Circuit breaker spring mechanism ZN13

  • Circuit breaker spring mechanism ZN13

Key attributes

Brand Switchgear parts
Model NO. Circuit breaker spring mechanism ZN13
Rated voltage 40.5kV
Series ZN13

Product descriptions from the supplier

Description

The circuit breaker spring mechanism ZN13 is a core power component designed specifically for the ZN13 series medium voltage vacuum circuit breakers. It uses spring energy storage as the driving source and is widely used in 10kV-40.5kV medium voltage distribution systems, industrial substations, and urban distribution networks due to its "precise action, high reliability, and strong adaptability". It provides stable power for circuit breaker opening and closing operations and ensures the safe operation of the medium voltage power grid. ​
1、 Core working principle: Efficient logic driven by spring energy storage
1. Energy storage system design
In response to the operational power requirements of the ZN13 series circuit breaker (closing operation power ≥ 120J), the mechanism adopts a single set of main spring energy storage structure, and the core parameters and operating logic are as follows:
Spring selection: The main spring is made of 60Si2MnA alloy spring steel with a diameter of 18mm. After quenching at 950 ℃ and tempering at 420 ℃, the tensile strength reaches 1800MPa. When the maximum deformation is 28mm, it can store 150J of energy and meet the power requirements for circuit breaker closing; ​
Energy storage method: Supports "electric+manual" dual-mode. The electric energy storage is equipped with a 0.75kW single-phase motor (AC220V/380V optional), which drives the energy storage shaft to rotate through a two-stage gear reduction (reduction ratio 1:80). The cam compresses the spring, and the energy storage is locked by the pawl after completion, taking ≤ 12 seconds. The manual energy storage can be completed by shaking the handle (speed 25r/min) for ≤ 35 turns, suitable for emergency scenarios. ​
2. Collaborative opening and closing actions
The transmission connection between the mechanism and the ZN13 circuit breaker has been precisely calibrated to ensure synchronization and accuracy of the action
Closing process: After receiving the closing signal, the DC220V closing electromagnet (suction force ≥ 60N) pushes the release component, releases the pawl, and releases the main spring energy. The main shaft of the circuit breaker is driven to rotate through the steel transmission link (φ 12mm), and the moving contact is closed. The closing time is ≤ 70ms, ensuring fast power supply to the circuit; Simultaneously, the opening spring synchronously stretches and stores energy to prepare for opening; ​
Opening process: When a short circuit (short circuit current ≤ 31.5kA) or overload is detected, the opening electromagnet (or manual handle) will operate, the opening lock will release, the opening spring will release energy, and the moving contact will be driven to open. The opening time is ≤ 25ms, and the vacuum arc extinguishing chamber will be used to quickly cut off the arc. The opening rebound amount is ≤ 2mm, which meets the GB/T 1984 standard.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.