• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


RWB-7000L Line Protection Measurement And Control Device

  • RWB-7000L Line Protection Measurement And Control Device

Key attributes

Brand RW Energy
Model NO. RWB-7000L Line Protection Measurement And Control Device
Rated frequency 50(Hz)
Device power supply AC/DC 110/220V
Alternating current 5A or 1A
Series RWB

Product descriptions from the supplier

Description

 Overview:

The line protection measurement and control device is a complete set of line protection devices with current, voltage protection and three-phase reclosing as the basic configuration. It is suitable for the direction line protection and measurement and control in the non-direct grounding system or the resistance grounding system of the voltage level below 66kV, which can be installed in the switch cabinet or installed in the control room.

 Main function configuration:

  • Three-stage directional over-current protection blocking by compound voltage. 

  • Phase to phase Current Inverse Definite Minimum Time (IDMT) Limit Component (Standard inverse, Very inverse, Extremely inverse).

  • Three-stage directional zero sequence protection (independent tripping or alarm).

  • Zero sequence Inverse Definite Minimum Time (IDMT) Limit Component (Standard inverse, Very inverse, Extremely inverse).

  • Three-phase reclosing function.

  • Over-current acceleration protection and zero sequence acceleration protection (pre-acceleration and post-acceleration).

  • Overload component (independent tripping or alarm).

  • Under-frequency load shedding function. 

  • Low voltage and overvoltage protection component. 

  • CT break detection.

  • CT break detection. 

  • Control loop disconnection monitoring.

  • Measurement and control.

Main feature:

  • The device adopts a new generation of high-performance 32-bit CPU, so that the stability and computing speed of the product are fully guaranteed.

  • The acquisition module adopts 16-bit A/D converter, and the measurement and calculation indexes can easily meet the requirements.

  • A large-capacity storage module can record up to 32 wave recording reports, recording at least 1000 events, and maintaining power failure.

  •  The high precision clock chip ensures the accuracy of the clock when the device loses power.

  • Equipped with high-speed dual Ethernet communication interface.

  • Careful electrical design, the whole machine has no adjustable devices, to realize the concept of debugging.

  • High-grade, high-quality components selection.

  • Complete self-diagnosis function.

  • Case design with moisture, dust and vibration resistance. 

     

Technology parameters:

image.png

image.png

Device structure:

image.png

Device terminal definition diagram:

1.png

Installation Diagram:

29b699fe5248dffb3fc3c1e5482c44fe(1).jpg

 

 

FAQ
Q: How is the communication capability?
A:

Equipped with high-speed dual Ethernet interfaces (supporting IEC 61850 optional), far exceeding ordinary RS485 devices, meeting the requirements of intelligent substations for high bandwidth and low latency communication.

Q: Does it support directional protection?
A:

Yes, it is. Equipped with three-stage directional overcurrent protection and directional zero sequence protection, it can effectively distinguish faults within/outside the zone and improve selectivity.

Q: What voltage level is RWB-7000L suitable for?
A:

Suitable for non directly grounded or resistance grounded systems of 66kV and below, commonly used for main protection and measurement of transmission lines, busbars, or important feeders.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 30000m² Total staff: Highest Annual Export(usD): 100000000
Workplace: 30000m²
Total staff:
Highest Annual Export(usD): 100000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Robot
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Distribution automation systems solutions
    What are the difficulties in overhead line operation and maintenance?Difficulty one:Overhead lines of distribution network have wide coverage,complicatedterrain,many radiation branches and distributed power supply,resultingin "many line faults and difficulty in fault troubleshooting".Difficulty Two:Manual troubleshooting is time-consuming and laborious.Meanwhile,therunning current,voltage and switching state of the line cannot be graspedin real time,because of the lack of intelligent technical m
    04/22/2025
  • RW8000 DMS Distribution Management System Solutions
    OverviewNowadays, the development trend of power grid is intellectualization. As an important part of power grid, the power distribution system is very close to the customers and it has to run properly. The distribution management system (DMS)played an important role in it.Introduction:RW8000 power distribution management system (DMS) is designed for the smart grids. It is based on real-time application, centered on distribution network operation and management, focusing on the business process
    09/07/2023
  • High-Precision Electrical Parameter Monitoring System Solution
    1.Introduction​With the increasingly stringent requirements for power supply quality in high-end facilities such as precision manufacturing, medical diagnosis, and data centers, traditional power monitoring systems, due to their low sampling accuracy and weak data analysis capabilities, can no longer meet the demand for deep insight and precise management of power quality. In response, we are introducing a new generation ​High-Precision Electrical Parameter Monitoring System. With ​millisecond-l
    09/28/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.