Solid insulated ring main unit accessories 234 Bushing

  • Solid insulated ring main unit accessories 234 Bushing

Key attributes

Brand Switchgear parts
Model NO. Solid insulated ring main unit accessories 234 Bushing
Rated voltage 12kV
Rated normal current 630A
Series 234

Product descriptions from the supplier

Description

234 bushing is a specialized core insulation accessory for 12kV/24kV SF6 free solid insulated ring main unit, adapted to the installation size of 234 specification. The core undertakes the function of line insulation protection and power transmission connection, and is a key connecting component of medium voltage distribution system.
Core Features
Using pure solid insulation material, without SF6 gas and oil medium, without leakage or explosion risk, in line with green distribution and environmental protection requirements, the insulation performance meets IEC standards.
The size accurately matches the 234 specification installation interface, with a compact structure and high mechanical strength. It is resistant to impact and aging, and can adapt to long-term stable operation needs.
Excellent sealing and protection design, moisture-proof, dustproof, corrosion-resistant, suitable for complex working environments such as distribution rooms, industrial plants, underground substations, etc.
Easy to install without additional maintenance, with wiring interfaces that comply with medium voltage distribution standards, ensuring secure line connections and reducing the risk of poor contact.
Applicable scenarios
Suitable for 12kV/24kV SF6 free solid insulated ring main unit, used for cabinet incoming and outgoing lines, PT circuits, busbar connections and other scenarios, widely used in medium voltage distribution systems such as urban distribution networks, industrial distribution, and new energy power stations.

Product dimensions

FAQ
Q: Are there special requirements for installation of 234 Bushing for solid insulated RMU?
A:

Key requirements (professional electricians required): ① Pre-installation preparation: Clean the bushing’s insulation surface and RMU’s installation hole to remove dust, oil stains and oxide layer, avoiding insulation reduction; ② Installation operation: Install the bushing vertically/horizontally as required, ensure tight fit with the installation hole, and fasten the fixing bolts evenly (torque meets specifications) to prevent tilting; ③ Conductor connection: Connect the conductor to the bushing’s terminal firmly, ensure good contact to avoid overheating due to poor contact;

Q: What is the core function and working principle of 234 Bushing for solid insulated RMU?
A:

 As a key insulation accessory for solid insulated ring main units (RMU), its core functions are: ① Electrical insulation: Isolate high-voltage conductors from the RMU cabinet to prevent leakage current and ensure operation safety; ② Conductor connection: Realize reliable electrical connection between internal and external conductors of the solid insulated RMU, ensuring stable current transmission. Working principle: It adopts high-performance solid insulation material (epoxy resin) as the main insulation medium, with metal conductors embedded inside; the insulation layer effectively blocks high-voltage breakdown

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.