H59 H61 20kV 30kV 33kV High Voltage Oil Immersed Toroidal Power Transformer

  • H59 H61 20kV 30kV 33kV High Voltage Oil Immersed Toroidal Power Transformer
  • H59 H61 20kV 30kV 33kV High Voltage Oil Immersed Toroidal Power Transformer
  • H59 H61 20kV 30kV 33kV High Voltage Oil Immersed Toroidal Power Transformer
  • H59 H61 20kV 30kV 33kV High Voltage Oil Immersed Toroidal Power Transformer

Key attributes

Brand Vziman
Model NO. H59 H61 20kV 30kV 33kV High Voltage Oil Immersed Toroidal Power Transformer
Rated voltage 33kV
Rated frequency 50/60Hz
Rated capacity 400kVA
Series S

Product descriptions from the supplier

Description

Product Description

The H59/H61 33/0.41kV pole-mounted high-voltage oil-immersed toroidal transformer is a premium three-phase power distribution solution tailored for industrial and civil grid applications. With 10 years of specialized transformer manufacturing experience, we deliver reliable performance that meets global industry standards.

Boasting a precise 33kV high-voltage input and 0.41kV low-voltage output, the toroidal design ensures low energy loss, high efficiency, and stable power transmission. Crafted with H59/H61 high-quality materials, it features excellent corrosion resistance and mechanical strength, paired with advanced oil-immersed insulation for long-term durability in outdoor environments.

Backed by authoritative Type Test Reports, the product guarantees compliance and safety. We also offer flexible OEM services to meet customized project requirements. Ideal for pole-mounted installations in distribution networks, industrial parks, and commercial complexes, this transformer combines professional manufacturing expertise, certified quality, and tailored solutions—your trusted choice for efficient, reliable power distribution.

Product Specification:
Frequency: 50Hz or 60Hz
Capacity: 5kVA ~500kVA
Primary Voltage: 2400~46, 000V
Secondary Voltage: 120~ 600V
Main Technical Datas:
Some of these earthing transformers cover voltage levels including:3.3 kV 5.5 kV  6 kV 6.6 kV 7.2 kV 10kV 10.5kV 11kV 13.2 kV 13.8 kV 15kV 17.5 kV 20 kV  22kV 24kV  30 kV 33kV 34.5kV 35 kV 46 kVetc. and customization is available.

Model NO.

S-m

Core

Core-type Transformer

Cooling Method

Oil-immersed Type Transformer

Winding Type

Two-winding Transformer

Certification

ISO9001-2000, ISO9001, CCC

Usage

Power Transformer

Frequency Characteristics

Power Frequency

Shape of Core

Ring

Brand

Vziman

Color

Gray, Green or Customized

Transport Package

Wooden Packing

Specification

IEC/ANSI/IEEE

Trademark

Vziman

Origin

China

HS Code

8504330000

Production Capacity

20000

 Product Scope:

  • Meet or exceeds ANSI Standards

  • Robust construction having excellent short circuit and thermal withstand capabilities

  • ROCKWELL Transformers are more efficient by Reduced no-load losses and Reduced load losses

  • Customized to Specific Requirements

Three phase pole mounted type distribution transformer Features:

  • Three phase transformer with more economical cost

  • Pole Mounted type transformer for easy installation

  • Oil Filled type for Cooling Method

  • Three phase pole mounted transformer is used for power transmission and distribution, with low loss and high efficiency

  • This type Three phase pole mounted transformer is advanced design to increase short-circuit strength, thermal strength

  • Durable and corrosion resistant finish meets all ANSI/IEC/BS Standards for single phase pole mounted transformer.

  • ROCKWELL Three Phase Pole mout type Automated Deisgn System insures each customer's unique requirements are satisfied.

  • C. R. G. O Silicon Steel or Amorphous Metal is available for customer's option.

Type D16 Series OA Three-Phase Pole-mounted Transformer(CRGO Core BIL 150)

product Photo

Pole Mounted High Voltage Oil Immersed Toroidal Power Transformer

11kV 33kV 35kV 44kV Pole Mounted High Voltage Oil Immersed Toroidal Power Transformer

Pole Mounted High Voltage Oil Immersed Toroidal Power Transformer

 

Durable H61 H59 33kv Power Distribution Transformer for Sale

Wenzhou Rockwell Transformer Co., Ltd. which is specialized in producing, developing and marketing power transmission and distribution products. The company is established in 2008, the subsidiary of ROCKWILL GROUP, which is located in Wenzhou city, Zhejiang province, China.

Our main products are including switchgear, ring main unit, transformer, load break switch, SF6/vacuum circuit breaker, substation, auto-recloser, voltage regulator, automatic sectionalizer, tap-changer, CT and PT etc.

Many of these products have the certification reports of the international authoritative KEMA Netherlands and CESI Italy.

We have a professional technical team which can provide you with full design solution and technical support.

Work shop

H59 H61 Oil Immersed Power Distribution Transformer

Certificates

H59 H61 Oil Immersed Power Distribution Transformer

 

Team

 

H59 H61 Oil Immersed Power Distribution Transformer

Project

H59 H61 13.2kV 13.8kV 15kV 33kV Oil Immersed Power Distribution Transformer Manufacturer

 

Shipping

H59 H61 13.2kV 13.8kV 15kV 33kV Oil Immersed Power Distribution Transformer Manufacturer

Attention

  1. The payment term: We accept TT,30% deposit and 70% balance against copy of BL.

  2. The delivery time: Usually it will take about 15-20 days.

  3. The standard of package: Usually use strong plywood case for protection.

  4. The logo: If you have good quantity, it absolute no problem to do OEM.

  5. Our market: our products are popular in Indonesia, Philippines, Russia, USA, Middle East and so on. Some of them are our regular customers and some of them are developing. We hope you can join us and make mutual benefit from our cooperation..

  6. Warranty: in 12 month since BL date.

Our Service

  1. quick response in before sales period help you got order.

  2. excell ent service in production time let you know each step we made.

  3. reliable quality solve you after sale headache.

  4. long period quality warranty ensure you can buy without hesitate.

Why Choose Vziman

  • One-stop supplier globally.

  • More than 10 years professional experiences in electrical appliance industry.

  • We offer professional online technology support for perfecting your electrical solution free.

  • Experienced sales service and suggestion.

  • All the products with accessories under strict quality control and final inspection before ship

  • We can assure the powerful competitive price and reliable quality products.

  • Most competitive shipping rate from our own shipping forwarder.

  • Warranty assurance: 12 month

  • Whatever big or small order, we can provide you one-to-one service.

Documentation Resource Library
Restricted
Vziman IEC/ ANSI Oil-immersed Power transformer selection catalog
Catalogue
English
Consulting
Consulting
FAQ
Q: What are the specific models of H59 series transformers with different capacities under the 20kV voltage class?
A:

 50KVA capacity (copper winding), suitable for 20kV power grid: H59 50kVA 20KV 400V ±5%
100KVA capacity (copper winding): H59 100KVA 20KV 400V ±5%
160KVA capacity (copper winding): H59 160KVA 20KV 400V ±5%
250KVA capacity:
Aluminum winding version: H59 250KVA 20KV 400V ±5% ALU
Copper winding version: H59 250kVA 20KV 400V ±5%
630kVA capacity:
Aluminum winding under 20kV voltage class: H59 630kVA 20KV 400V ±5% ALU
Copper winding under 20kV voltage class: H59 630kVA 20kV 400V ±5% CU

Q: What are the key maintenance points for the oil-immersed toroidal transformer?
A:
  1. Regularly check the insulation oil level and quality: Ensure the oil level is within the standard range (1/2-2/3 of the oil tank) and replace aged or contaminated oil annually to maintain insulation performance.
  2. Inspect the toroidal core and windings: Conduct a visual check every 6 months for signs of corrosion, loose connections, or overheating (e.g., discoloration), and clean dust with dry air to avoid insulation degradation.
  3. Monitor protective devices: Verify the functionality of pressure relief valves and temperature monitors quarterly to ensure timely alarms for overpressure/overtemperature.
  4. Environmental protection: Keep the transformer installed in a well-ventilated area free from debris accumulation, and protect the H59/H61 metal case from direct impact to extend its service life.
Q: Which application scenarios is this 33/0.41kV toroidal power transformer suitable for?
A:

This H59/H61 33/0.41kV high-voltage oil-immersed toroidal transformer is ideally suited for pole-mounted installation in medium-voltage distribution networks, industrial parks, rural power grids, and commercial complexes. Its toroidal structure ensures compact size and low energy loss, making it perfect for scenarios requiring space-saving installation and stable power supply—such as power distribution for production lines, residential area centralized power supply, and remote area grid extension. It operates reliably in harsh outdoor environments with temperature ranges from -30℃ to 50℃, adapting to humidity, dust, and other adverse conditions.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 10000m² Total staff: 300 Highest Annual Export(usD): 150000000
Workplace: 10000m²
Total staff: 300
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Choosing Vizman Distribution Transformers: Innovative Customization to Meet Diverse Power Needs
    Distribution transformers are the heart of local electricity distribution systems. They step down voltage, enabling safe and efficient power supply to homes and businesses.At Vizman Electric Power Technology Co., Ltd., we understand the critical role of distribution transformers in the energy ecosystem. That's why we specialize in manufacturing high-quality distribution transformers, providing tailored solutions to meet diverse energy needs.1.Solutions Offered by Vizman Electric Power Technology
    04/16/2025
  • SF6 Circuit Breaker Solutions in High-Voltage Power Systems: A Case Study of VZIMAN Company
    1. Challenges in High-Voltage Power Systems1.1 High-voltage power systems, as the core of power transmission, face critical challenges: Equipment Performance Limits: With increasing voltage levels (e.g., 500kV and above), traditional circuit breakers struggle to meet high breaking capacities (over 40kA) and rapid insulation recovery requirements. Overvoltage Risks: Switching capacitive loads (e.g., capacitor banks) may cause reignition, leading to dangerous overvoltages. Poor Environmental Adapt
    05/13/2025
  • VZIMAN Company SF6 Circuit Breaker Solutions for Renewable Energy Grid Integration
    1. Current Challenges in Renewable Energy Grid Integration1.1 Grid Frequency Fluctuations and Stability IssuesThe intermittency and variability of renewable energy sources (e.g., wind and solar) lead to frequent grid frequency changes. Traditional circuit breakers struggle to respond rapidly to such dynamic loads, potentially causing equipment damage or regional blackouts. For instance, during sudden drops in wind power or abrupt solar output fluctuations, the grid must isolate faults within mil
    05/13/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.