Center Vee Switch Unitized

  • Center Vee Switch Unitized

Key attributes

Brand ROCKWILL
Model NO. Center Vee Switch Unitized
Rated voltage 145kV
Rated normal current 3000A
Series AGCH5VU

Product descriptions from the supplier

Description

The Center Vee Switch Unitized is a high-voltage switching device with a double-column V-type structure design. It is mainly used for circuit switching and electrical isolation under no-load conditions in power systems, and has significant advantages especially in scenarios such as wind power and substations.

Features:

  • Fully Assembled and adjusted prior to shipment for quick installation

  • 8.3kV – 145kV

  • 3000A – 4000A

  • Rotating Blade Mechanisn

  • Reverse Loop Contacts

  • Laminated Shunt Hinge

  • Double Row Stainless Steel Bearing

  • Compatible with Turner TECORupter Interrupter Attachments

FAQ for
Q: How to Select Suitable Disconnectors Based on Altitude?
A:

In high-altitude areas, due to thin air, insulation distances need to be appropriately increased. Therefore, the following points should be considered during selection:

  • Rockwill Electric: DS7B-800D/5000, custom-designed for high-altitude applications, offers strong corrosion resistance and durability, adapts to complex outdoor environments, and features user-friendly operation with reliable safety interlock design.

  • Pinggao Electric: GW46-1100/6300, an ultra-high voltage (UHV) level product capable of providing sufficient insulation margin.

  • China XD Electric: GW47-1100/6300, also suitable for UHV environments and tested for plateau adaptability.

  • Siyuan Electric: GW5-G-252D/2000, though not at the UHV level, its improved design enhances performance under high-altitude conditions.

Comparison Points:

  • Insulation Distance: UHV-level models like GW46 and GW47 provide larger insulation distances, making them more suitable for high-altitude applications.

  • Altitude Correction: For non-UHV level products, it is necessary to refer to the altitude correction factors of specific models to ensure compliance with on-site conditions.

 
Q: What type of disconnector should be selected for projects in coastal areas with frequent sandstorms?
A:

For the specific requirements of coastal areas with frequent sandstorms, it is recommended to select products equipped with dustproof and sand-resistant features:

  • Rockwill Electric: DS7B-420D/3150, an outdoor high-voltage disconnector with an earthing switch, featuring a rated current of 3150A, high insulation withstand capability, strong corrosion resistance, and ease of maintenance, ensuring the safe and stable operation of high-voltage systems.

  • Pinggao Electric: GW27-550(W)/4000, marked with pollution resistance (W), suitable for harsh climatic conditions.

  • Shandong Taikai: GW5-252DD/3150-50, designed with a double-earthing configuration and optional accessories such as sand shields.

  • Changgao Electric: GW5C-252DD/3150, a customized improved version that allows for additional protective measures based on requirements.

Comparison Points:

  • Dustproof and Sand-Resistant Design: Pinggao's products explicitly indicate pollution resistance, while other manufacturers can achieve similar effects by configuring additional accessories.

  • Double-Earthing Configuration: Some models from Rockwill, Taikai, and Changgao support double-earthing, enhancing operational flexibility and safety.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Installation Requirements and Procedures for 10 kV High-Voltage Disconnect Switches
    First, the installation of 10 kV high-voltage disconnect switches must meet the following requirements. The first step is to select an appropriate installation location, typically near the switchgear power supply in the power system to facilitate operation and maintenance. At the same time, sufficient space must be ensured at the installation site to accommodate equipment placement and wiring.Secondly, equipment safety must be fully considered—for example, lightning protection and explosion-proo
    11/20/2025
  • Common Issues and Handling Measures for 145kV Disconnector Control Circuits
    The 145 kV disconnector is a critical switching device in substation electrical systems. It is used in conjunction with high-voltage circuit breakers and plays an important role in power grid operation:First, it isolates the power source, separating equipment under maintenance from the power system to ensure personnel and equipment safety;Second, it enables switching operations to change the system operating mode;Third, it is used to interrupt small-current circuits and bypass (loop) currents.Re
    11/20/2025
  • What are the six operating principles of disconnect switches?
    1. Operating Principle of the DisconnectorThe operating mechanism of the disconnector is connected to the active pole of the disconnector via a connecting tube. When the main shaft of the mechanism rotates 90°, it drives the insulating pillar of the active pole to rotate 90°. The bevel gears inside the base drive the insulating pillar on the other side to rotate in the opposite direction, thereby achieving opening and closing operations. The active pole, through inter-pole linkage tubes, drives
    11/19/2025
  • 36kV Disconnect Switch Selection Guide & Key Parameters
    Selection Guidelines for 36 kV Disconnect SwitchesWhen selecting the rated voltage, ensure that the disconnect switch’s rated voltage is equal to or higher than the nominal voltage of the power system at the installation point. For example, in a typical 36 kV power network, the disconnect switch must have a rated voltage of at least 36 kV.For rated current, selection should be based on the actual long-term load current. Generally, the switch’s rated current must be no less than the maximum conti
    11/19/2025
  • Copper Conductor Size vs Temperature Rise in 145kV Disconnectors
    The relationship between the temperature-rise current of a 145 kV disconnector and copper conductor size lies in balancing current-carrying capacity and heat dissipation efficiency. The temperature-rise current refers to the maximum continuous current a conductor can carry without exceeding its specified temperature rise limit, and the copper conductor size directly influences this parameter.Understanding this relationship begins with the physical properties of the conductor material. Copper’s c
    11/19/2025
  • Design of an Intelligent Control System for Fully Enclosed Disconnectors in Distribution Lines
    Intelligentization has become an important development direction for power systems. As a critical component of the power system, the stability and safety of 10 kV distribution network lines are vital to the overall operation of the power grid. The fully enclosed disconnector, as one of the key devices in distribution networks, plays a significant role; thus, achieving its intelligent control and optimized design is of great importance for enhancing the performance of distribution lines.This pape
    11/17/2025

Related Solutions

  • Intelligent High Voltage Outdoor Disconnector Solution for Vietnam's Distributed PV and Storage Projects
    1. Project BackgroundDistributed photovoltaic (PV) and energy storage projects are developing rapidly in Vietnam and Southeast Asia, but face severe challenges:1.1 Grid Vulnerability: Vietnam's grid experiences frequent fluctuations (especially in northern industrial zones). In 2023, coal power shortages caused large-scale blackouts, resulting in daily losses exceeding USD 5 million. Traditional PV systems lack rapid isolation capability, making them prone to equipment damage and safety incident
    06/03/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.