• Minera MP Oil Immersed Medium Power Transformers
Minera MP Oil Immersed Medium Power Transformers
discuss personally
Model
Minera MP-50/60
Basic info
Brand Schneider
Model NO. Minera MP Oil Immersed Medium Power Transformers
Rated frequency 50/60Hz
Series Minera MP
Product Detail

General

Our broad range for Minera MP transformers includes:

  • Three phase units (single phase available on request)

  • Ratings up to 80 MVA, 50 or 60 Hz

  • Voltage insulation level up to 170 kV

  • Breathing or sealed type

  • A wide range of accessories

  • High capacity cooling options such as ONAN, ONAF, OFAF, OFWF or others upon request

  • Standard or low noise levels

  • Off-circuit tap changer (OCTC) or on load tap changer (OLTC)

Minera MP oil-immersed transformers are also available upon request for special applications including rectifier, hazardous area transformers, reactors (shunt and series), auto-transformers, step-up transformers, Solar power plant , Wind Mill Application etc.
Minera MP oil-immersed transformers meet the requirements of international standards such as ANSI, IEEE, IEC as well as other international/national standards.

 

Technical caracteristics 

 

The right tune for your network

Depending on your application and the different environmental influences you meet, we are able to deliver you a large variety of Minera MP transformers. Schneider Electric’s R&D team has created special designs for all your particular needs:

  • Breathing type and sealed type

  • For indoor application in buildings or industrial plants and in compact distribution substations

  • For outdoor applications

  • Normal noise level for urban or residential areas

  • Normal, low or very low level of losses

As customer satisfaction is our main concern, we constantly improve our manufacturing process, thus we are able to speed up delivery time while ensuring that all ISO 9001, ISO 14001 and/or ISO 18001 requirements are met at each production step. To ensure this high level of quality, our Minera MP transformers undergo routine tests in accordance with international standards such as IEC, ANSI standards. We can also provide type tests or special tests on request.

 

 

Know your supplier
Schneider
Chengdu Fabo Automation Complete Equipment Co., Ltd is an authorized distributor of Schneider Electric, a global leader in energy management and automation solutions.
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus
Business Type
Manufacture/Sales
Highest Annual Export (USD)
$400000000
Professional Experience
10 years
Workplace
20000m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!