Key attributes

Brand ROCKWILL
Model NO. SF6 Insulated 3 Position Load Break Switch
Rated voltage 12kV
Rated normal current 630A
Rated frequency 50/60Hz
Series RPS-T

Product descriptions from the supplier

Description

Summary:

ROCKWILL® Electric​ is committed to providing customers with cutting-edge technology, competitive pricing, and superior after-sales services to advance automated distribution. As the power industry evolves, the miniaturization of electrical equipment represents a key future trend and an urgent need for current power consumers. Miniaturized electrical equipment not only saves land and civil engineering costs but also reduces the use of greenhouse gases like sulfur hexafluoride (SF6), thereby meeting ecological and environmental protection requirements. Leveraging years of extensive experience in high-voltage electrical design and incorporating globally advanced technical design philosophies, our company has developed the latest Three-Position Pole-Mounted Load Break Switch (RPS-T). This product is tailored for power utilities and enterprises pursuing high power supply reliability, advancing distribution automation upgrades, and operating in harsh environments. It serves not just as a simple line switch but as a critical component in building smart, resilient distribution grids.

Overall Description of the RPS-T Pole-Mounted Load Break Switch

  • Product Positioning and Core Advantages

The RPS-T is an SF₆ gas-insulated outdoor pole-mounted load break switch series launched by ROCKWILL, specifically designed for modern distribution automation. Its core advantages lie in high reliability, maintenance-free operation, and excellent environmental adaptability. Utilizing a sealed stainless steel tank and SF₆ gas insulation, it operates stably under harsh conditions such as salt spray, industrial pollution, ice, and snow, requiring no maintenance throughout its service life.

  • Product Series and Key Features

The series covers multiple voltage classes and functional requirements:

RPS-T12/24 630-20E:​ Equipped with a unique three-position structure, integrating two independent switches and one branch point, ideal for line branching and network reconfiguration.

All models support manual operation (insulated operating rod) or motor-driven operation (remote automation control), meeting diverse operational needs.

  • Design Highlights and Technical Features

Safety and Reliability:

  1. Grounded tank design eliminates leakage currents; large position indicators ensure clear visibility.
  2. Mechanical interlocks, gas density monitoring (density switch/pressure gauge), and other functions prevent misoperation.

Environmental Adaptability:

  1. Rated IP54protection, with a dustproof and waterproof mechanism enclosure.
  2. Constructed from stainless steel and anti-corrosion aluminum alloy for superior corrosion resistance.

Smart Expansion Capabilities:

  1. Compatible with add-on current transformers (CTs) and capacitive voltage dividers (CVDs) for load monitoring and voltage sensing.
  2. Comprehensive lightning arrester interfaces ensure robust overvoltage protection
  • Typical Application Scenarios
  1. Distribution Automation Segmentation:​Used for fault isolation in overhead lines and power restoration in non-fault zones.
  2. Line Branching and Ring Networks:​The RPS-T series optimizes branch connections, saving space and costs.
  3. Harsh Environments:​Suitable for coastal areas, extreme cold regions, industrial zones, and other locations where conventional equipment struggles to operate reliably.
  4. Space-Constrained Installations:​ Supports direct pole mounting, adapting to narrow or limited spaces.
  • The switch tank
  1. SF6 gas insulated switchgear is a three-phase linkage operation switch device designed for the distribution system cables and overhead power line segment applications.
  2. The switch body using welding to seal the casing and the casing using rubber ring seal, and all the other parts are assembled in the welding of stainless steel tank shell.
  3. The switch body designed to be able to withstand pressure without affecting the switch to normal operating performance.
  4. The shell casing is made of a thickness exceeding 3 mm cold-rolled stainless steel (SUS 304l) or better materials to withstand the internal gas pressure.
  5. SF6 gas is a kind of nontoxic, nonflammable and electrical insulating gas. It has the excellent characteristic of arc extinction.
  • Conclusion

With its modular design, multi-layered safety protection, and intelligent expansion capabilities, the RPS-T series serves as a key component in building smart distribution networks. Its compact structure, flexible installation options, and maintenance-free characteristics make it particularly suitable for power utilities pursuing enhanced reliability, automation upgrades, and resilience in challenging environments.

Main technical parameters

Insulation level

N

Item

Unit

Parameters

Parameters

1

Rated voltage

kV

12

24

2

Power frequency withstand voltage, 50 Hz

 

 

 

3

To earth and between phases

KV

42

50

4

Across the isolating distance

KV

48

60

5

Lightning impulse withstand voltage

 

 

 

6

To earth and between phases

KV

75

125

7

Across the isolating distance

KV

85

145

 

current ratings

N

Item

Unit

Parameters

Parameters

1

Rated normal current

A

630

630

2

Mainly active load breaking current

A

630

630

3

Number of breaking operations co

n

400

400

4

Line-charging breaking current

A

1.5

1.5

5

cable-charging breaking current

A

50

50

6

cable-charging breaking current

A

50

50

7

Under earth fault conditions

A

28

28

8

No-load transformer breaking current

A

6.3

6.3

 

short-circuit ratings

N

Item

Unit

Parameters

Parameters

1

short-time withstand current

KA/S

20KA/4S

20KA/4S

2

Peak withstand current

KA

50

50

3

Peak withstand current

KA

50

50

4

creepage distance

mm

620

620

5

Ambient air temperature limits

 

-40℃-+60℃

-40℃-+60℃

 

The appearance and size of the switch

Dimensions(mm)

Installation size

Casing creepage distance

 

A

B

C

Long x width

 

12KV

225

435

500

500x125(280)

556

24KV

300

435

500

500x125(280)

840

Ordering Information

Required to determine the product type, name, number, rated current, the operating power supply type, operating voltage

According to user requirements are available:

  • Ofthe terminal outlet or cable outlet.
  • The ceramic casing and the casing of organic insulator,
  • The ceramic casing and the casing of organic insulator,
  • Hanging bracket,

 

FAQ
Q: What are the core functions of an SF6 Insulated 3 Position Load Break Switch?
A:

The SF6 insulated 3-position load break switch integrates three key functions: load switching, circuit isolation, and earthing. Filled with SF6 gas for superior insulation and arc-extinguishing performance, it is widely applied in medium-voltage distribution grids to ensure safe, reliable power supply and support distribution automation upgrades.

Q: Why choose an SF6 Insulated 3 Position Load Break Switch for harsh environments?
A:

 SF6 gas offers excellent chemical stability and insulation properties, enabling the switch to operate reliably in high humidity, dusty, or extreme temperature conditions. Its compact, sealed design minimizes maintenance needs and prevents gas leakage, making it ideal for outdoor or industrial harsh working scenarios.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.