• The Voltage Tester 6V-400V Electricians And DIYers To Measure AC/DC Voltage
  • The Voltage Tester 6V-400V Electricians And DIYers To Measure AC/DC Voltage
  • The Voltage Tester 6V-400V Electricians And DIYers To Measure AC/DC Voltage
  • The Voltage Tester 6V-400V Electricians And DIYers To Measure AC/DC Voltage
The Voltage Tester 6V-400V Electricians And DIYers To Measure AC/DC Voltage
$11.00
Model
MDT-400DP
MDT-230DP
MDT-120DP
MDT-50DP
MDT-24DP
MDT-12DP
Basic info
Brand Wone
Model NO. UT22B-EU Voltage Tester 6V-400V Electricians And DIYers To Measure AC/DC Voltage
Frequency range 50/60Hz
Voltage range 17V~24V
Series MDT 22B-EU
Product Detail

Description

The UT22B-EU voltage tester is a simple to use tool for electricians and DIYers to measure AC/DC voltage. This voltage tester is IP54 rated, and designed to withstand a 2-meter drop. The great thing about this product is that it does not require any battery, its power is supplied by the voltage being tested! UT22B can automatically distinguish between AC and DC voltage, indicated by the number of LED lights.

Feature

 Certifications: CE, UKCA

  •  Automatically detect AC/DC voltage

  •  Automatically indicate DC polarity (+/-)

  •  Hazardous voltage indicator when voltage >50V

  •  Auto detection of AC/DC

  •  Input protection

Specifications


image.png

image.png

image.png

How the input protection circuitry in the voltage tester is protected?

  • Overcurrent Protection: When the input current exceeds the rated value of the fuse or current-limiting resistor, the fuse will blow or the current-limiting resistor will restrict the current, preventing damage to the tester from overcurrent.

  • Overvoltage Protection: Clamping diodes and Transient Voltage Suppression (TVS) diodes can quickly conduct when the voltage exceeds a certain threshold, absorbing or diverting excess voltage energy to protect the internal circuitry from damage.

  • Electrical Isolation: An isolation transformer can electrically isolate the input signal from the internal circuitry of the tester, preventing high voltage from directly entering the tester, causing damage or posing a threat to personal safety.

  • Filtering: Capacitors can filter out high-frequency noise from the input signal, preventing this noise from interfering with the normal operation of the tester.

  • Comprehensive Protection: Input protection circuits typically employ a combination of the above components and technologies, forming a multi-layered protection mechanism to ensure that the tester can operate safely under various adverse conditions.








Know your supplier
Wone
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!