Surge Arresters for AC Filters

  • Surge Arresters for AC Filters

Key attributes

Brand ROCKWILL
Model NO. Surge Arresters for AC Filters
Rated voltage 145kV
Rated frequency 50/60Hz
Series Y10W

Product descriptions from the supplier

Description

Description

Surge Arresters for AC Filters are specialized protective devices designed to safeguard AC filter systems in power grids, particularly in high-voltage transmission and distribution networks as well as converter stations. These arresters are installed in conjunction with AC filters, which are responsible for mitigating harmonic currents and improving power quality. They effectively suppress transient overvoltages that may occur in AC filter circuits due to lightning strikes, switching operations, system faults, or harmonic resonance. By rapidly diverting surge currents to the ground and clamping the voltage to a safe level, Surge Arresters for AC Filters prevent damage to filter components such as capacitors, reactors, and resistors, ensuring the stable operation of the AC filter system and thus maintaining the overall power quality and reliability of the power grid.

Features

  • Optimized for AC Filter CircuitsTailored to the specific electrical characteristics of AC filter systems, including the presence of harmonic frequencies and unique impedance properties. They are designed to handle the particular overvoltage scenarios that arise in these circuits, providing precise and effective protection without interfering with the normal filtering function.

  • Excellent Harmonic ResilienceCapable of operating stably in environments with high harmonic content. The internal components, especially the metal oxide varistors (MOVs), are designed to withstand the stress caused by harmonic currents and voltages, ensuring reliable performance even in the presence of significant harmonic distortion.

  • Rapid Response to TransientsEquipped with high-performance MOVs that have an ultra-fast response time to transient overvoltages. This quick reaction is crucial in AC filter systems, where even short-duration overvoltages can damage sensitive components, ensuring that surges are clamped before they can cause harm.

  • High Energy Absorption CapacityAble to absorb large amounts of energy from severe surge events, such as those caused by direct lightning strikes or major system faults. This high energy handling capability ensures that the arrester can effectively mitigate the impact of such events, protecting the AC filter components from damage.

  • Durable and Weather-Resistant ConstructionHoused in robust materials, such as composite silicone rubber or porcelain, which offer excellent resistance to environmental factors including UV radiation, extreme temperatures, moisture, and pollution. This durability ensures long-term reliable operation in both indoor and outdoor installations, reducing maintenance requirements.

  • Low Leakage CurrentExhibits minimal leakage current during normal operation, which helps to minimize power loss and prevent unnecessary heating. This is important for maintaining the efficiency of the AC filter system and ensuring that the arrester does not interfere with the normal operation of the filter.

  • Compliance with Industry StandardsManufactured in accordance with relevant international standards, such as IEC and IEEE standards, ensuring that they meet strict performance and safety criteria. Compliance with these standards guarantees that the arresters are compatible with AC filter systems worldwide and can be relied upon for effective protection.

  • Easy Integration with Filter SystemsDesigned with dimensions and mounting configurations that allow for easy integration into existing AC filter systems. This simplifies installation and ensures that the arrester can be seamlessly incorporated into the filter circuit without requiring major modifications to the system.

Model 

Arrester

System

Arrester Continuous Operation

DC 1mA

Switching Impulse

Nominal Impulse

Steep - Front Impulse

2ms Square Wave

Nominal

Rated Voltage

Nominal Voltage

Operating Voltage

Reference Voltage

Voltage Residual (Switching Impulse)

Voltage Residual (Nominal Impulse)

Current Residual Voltage

Current - Withstand Capacity

Creepage Distance

kV

kV

kV

kV

kV

kV

kV

A

mm

(RMS Value)

(RMS Value)

(RMS Value)

Not Less Than

Not Greater Than

Not Greater Than

Not Greater Than

20 Times






(Peak Value

(Peak Value

(Peak Value

(Peak Value


Y88W1-132/353W

132


110

191/3

305

353


2400

4500

Y10W1-23/55W

23


18.4

32/5

49

55


5000

2370

Y10W1-23/55W

23


18.4

32/4

53

55


4000

2370

Y10W1-23/55W

23


18.4

32/1

45

55


600

1256

Y76W1-71/194W

71


56

102/4

157

194


2400

2500

Y85W1-125/340W

125


100

182/6


340


6000

5320

Y83W1-85/339W

85


68

124/2


339


5000

4335

Y82W1-70/338W

70


56

102/2


338


5000

4335

Y71W1-145/408W

145


120

210/4

327

408


2400

6000

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.