• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


PG208 Protected Pressure Transmitter

  • PG208 Protected Pressure Transmitter
  • PG208 Protected Pressure Transmitter
  • PG208 Protected Pressure Transmitter
  • PG208 Protected Pressure Transmitter

Key attributes

Brand Wone
Model NO. PG208 Protected Pressure Transmitter
Power supply 9~30VDC
Type of pressure Gauge pressure
display Yes
Series PG208

Product descriptions from the supplier

Description

Description

The protective pressure transmitter adopts imported silicon wafers, with high precision and stable performance; As a sensing element, the silicon piezoresistive pressure core has a built-in processing circuit that converts the millivolt signal of the sensor into a standard voltage and current signal, and combines it with the unit instrument, DCS system, PLC, etc. to form an automatic control system, which is an ideal pressure measuring instrument in the field of industrial automation. It is an ideal pressure measuring instrument in the field of industrial automation to form an automatic control system.

Industry applications

It is widely used in various industrial fields (automation equipment and petroleum, chemical, natural gas, energy, etc.) where fluid pressure needs to be measured.

Features

Diaphragm isolation technology is adopted, which has high stability and high reliability.

Integrated chip, wide voltage power supply.

 Integral die-cast aluminum structure, strong and reliable.

 Frequency cut-off design, strong anti-interference ability, lightning protection.

Current limiting, voltage limiting, reverse polarity protection (current limiting output).

High precision, good stability, fast response speed and impact resistance.

Technical parameters

Measuring medium Liquids or gases (compatible with contact materials)
Pressure range - 100 k Pa~ 0 ~ 100 MPa
Pressure mode Gauge pressure, absolute pressure, negative pressure
Output signal 4 ~ 20 m A 0 ~ 10 VDC 0 ~ 5 VDC RS 485 customized
Supply voltage 9 ~ 30 VDC
Accuracy class ± 0.25 % FS ± 0.5 % FS Header display accuracy 0 . 5-level, digital tube (LED) display
working conditions Medium temperature - 40 ~ 80 °C Ambient temperature - 40 ~ 80 °C
Seismic performance 10 g( 20 ... 2000 Hz)
Overload capacity 1.5 times ~ 5 times
Frequency of response Analog signal output ≤ 500 Hz and digital signal output ≤ 5 Hz
Stable performance ± 0 . 1 % FS/year
Temperature drift ±0 . 01 % FS/ °C (within temperature compensation)
Ingress protection IP 65 IP 66
Explosion-proof type Flameproof ExdII.CT 6 Gb Intrinsically Safe ExiaII.CT 6 Ga
Load characteristics Current load ≤{(Us- 7.5 )÷ 0.02 ( Us=supply voltage)}Ω Voltage load≥ 100 k Ω

Product show

企业微信截图_17157381573209.png

企业微信截图_17157381856397.png

     企业微信截图_17157382114987.png

企业微信截图_17157382354458.png




Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 65666m²m² Total staff: 300+ Highest Annual Export(usD): 50000000
Workplace: 65666m²m²
Total staff: 300+
Highest Annual Export(usD): 50000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.