equipment to ensure the accuracy of processing.

  • ABB robot automatic welding, laser detection, to avoid leakage, qualified rate of 99.99998%.

  • Electrostatic spray treatment, 50 years of paint (coating corrosion resistance within 100h, hardness ≥0.4).

  • Cylindrical fully sealed construction with self-sealing manual pressure relief valve (according to ANSI specification).

  • Standard NEMA hanger bracket (each device includes pole support bracket plate).

  • Fully sealed structure, maintenance-free, normal operation life of more than 30 years.

The iron core:

  • The core material is high quality cold rolled grain oriented silicon steel sheet with mineral oxide insulation (from Baowu Steel Group China).

  • Minimize loss level, no-load current and noise by controlling the cutting and stacking process of silicon steel sheet.

winding:

  •  Low voltage windings are made of high quality cable paper wrapped wire.

  • High voltage windings are made of high quality polyurethane enamelled round copper wire.

  • Interlayer insulation using dot adhesive paper, so that the coil bonding into a fixed unit, with excellent insulation resistance.

  • Transformer structure is reliable during normal operation and transportation.

High quality material:

  • Baowu Steel Group production of silicon steel sheet.

  • High quality anaerobic copper from China.

  • CNPC (Kunlun Petroleum) High quality transformer oil (25#).

Other:

  •  High strength polymer low pressure casing or high and low pressure porcelain casing.

  • Equipped with ring type full copper tinned terminal.

  •  Install limited current fuses and arresters.

Ordering instructions:

  •  Main parameters of transformer (voltage, capacity, loss and other main parameters) .

  • Transformer use environment (altitude, temperature, humidity, place, etc) .

  • Other customized requirements (tap switch, color, oil pillow, etc) .

  • The minimum order quantity is 1 set, global delivery within 7 days .

  •  The normal delivery period is 30 days, with fast delivery worldwide .

How does the oil-immersed transformer work as a fire protection device?


Protection Devices:
Gas Relay:

When a fault occurs inside the transformer, such as local overheating, electric arc discharge, etc., the insulating oil will decompose and produce gas. The gas relay is installed in the connecting pipeline between the oil tank and the conservator of the oil - immersed transformer.
Once a certain amount of gas is detected, the gas relay will act. It can take different measures according to the severity of the fault. For example, when the light - gas action occurs, an alarm signal will be sent to remind the operation personnel to check; when the heavy - gas action occurs, the power supply of the transformer will be directly cut off to prevent the fault from further expanding and causing a fire.

Fire Isolation Measures:
In the installation environment of the transformer, fire isolation facilities are usually set up. For example, in a substation, an oil - immersed transformer may be installed in an independent fire - proof compartment.
The fire - proof compartment is constructed with fire - resistant materials, such as fire - bricks, fire - proof coatings, etc. These materials can prevent the spread of fire for a certain period of time (such as 1 - 2 hours, depending on the material properties), buying time for firefighters to come and put out the fire.
In addition, fire - proof dikes may be set up around the transformer to prevent the large - area fire caused by the outflow of insulating oil after the rupture of the transformer's oil tank. The fire - proof dikes can limit the leaked oil within a certain range
.


Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 10000m² Total staff: 300 Highest Annual Export(usD): 150000000
Workplace: 10000m²
Total staff: 300
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Choosing Vizman Distribution Transformers: Innovative Customization to Meet Diverse Power Needs
    Distribution transformers are the heart of local electricity distribution systems. They step down voltage, enabling safe and efficient power supply to homes and businesses.At Vizman Electric Power Technology Co., Ltd., we understand the critical role of distribution transformers in the energy ecosystem. That's why we specialize in manufacturing high-quality distribution transformers, providing tailored solutions to meet diverse energy needs.1.Solutions Offered by Vizman Electric Power Technology
    04/16/2025
  • SF6 Circuit Breaker Solutions in High-Voltage Power Systems: A Case Study of VZIMAN Company
    1. Challenges in High-Voltage Power Systems1.1 High-voltage power systems, as the core of power transmission, face critical challenges: Equipment Performance Limits: With increasing voltage levels (e.g., 500kV and above), traditional circuit breakers struggle to meet high breaking capacities (over 40kA) and rapid insulation recovery requirements. Overvoltage Risks: Switching capacitive loads (e.g., capacitor banks) may cause reignition, leading to dangerous overvoltages. Poor Environmental Adapt
    05/13/2025
  • VZIMAN Company SF6 Circuit Breaker Solutions for Renewable Energy Grid Integration
    1. Current Challenges in Renewable Energy Grid Integration1.1 Grid Frequency Fluctuations and Stability IssuesThe intermittency and variability of renewable energy sources (e.g., wind and solar) lead to frequent grid frequency changes. Traditional circuit breakers struggle to respond rapidly to such dynamic loads, potentially causing equipment damage or regional blackouts. For instance, during sudden drops in wind power or abrupt solar output fluctuations, the grid must isolate faults within mil
    05/13/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.