• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


RWS-7000 Built - in bypass type motor soft starter

  • RWS-7000 Built - in bypass type motor soft starter

Key attributes

Brand RW Energy
Model NO. RWS-7000 Built - in bypass type motor soft starter
Rated current of star connection method 11A
Rated current of delta connection method 16A
Series RWS

Product descriptions from the supplier

Description

Description :

A bypass-type soft starter is a device specifically designed for the motor starting process, aiming to reduce start-up current and mechanical shock by controlling the voltage applied to the motor during startup. This type of soft starter gradually increases the voltage supplied to the motor, allowing it to smoothly accelerate to its rated speed without the large inrush currents and associated grid fluctuations that occur with direct-on-line starting.

Main function introduction:

  • SCRK1 - 7000 is a highly intelligent, reliable and easy to use soft starter. SCRK1 - 7000 is the perfect solution for quick settings or more personalized control, with features as follows:

  • Large LCD screen showing feedback in Chinese and English, other languages can be customized;

  • Remotely - mounted operating plate;

  • Intuitive programming;

  • Advanced start and stop control function;

  • A series of motor protection functions;

  • Extensive performance monitoring and event logging;

  • Positive rotation, point reversal function;

  • With the ability to upload/download parameters;

Technology parameters:

企业微信截图_17402077057249.png

Device structure:

image.png

Q:What is bypass in soft starter?

A:A bypass starter is a type of motor control system that combines the functionality of a soft starter with a bypass contactor. It is designed to provide smooth, controlled motor startup while allowing the motor to run directly from the power supply after it has reached full speed. This setup improves efficiency and reduces heat generation in the system.

Q: Is a VSD a soft starter?

A:A VSD (Variable - Speed Drive) is not a soft starter. A soft starter mainly eases a motor's startup by gradually increasing voltage to cut inrush current. In contrast, a VSD can control startup and continuously adjust motor speed by changing power frequency and voltage, offering more functionality.


FAQ
Q: Are the operations and parameter settings convenient?
A:

Equipped with a large LCD screen (displaying in both Chinese and English), supporting remote control panel and parameter upload/download, intuitive programming, and efficient debugging and maintenance.

Q: What start/stop modes does RWS-7000 support?
A:

Provide multiple modes such as current limiting start, voltage ramp, jump+ramp, pump control, free stop, soft stop, etc., and support forward and reverse rotation, jog function to adapt to complex working conditions.

Q: What is' built-in bypass'? What are the advantages?
A:

Built in bypass "refers to the automatic short circuiting of thyristors by internal contactors after startup, allowing the motor to be directly powered by the power grid. This can eliminate the conduction loss of thyristors, reduce temperature rise, and improve long-term operational efficiency.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 30000m² Total staff: Highest Annual Export(usD): 100000000
Workplace: 30000m²
Total staff:
Highest Annual Export(usD): 100000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Robot
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Distribution automation systems solutions
    What are the difficulties in overhead line operation and maintenance?Difficulty one:Overhead lines of distribution network have wide coverage,complicatedterrain,many radiation branches and distributed power supply,resultingin "many line faults and difficulty in fault troubleshooting".Difficulty Two:Manual troubleshooting is time-consuming and laborious.Meanwhile,therunning current,voltage and switching state of the line cannot be graspedin real time,because of the lack of intelligent technical m
    04/22/2025
  • RW8000 DMS Distribution Management System Solutions
    OverviewNowadays, the development trend of power grid is intellectualization. As an important part of power grid, the power distribution system is very close to the customers and it has to run properly. The distribution management system (DMS)played an important role in it.Introduction:RW8000 power distribution management system (DMS) is designed for the smart grids. It is based on real-time application, centered on distribution network operation and management, focusing on the business process
    09/07/2023
  • High-Precision Electrical Parameter Monitoring System Solution
    1.Introduction​With the increasingly stringent requirements for power supply quality in high-end facilities such as precision manufacturing, medical diagnosis, and data centers, traditional power monitoring systems, due to their low sampling accuracy and weak data analysis capabilities, can no longer meet the demand for deep insight and precise management of power quality. In response, we are introducing a new generation ​High-Precision Electrical Parameter Monitoring System. With ​millisecond-l
    09/28/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.