DS1 12kV 40.5kV 72.5kV 225kV High voltage disconnect switch Direct Supply from China

  • DS1 12kV 40.5kV 72.5kV 225kV High voltage disconnect switch Direct Supply from China

Key attributes

Brand ROCKWILL
Model NO. DS1 12kV 40.5kV 72.5kV 225kV High voltage disconnect switch Direct Supply from China
Rated voltage 72.5kV
Rated normal current 2000A
Rated frequency 50/60Hz
Rated peak value withstand current 80kA
Rated short-time withstand current 31.5kA
Series DS1

Product descriptions from the supplier

Description

Product introduction:

DS1-12、40.5、72.5 switch disconnectors  are kinds of outdoor HV electricity transmission equipment’s at three-phase AC frequency of 50Hz/60Hz. It is used for breaking or connecting HV lines under no loads so that the power lines can be changed and connected and the way the electricity runs is changed. In addition, it can be used to exercise safe electrical insulation for such HV electric apparatuses as bus and break.

GW1  switch disconnector have two insulators with vertical open jewels. Vertical breaks Will be formed after closing, phase spacing can be educed. Its structure is simple, and it is a Widely used structure in early switch disconnector 

Product is made of conductive am, post insulator, operating insulator, and base. Conductive arm is derived by operation and connecting rod about 50 •tums up and down, complete the opening and closing operation. According the need, we can match manual or electric mechanism.

Main characteristic:

  • The conductive arm, made of Cu-alloy of high conductance rate is characteristic of high mechanical strength, large radiation area.

  • Self-energy contact finger-Pressure and stable, self-energy contact finger is characterized by high elasticity, high conductivity, high temperature resistant, corrosion resistant properties. The end of the contact finger is fixed, it can avoid increasing contact resistance. Tile contact finger has been acknowledged by the China National Utility Model Patent. The structure has been us的 more than ten years, more than 100000 sets, without overheating feedback.

  • Tile dynamic contact part adopts the self-cleaning structure. Tile products cleaning the contact surface during close and open operation itself, which reduce the contact resistance and avoid healing of contact surface.

  • The rotating parts of Switch disconnector are designed to be free maintenance. Imported self-lubricating shaft sleeve, high quality stainless steel shaft pin, long-lasting aviation grease are used for forever flexile rotation and no clamping stagnation

  • All Switch disconnectors are delivered after complete assembly and adjustment. The product is convention to install, significantly reducing installation work on site.

  • Provide one-key sequential control "double confirmation" function expansion

Main technical parameters:

Among these voltage levels 225kV/230kV/330kV/345kV Disconnect Switch, the rated short-circuit breaking current is 63kA, and customization is available.

NO

Specifications

Unit

Value

1

Rated voltage

kV

12

40.5

72.5

2

1min power frequency withstand voltage (r.m.s)

Phase to phase to earth

kV

55

95

107

Across isolating distance

kV

48

118

133

3

Lightning impulse withstand voltage (peak 1.2/50μs)

Phase to phase to earth

Across isolating distance

kV

96

185

209

kV

85

215

243

4

Rated frequency

Hz

50/60

5

Rated current

A

630/1250/2000/2500

6

Rated short - time withstand current (r.m.s)

kA

31.5/40

7

Rated peak withstand current

kA

80/100

8

Rated short - circuit withstand time

s

4

9

Wiring terminal static mechanical load

Longitudinal

N

500

1000

1000

Horizontal

N

252

750

750

Vertical

N

300

750

750

10

Mechanical life

Times

10K

11

Motor operating mechanism

Model

CJ12

12

Motor voltage

V

AC380/DC220/DC110

13

Control circuit's voltage

V

AC380/AC220/DC220/DC110

14

Opening/closing time

S

7±1

15

Manual operating mechanism

Model

CS14G

Order notice :

Product model, rated voltage, rated current, creepage distance must be specified at the goods-ordering time;

The disconnect switch offers several options of grounding;

The operating mechanism, motor voltage, control voltage and the number of contacts for auxiliary switch;

Installation method.

 

 

Documentation Resource Library
Restricted
12kV 40.5kV 72.5kV 225kV Vertical Break Disconnect Switch Installation Manual
Installation Manual
English
Consulting
Consulting
FAQ
Q: Which manufacturer's products should be prioritized for frequently operated wind farm step-up substations?
A:

Considering the requirements for equipment reliability and frequent operation in wind farm step-up substations, the following models are recommended:

  • Rockwill Electric: DS4C-252/4000, with voltage and current parameters highly compatible for outdoor applications in wind power scenarios, providing isolation functions to ensure operational safety.

  • Siyuan Electric: GW5-G-252D/2000, an improved design that enhances contact wear resistance and overall reliability.

  • Changgao Electric: GW5C-252DD/3150, specifically designed for renewable energy projects, featuring rapid response and high reliability.

  • Shandong Taikai: GW5-126D/2000, while with a lower voltage rating, is a suitable option for wind farm step-up substations at 126kV and below.

Comparison Points:

  • Operational Lifespan: The "G" improved version from Siyuan and the "C" optimized version from Changgao emphasize product durability, making them suitable for frequent operation scenarios.

  • Cost-Effectiveness: Products from Rockwill and Taikai are renowned for their cost-performance advantages, making them ideal choices when budget constraints are a concern.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.