• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Special Side-Expanding Bushing for Solid Insulated Switchgear

  • Special Side-Expanding Bushing for Solid Insulated Switchgear
  • Special Side-Expanding Bushing for Solid Insulated Switchgear

Key attributes

Brand Switchgear parts
Model NO. Special Side-Expanding Bushing for Solid Insulated Switchgear
Rated voltage 12kV
Rated normal current 630A
Series RNCK

Product descriptions from the supplier

Description

Side width is a critical component of solid insulated cabinets, specifically referring to the width of the cabinet's side, suitable for 12kV/24kV medium voltage distribution scenarios.
Core Features
Accurately matching the overall structure of the solid insulation cabinet to ensure installation compatibility with other components.
Based on the insulation design requirements of the cabinet, taking into account the utilization of installation space and insulation protection performance, it is suitable for scenarios such as power distribution rooms and industrial plants.

Precautions for side width installation of solid insulation cabinet

1、 Size adaptation verification
Before installation, confirm that the actual dimensions of the side width are consistent with the cabinet design drawings, and the deviation should be controlled within ± 2mm to avoid interference with adjacent components such as busbars and sleeves.
Check the compatibility between the side width and the installation foundation (such as brackets and guide rails) to ensure that the support points are fully aligned with the side width stress surface and there is no hanging situation.
2、 Insulation protection guarantee
The installation surface of the side width should be kept clean and dry, free of impurities such as oil stains and metal debris, to prevent affecting the overall insulation performance of the cabinet.
During installation, avoid scratching the insulation coating on the side wide surface. If there is any damage, it should be repaired promptly with specialized insulation materials that comply with relevant IEC insulation standards.
3、 Space and layout requirements
A maintenance space of ≥ 10cm should be reserved on both sides of the side width, taking into account subsequent maintenance and heat dissipation, and avoiding close contact with walls or other equipment.
When multiple cabinets are installed in parallel, the standard for side width dimensions should be unified to ensure that the cabinets are arranged neatly and the spacing between adjacent cabinets is even, without affecting switch operation and circuit connection.
4、 Fixed and stress specifications
Special fasteners are used to fix the side width, and the tightening torque meets the requirements of the product manual (usually 8-12N · m) to avoid component deformation caused by over tightening.
After installation, check the verticality of the side width, with a deviation of ≤ 3 ‰, to prevent long-term uneven stress from affecting the stability of the cabinet structure.

Overall dimensions

FAQ
Q: What safety precautions should be taken when using this side-expanding bushing?
A:

Key precautions to avoid electrical hazards: ① Power-off operation: Cut off the power supply and implement lockout-tagout before installation, maintenance or replacement; ② Protective equipment: Wear insulated gloves and insulated shoes during operation, do not touch live parts; ③ Avoid overload: Do not exceed the rated current and voltage to prevent insulation breakdown and overheating; ④ Transportation protection: Use shockproof packaging to avoid collision and extrusion damage to the bushing; ⑤ Regular inspection: Strengthen inspections in vibration-prone environments to prevent connection loosening and arcing....

Q: What are the core functions and working principles?
A:

 It is a specialized insulation accessory for solid insulated switchgear (SIS) and ring main units (RMU). Core functions: ① Lateral conductor connection and insulation isolation between internal and external components of the switchgear; ② Side-expanding structure adapts to narrow installation spaces, optimizing the layout of the switchgear cabinet; ③ Preventing leakage current and pollution flashover. Working principle: Adopt high-strength epoxy resin APG casting process, the side-expanding structure increases creepage distance; the embedded metal conductor realizes current transmission, and the solid insulation layer blocks high-voltage breakdown, fully matching the SF6-free design of SIS.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.