DNH9 Fuse Switch Disconnector

  • DNH9 Fuse Switch Disconnector
  • DNH9 Fuse Switch Disconnector
  • DNH9 Fuse Switch Disconnector
  • DNH9 Fuse Switch Disconnector

Key attributes

Brand Switchgear parts
Model NO. DNH9 Fuse Switch Disconnector
Rated normal current 250A
Rated frequency 50/60Hz
Series DNH9

Product descriptions from the supplier

Description

Mainly used in distribution circuits and motor circuits with high short-circuit currents, as power switches, isolation switches, and application switches Emergency switch and used for AC circuit protection. Suitable for high short-circuit current scenarios, it can be used as a power switch, isolation switch, and emergency switch. It is also suitable for low-voltage cabinets in various scenarios such as industrial distribution and motor control. Specifically, it includes GGD low-voltage fixed distribution cabinet, GGJ low-voltage reactive power compensation cabinet, outdoor comprehensive distribution box (JP cabinet), emergency distribution cabinet, and small low-voltage cable branch box This switch is not suitable for directly opening and closing a single motor;Complies with national standard GB/T 14048.3 and international standard IEC/EN60947-3.

Working conditions
1.The ambient temperature range is -25 ℃~+55 ℃, and the average 24-hour value does not exceed+35 ℃. If the ambient temperature is lower than-25 ℃ or higher than+55 ℃, capacity reduction should be considered for use;
2. Altitude: The installation site has an altitude not exceeding 2000m;
3. When the maximum temperature is+40 ℃, the relative humidity of the air does not exceed 50%. Higher relative humidity can be allowed at lower temperatures, such as up to 90% at+20 ℃. Special measures should be taken for occasional condensation caused by temperature changes;
4. Pollution level: Level 3;
5. Installation category: III, IV;
6. It should be installed in a place without significant shaking, impact vibration, and invasion of rain and snow. At the same time, the installation location should be free of explosive hazardous media, and there should be no gas or dust in the media that is sufficient to corrode metals and damage insulation;
7. The switch should not bear additional mechanical stress, and external cables and busbars should be fixed through insulators, etc. Note: For special usage environments, please consult with the manufacturer.

Parameters 

Specifications Unit DNH9-160   DNH9-250  
Rated working voltage Ue V 230V AC 415V AC 1000V DC 690V AC
Rated working current Ie A 160 160 250 250
Agreed heating current Ith V 160 160 250 250
Rated limited short-circuit current (with fused core) kA 100 100 30 100
Usage category (with fused core)   AC-23B AC-23B DC-21B AC-23B
Rated insulation voltage Ui V 1000 1000 1000 1000
Rated impulse withstand voltage Uimp kV 12 12 12 12
Rated frequency Hz 50/60 50/60 50/60 50/60
Electrical lifespan (number of cycles of operation) times 200 200 200 200
Maximum torque N.m 30 30 30 30
Executive standard: IEC60269-2/GB/T 13539.2   1 1 1 1
Rated working current In A 160 160 250 200
Power consumption Pn W 23 23 ≤ 32 ≤ 32
Surrounding air temperature   -5°C ~ + 40°C -5°C ~ + 40°C -5°C ~ + 40°C -5°C ~ + 40°C
Altitude   ≤ 2000m ≤ 2000m ≤ 2000m ≤ 2000m
Installation category and pollution level   III、IV III、IV III、IV III、IV
Transportation and storage   -25°C ~ + 55°C -25°C ~ + 55°C -25°C ~ + 55°C -25°C ~ + 55°C

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.