Mini Vertical Fuse Switch Disconnector 60mm Busbar System

  • Mini Vertical Fuse Switch Disconnector 60mm Busbar System

Key attributes

Brand Switchgear parts
Model NO. Mini Vertical Fuse Switch Disconnector 60mm Busbar System
Rated voltage AC500V
Rated normal current 32A
number of poles 3P
Series Mini Vertical

Product descriptions from the supplier

Description

Product Features
1. Compact design
Specially designed for 60mm standard busbar system, vertically installed to save space, suitable for compact scenarios such as distribution cabinets
2. Function integration
Combining the functions of isolation switch and fuse, it supports manual disconnection and overload protection, and some models come with fuse slots
3. Rated parameters
Current range: commonly 125A~630A (matching busbar current carrying capacity)
Voltage level: 500V~1000V (low voltage system)
Breaking capacity: Compliant with IEC standards, some models have a breaking capacity of up to 50kA

Typical Applications
1. Industrial power distribution
Used for segmented protection of 60mm busbar systems, such as air insulated ring main unit (RMU) cabinet incoming and outgoing line isolation
2. New energy equipment
Suitable for DC side protection of photovoltaic inverters, energy storage systems, etc. (voltage withstand level needs to be confirmed)
3. Maintain safety
Provide visible breakpoints and ensure that the busbar is completely powered off during maintenance

Selection suggestions
Match busbar
Need to confirm the width of the bus duct (60mm) and the current carrying capacity (if the copper bar is vertically placed, the current carrying capacity is higher)
Operation method
Handle operation: suitable for frequent scene switching
Electric operation: remote control requirements (such as QSA series)

 Installation precautions
Vertical installation
Ensure even contact pressure and avoid poor contact caused by gravity
Heat dissipation requirements
60mm busbar system needs to reserve heat dissipation space to avoid high temperature and capacity reduction
Interlocking protection
It is recommended to use it in conjunction with a circuit breaker to prevent operation under load

Mini Vertical Fuse Switch Disconnector 1

Item No. DN56017
Rated operational current Ie 25A(690V)/32A(500V)
Rated operational voltage Ue 690VAC/500VAC
Rated insulation voltage Ui 800V
Rated impulse withstand current Ipk 6KV
Breaking capacity with fuse 100kA(500VAC)/50kA(690VAC)
System 60mm
Pole 3
Operation type Three - phase synchronous operation (3L)
Mounting method Hanging type
Suitable for busbar 12、15、20、25、30 x 5、10 and irregular copper busbar
Wiring range 1.5 - 6mm²
With(or without) LED indicator Without
Suit for fuse DO 10X38
Reference standard IEC 60269 - 1 IEC 60269 - 2
GB/T 13539.2

Mini Vertical Fuse Switch Disconnector 2

Item No. DN56018
Rated operational current Ie 25A(690V)/32A(500V)
Rated operational voltage Ue 690VAC/500VAC
Rated insulation voltage Ui 800V
Rated impulse withstand current Ipk 6KV
Breaking capacity with fuse 100kA(500VAC)/50kA(690VAC)
System 60mm
Pole 3
Operation type Three - phase synchronous operation (3L)
Mounting method Hanging type
Suitable for busbar 12、15、20、25、30 x 5、10 and irregular copper busbar
Wiring range 1.5 - 6mm²
With(or without) LED indicator With
Suit for fuse DO 10X38
Reference standard IEC 60269 - 1 IEC 60269 - 2
GB/T 13539.2

Mini Vertical Fuse Switch Disconnector 3

Item No. DN56019
Rated operational current Ie 25A(690V)/32A(500V)
Rated operational voltage Ue 690VAC/500VAC
Rated insulation voltage Ui 800V
Rated impulse withstand current Ipk 6KV
Breaking capacity with fuse 100kA(500VAC)/50kA(690VAC)
System 60mm
Pole 3
Operation type Three phase separate operation (3S)
Mounting method Hanging type
Suitable for busbar 12、15、20、25、30 x 5、10 and irregular copper busbar
Wiring range 1.5 - 6mm²
With(or without) LED indicator Without
Suit for fuse DO 10X38
Reference standard

IEC 60269 - 1 IEC 60269 - 2
GB/T 13539.2

Mini Vertical Fuse Switch Disconnector 4

Item No. DN56020
Rated operational current Ie 25A(690V)/32A(500V)
Rated operational voltage Ue 690VAC/500VAC
Rated insulation voltage Ui 800V
Rated impulse withstand current Ipk 6KV
Breaking capacity with fuse 100kA(500VAC)/50kA(690VAC)
System 60mm
Pole 3
Operation type Three phase separate operation (3S)
Mounting method Hanging type
Suitable for busbar 12、15、20、25、30 x 5、10 and irregular copper busbar
Wiring range 1.5 - 6mm²
With(or without) LED indicator With
Suit for fuse DO 10X38
Reference standard IEC 60269 - 1 IEC 60269 - 2
GB/T 13539.2
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.