High Voltage Current-Limiting Fuse(For use in oil switchgear)

  • High Voltage Current-Limiting Fuse(For use in oil switchgear)
  • High Voltage Current-Limiting Fuse(For use in oil switchgear)

Key attributes

Brand Wone
Model NO. High Voltage Current-Limiting Fuse(For use in oil switchgear)
Rated voltage 3.6kV
Rated normal current 100A
Breaking capacity 50kA
Series Current-Limiting Fuse

Product descriptions from the supplier

Description

Characteristic brief:

  • Rated voltage from 3.6KV to 12KV.

  • Wide range of rated current from 6.3A to 250A.

  • Powerful pyrotechnic striker.

  • Unique tripe seal.

  • H.R.C.

  • Current-limiting.

  • Low power dissipation, low temperature rise.

  • Operation extremely quickly, high reliability.

  • Mainly used for back-up protection in transformers of American type.

  • Conforming to standards: GB15166.2 BS2692-1 / IEC60282-1.

Model illustration:

企业微信截图_17337315196798.png

Technical Parameters:

企业微信截图_17337916132142.png

 External dimensions:

企业微信截图_17337326096660.png

BS&DINtype H.V. fuse link cross section compared:(Unit:mm)

企业微信截图_17337316849417.png

企业微信截图_17337317137278.png

BS Type H.V Fuse Link Cross Section

What is the working principle of high-voltage current-limiting fuses (for oil switchgear)?

Normal Operating State:

  • During normal operation, the high-voltage current-limiting fuse has a very low resistance, allowing the normal operating current to pass through without affecting the circuit. Essentially, it behaves like a regular conductor, permitting current to flow smoothly.

Fault Current Limitation:

  • When an overload or short-circuit fault occurs in the circuit, causing the current to exceed the fuse's rated current, the fusible element begins to heat up. Due to the large magnitude of overcurrent or short-circuit current, the heating rate of the fusible element is rapid, and it reaches its melting point within a short time, leading to its immediate melting.

  • At the moment the fusible element melts, an arc is generated. At this point, the arc-quenching device activates. As previously mentioned, materials such as oil and possibly quartz sand are used to extinguish the arc during this process. Simultaneously, due to the current-limiting effect of the fuse, the amplitude of the fault current is restricted within a certain range, preventing it from increasing uncontrollably.


Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 65666m²m² Total staff: 300+ Highest Annual Export(usD): 50000000
Workplace: 65666m²m²
Total staff: 300+
Highest Annual Export(usD): 50000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.