• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Low voltage pole mounted circuit breaker D165T with digital trip unit

  • Low voltage pole mounted circuit breaker D165T with digital trip unit

Key attributes

Brand Wone Store
Model NO. Low voltage pole mounted circuit breaker D165T with digital trip unit
Rated normal current 165A
Rated frequency 50/60Hz
Series D

Product descriptions from the supplier

Description

Description

These breakers are designed to operate within low - voltage networks, typically handling voltages of 600V AC or less and 750V DC or less. Their primary function is to interrupt the flow of current when faults such as overloads, short - circuits, or under - voltage conditions occur. They are widely used in various applications, including industrial plants, commercial buildings, and residential electrical systems. In industrial settings, they protect large - scale machinery and equipment from electrical malfunctions. In commercial buildings, they ensure the safety of lighting, heating, and cooling systems. In residential areas, they safeguard household appliances and wiring.

Features

  • Safe Circuit Interruption:LV circuit breakers are engineered to open and close circuits safely. This is vital as improper circuit interruption can lead to electrical arcs, which may cause fires or damage to equipment. They can handle the high - energy surges associated with breaking an electrical circuit without endangering the surrounding environment.

  • Repeated Breaking Operations:They are capable of performing breaking operations repeatedly. This feature ensures long - term reliability. In a power system where faults may occur occasionally, the breaker needs to be able to respond multiple times without degradation in performance. For example, in an industrial facility with fluctuating electrical loads, the breaker may need to trip and reset several times over its lifespan.

  • Multiple Electrode Breaking:Many LV circuit breakers can break multiple electrodes simultaneously. In complex electrical setups, such as three - phase power systems, this ability allows for the quick and effective isolation of all live conductors during a fault. This helps in preventing the spread of electrical faults and reduces the risk of damage to connected equipment.

  • High Breaking Capacity:Some models possess high breaking capacities. This is especially important in industrial and commercial applications where large short - circuit currents can occur. For instance, in a manufacturing plant with high - power machinery, a short - circuit could generate a substantial amount of current. A breaker with a high breaking capacity can safely interrupt this large current, protecting the entire electrical infrastructure.

Main Parameters

Dimensions

Weight

17 kg

Height

550 mm

Width

370 mm

Length

400 mm

Standards

Standards

HN 63-S-11

Electrical values

Rated Voltage (Ur)

0.44 kV

Rated current

165 A

Rated short-circuit breaking capacity

4 kA

Rated short-circuit making current

6.8 kA

Rated short-time withstand current (1s)

4 kA/s


10 kV

Lightning impulse withstand level of voltage (1.2/50)

20 kV

Features

Degree of protection

IP31

Output number

1

Conductor size

25 - 70mm²

Temperatures

Operating temperature

-25 ... 50 °C

Storage temperature

-25 ... 70 °C

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Dedicated Vacuum Contactor Solution for Port Shore Power Systems
    I. Background and Challenges​Shore power systems have become core technical equipment for ports to reduce carbon emissions and noise pollution. However, these systems face two major challenges in the harsh operational environment of ports:​Severe Environmental Corrosion: High humidity and salt spray in port areas cause serious corrosion to metal components and enclosures of electrical equipment, significantly impacting electrical lifespan and operational reliability.​High Switching Requirements:
    09/13/2025
  • ABB Vacuum Contactor KC2 Power Supply System Technical Transformation Plan
    Issue Overview​The 10kV air compressor starting system of a company utilizes the ABB vacuum contactor KC2 as the control component for the operating circuit. The dedicated wide-voltage power supply module paired with this contactor presents the following issues:​Frequent failures: The power supply module fails to properly transition the voltage from 300V to 12V, resulting in fuse blowouts.​Poor heat dissipation: Enclosed installation of the module leads to insufficient heat dissipation, acceler
    09/13/2025
  • Solution for Medium-Voltage Motor Control and Protection Using Vacuum Contactor-Fuse (VCF) in a Coal Conveying System
    1.Project BackgroundA coal conveying system comprises 15 belt conveyors driven by medium-voltage motors. The system operates under complex conditions, with motors often subjected to heavy loads and frequent starts. To address these challenges and achieve effective control and reliable protection during motor startup, the project comprehensively adopts Vacuum Contactor-Fuse (VCF) combination devices for the 6kV medium-voltage motor power distribution. This solution details the technical features,
    09/13/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.