Key attributes

Brand Switchgear parts
Model NO. IEC Type Tee connector
Rated voltage 24kV
Rated normal current 630A
Series RW-QCBT

Product descriptions from the supplier

Description

Summary
Shielding 630A IEC type Tee connector, directly connect to the bushing of switchgear and the wall bushing of cable branch box.provide fully insulated safety circuits for SF6 gas switchgear cabinet and cable branch boxes. The tail can be plugged directly with insulating plugs, but also extend the connection after the connection Head or rear connector with surge arrester. Through 630A prefabricated joints to achieve single-phase or three-phase insulated cables and transformers, switchgear, branch boxes and other equipment connected. The products is suitable for indoor and outdoor installation, continuous rated current is 630A (900A overload for 8 hours). When the product is fitted with a suitable bushing or plug, a fully shielded and hermetically separable connection is provided. Long-term underwater and others Harsh conditions of operation. For cross-section of the cable cross-section of 25mm² ~630mm² XLPE cable.

Standard packing
Body of Tee connector
Silicone grease、towels
Stress cone
Instruction Manual
Positioning chain, Phase ribbon
nInsulating plug (incude Semi-conductive end cap)
Handles, gauze
Dust cap
Terminals
Rulers for installation
Bolt stud
Conformity certificat

Technical specification

Item

Parameter

Rate voltage

12kV                         24kV                     35kV

Rate current

630A                         630A                     630A

Power frequency withstand voltage for 1 min

42Kv                         54kv                      117kv

Impulse voltage (10 times of positive and negative polarity)

95kV                         125kV                    200kV

Partial discharge

       15kV,≤10pC               21kV,≤10pC            45kV,≤10pC

Shielding resistance

≤5000Ω

Ordering information

   Product model

RW-QCBT 12kV-630A-25mm²       RW-QCBT 24kV-630A-25mm²       RW-QCBT 35kV-630A-25mm²

RW-QCBT 12kV-630A-35mm²       RW-QCBT 24kV-630A-35mm²       RW-QCBT 35kV-630A-35mm²

RW-QCBT 12kV-630A-50mm²       RW-QCBT 24kV-630A-50mm²       RW-QCBT 35kV-630A-50mm²

RW-QCBT 12kV-630A-70mm²       RW-QCBT 24kV-630A-70mm²       RW-QCBT 35kV-630A-70mm²

RW-QCBT 12kV-630A-120mm²      RW-QCBT 24kV-630A-120mm²      RW-QCBT 35kV-630A-120mm²

RW-QCBT 12kV-630A-150mm²      RW-QCBT 24kV-630A-150mm²      RW-QCBT 35kV-630A-150mm²

RW-QCBT 12kV-630A-185mm²      RW-QCBT 24kV-630A-185mm²      RW-QCBT 35kV-630A-185mm²

RW-QCBT 12kV-630A-240mm²      RW-QCBT 24kV-630A-240mm²      RW-QCBT 35kV-630A-240mm²

RW-QCBT 12kV-630A-300mm²       RW-QCBT 24kV-630A-300mm²      RW QCBT 35kV-630A-500mm²

RW-QCBT 12kV-630A-400mm²       RW-QCBT 24kV-630A-400mm²      RW-QCBT 35kV-630A-500mm²

RW-QCBT 12kV-630A-500mm²       RW-QCBT 24kV-630A-500mm²       RW-QCBT 35kV-630A-500mm²

                                                         RW-QCBT 24kV-630A-630mm²       RW-QCBT 35kV-630A-630mm²

 

Note: Selection should depend on the outside diameter of insulation of cable, the cable cross-section only for reference

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.