DNH1-160/21GR 2P fused switch

  • DNH1-160/21GR 2P fused switch
  • DNH1-160/21GR 2P fused switch
  • DNH1-160/21GR 2P fused switch
  • DNH1-160/21GR 2P fused switch

Key attributes

Brand Switchgear parts
Model NO. DNH1-160/21GR 2P fused switch
Rated voltage AC 400V
Rated normal current 250A
Rated frequency 50/60Hz
Series DNH1

Product descriptions from the supplier

Description

DNH1 series fuse-switch-disconnector (chere inafter refered to switch) is designed for the distribution circuit and electromot of circuit with high short circuit current, with rated AC voltage 400v and 690V, conventional thermal current up to 630A. It is used as power switch, switch disconnector and emergent switch, and with the function of circuit protection, but not used as a direct open or close single electromotor popularly. The low-voltage cabinets that are compatible are mostly concentrated in industrial and civilian power distribution scenarios, as follows: GGJ single-phase/small compensation cabinets, small power distribution cabinets, comprehensive distribution boxes (JP cabinets), civilian/small industrial JP cabinets,

This product is in conformity with standard GB14048.3(idt IEC60947-3).

fused switch

Product Selection

Main technical parameters

technical parameter

specifications DNH1-250 DNH1-160
  Rated working voltage Ue V AC400 AC690 AC400 AC690
  Rated working current Ie A 250 200 160 100
  Agreed heating current Ith A 250 200 160 100
  Rated limited short-circuit current (with fused core)   KA 100 50 100 50
  Usage category (with fused core)     AC-23B AC-23B AC-23B AC-23B
  Rated insulation voltage Ui V AC1000 AC1000 AC1000 AC1000
  Rated impulse withstand voltage Uimp KV 12 12 12 12
  Rated frequency   Hz 50/60 50/60 50/60 50/60
  Electrical life (number of cycles)   times 200 200 200 200
  Maximum torque   N.m 30 30 20 20
   

 

Fusible core

Executive standards:IEC60269-2/GB/T 13539.2     1 1 00 00
    Rated working current In A 200 200 160 100
    power dissipation Pn W 23 32 12 12
Normal use, installation, and transportation conditions Ambient air temperature -5℃~+40℃
  Altitude ≤2000m
  Installation category and pollution level Ⅲ、Ⅳ 3
  Transportation and Storage -25℃~+55℃

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.