10kV High-voltage series reactors for Serial Connection

  • 10kV High-voltage series reactors for Serial Connection

Key attributes

Brand POWERTECH
Model NO. High-voltage series reactors
Rated voltage 10kV
Capacity 3KVar
Series CKSC

Product descriptions from the supplier

Description

 Function:

The series reactor is connected in series with the shunt capacitor group, which has the functions of compensating the reactive power of the power grid, improving the power factor, suppressing the harmonic current, limiting the closing inrush current, etc., and is suitable for the power system, electrified railway, metallurgy, petrochemical and other high fire protection requirements. Places such as urban grid substations, underground substations and microcomputer-controlled substations with limited electromagnetic interference requirements and installation space.

Parameters to be provided when ordering:

  •  The rated capacity of the reactor.

  • System rated voltage and frequency.

  •  Capacitor terminal voltage.

  •  Rated reactance or reactance rate of reactor.

  •  Rated current and continuous current.

  • Dynamic and thermal stability current and duration.

  • Other special requirements.

企业微信截图_17331878222488.png

Standard:

  • IEC289-88 "reactor".

  • GB10229-88 "Reactor".

  • JB5346-98 "Reactor".

  • DL462-92 "Technical Conditions for Ordering Series Reactors for High Voltage Shunt Capacitors".

Structural characteristics:

  •  The reactor is divided into three phase and single phase, both of which are epoxy casting.

  • The core is made of low-loss cold-rolled oriented silicon steel sheet, which is punched and sheared by a high-speed punch, which has small burrs, regular uniformity, and neat and beautiful lamination, so as to ensure the performance of low temperature rise and low noise during the operation of the reactor.

  •  The coil is epoxy casting, the coil is reinforced by laying epoxy glass mesh cloth inside and outside, and the F-class epoxy casting system is used to pour in a vacuum state, the coil not only has good insulation performance, but also has good mechanical strength, and can withstand large current impact and cold and hot shock without cracking.

  •  The epoxy casting coil does not absorb water, has low partial discharge, and can operate safely under harsh environmental conditions.

  • The upper and lower ends of the coil are made of epoxy cushion blocks and silicone rubber shockproof pads, which effectively reduce the vibration of the coil during operation.

Conditions for the use:

  • The altitude does not exceed 2000 meters.

  •  The operating environment temperature is -25°C~+40°C, and the relative humidity is not more than 93%.

  • There are no harmful gases around, no flammable and explosive materials.

  •  The surrounding environment should have good ventilation conditions.

  •  Insulation Grade: Class F, Reactor Noise: ≤45dB

  • Overload capacity: continuous operation at ≤ 1.35 times

  • The uneven transverse between the phases of the reactor is not more than ±3%, and the inductance error is controlled within +3%.

  •  Insulation level: LI75AC35kV

 

What is the principle of inductance characteristics of a reactor?

Inductive Characteristics Principle:

  • Reactors operate based on the principle of electromagnetic induction. When current flows through the windings, a magnetic field is generated in the core. According to Lenz's Law, this magnetic field opposes the change in current, thereby limiting the rate of change of the current.

  • For example, in an alternating current (AC) circuit, where the current is continuously changing, the inductance of the reactor causes the current to lag behind the voltage in phase. This phase shift results in the generation of reactive power, which can be used for reactive power compensation in the circuit.

  • In a direct current (DC) circuit, reactors can smooth out the current, reducing fluctuations and providing a more stable current flow.


Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 580000m² Total staff: Highest Annual Export(usD): 120000000
Workplace: 580000m²
Total staff:
Highest Annual Export(usD): 120000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Core Value and Innovative Applications of 12kV Medium Voltage Switchgear in Smart Substations​
    With the Rapid Development of Smart Grids and the Integration of Renewable Energy Medium Voltage (MV) Switchgear, as the core power distribution equipment in substations, directly determines the stability of the power system through its reliability, intelligence, and space efficiency. This article delves into the key technologies, scenario-specific solutions, and practical benefits of Medium Voltage Switchgear in substations.Core Requirements for Substation ScenariosHigh Reliability Requirements
    06/12/2025
  • Withdrawable 12kV Medium Voltage Switchgear: The Indispensable Pivot of Flexibility and Safety in Smart Grids
    At the core of medium-voltage power distribution systems in industrial facilities, commercial complexes, and data centers, switchgear acts as a silent commander, governing the lifeline of electrical flow. Among various solutions, ​Withdrawable Switchgear​has become synonymous with reliability in modern MV systems due to its unique design philosophy. Compared to fixed switchgear, its "withdrawable" feature delivers compelling advantages, setting new benchmarks for ​operational efficiency​and ​per
    06/12/2025
  • Core Dilemma in Southeast Asia 12kV Medium Voltage Switchgear​
    Southeast Asia’s rapidly growing power demand (GDP growth >5% annually) combined with extreme climatic conditions—high temperature, humidity, and salt spray corrosion—necessitates balancing lifecycle costs with climate resilience in switchgear selection. This article analyzes the optimal cost-performance solutions between GIS and AIS.​I. GIS vs. AIS Cost Comparison Model (Southeast Asia Context)​​​1. Initial Investment Costs​2. Long-Term Operational Costs​​GIS Advantages:Ext
    06/12/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.