Minera MP Oil Immersed Medium Power Transformers

  • Minera MP Oil Immersed Medium Power Transformers

Key attributes

Brand Schneider
Model NO. Minera MP Oil Immersed Medium Power Transformers
Rated frequency 50/60Hz
Series Minera MP

Product descriptions from the supplier

Description

General

Our broad range for Minera MP transformers includes:

  • Three phase units (single phase available on request)

  • Ratings up to 80 MVA, 50 or 60 Hz

  • Voltage insulation level up to 170 kV

  • Breathing or sealed type

  • A wide range of accessories

  • High capacity cooling options such as ONAN, ONAF, OFAF, OFWF or others upon request

  • Standard or low noise levels

  • Off-circuit tap changer (OCTC) or on load tap changer (OLTC)

Minera MP oil-immersed transformers are also available upon request for special applications including rectifier, hazardous area transformers, reactors (shunt and series), auto-transformers, step-up transformers, Solar power plant , Wind Mill Application etc.
Minera MP oil-immersed transformers meet the requirements of international standards such as ANSI, IEEE, IEC as well as other international/national standards.

 

Technical caracteristics 

 

The right tune for your network

Depending on your application and the different environmental influences you meet, we are able to deliver you a large variety of Minera MP transformers. Schneider Electric’s R&D team has created special designs for all your particular needs:

  • Breathing type and sealed type

  • For indoor application in buildings or industrial plants and in compact distribution substations

  • For outdoor applications

  • Normal noise level for urban or residential areas

  • Normal, low or very low level of losses

As customer satisfaction is our main concern, we constantly improve our manufacturing process, thus we are able to speed up delivery time while ensuring that all ISO 9001, ISO 14001 and/or ISO 18001 requirements are met at each production step. To ensure this high level of quality, our Minera MP transformers undergo routine tests in accordance with international standards such as IEC, ANSI standards. We can also provide type tests or special tests on request.

 

 

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 20000m² Total staff: Highest Annual Export(usD): 400000000
Workplace: 20000m²
Total staff:
Highest Annual Export(usD): 400000000
Services
Business Type: Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • EcoStruxure™ Connected solutions
    What is EcoStruxure™ ?EcoStruxure™ is our open, interoperable, IoT-enabled system architectureand platform. EcoStruxure delivers enhanced value around safety, reliability,efficiency, sustainability, and connectivity for our customers. EcoStruxureleverages advancements in IoT, mobility, sensing, cloud, analytics, andcybersecurity to deliver Innovation at Every Level. This includes ConnectedProducts, Edge Control, and Apps, Analytics & Services, which are supported byCustomer Lifec
    04/23/2025
  • RM6 SeT Digital solutions
    Digital solutionsDistributed DTU Easergy T300Comprehensive features and flexbile scalabilityTailored to meet future operational challenges ofdistribution network automationApplications range from monitoring rooms tomedium and low voltage distribution stationsTH110-R cable joint temperature measurementWireless passive, easy to installDirect measurement of conductor temperaturewith high accuracyPD110 series local discharge test deviceReal-time monitoring of equipment corona andpartial discharge st
    04/30/2025
  • Your trusted partner for wind turbine and wind farm solutions
    Solutions overviewControl of the wind turbineEnsure an optimized operating environmentGain greater control of the turbine through automation and backup powerChoosing the most efficient wind turbine is the key to success. Schneider Electric offers a fully automated wind turbine with the programmablelogic controller (PLC) and a highly-reliable UPS. They have a very low power consumption, and can be easily modified or upgraded.As such, the PLC functions as the “brain” of the wind turbin
    05/05/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now