VANP 2P Voltage – current protector

  • VANP 2P Voltage – current protector
  • VANP 2P Voltage – current protector
  • VANP 2P Voltage – current protector

Key attributes

Brand Switchgear parts
Model NO. VANP 2P Voltage – current protector
Rated voltage AC220V
Rated normal current 40A
Rated frequency 50/60Hz
Series VANP

Product descriptions from the supplier

Description

Product Introduction: VANP-2P is an intelligent 2P overvoltage and undervoltage protection device suitable for single-phase AC 220V/50-60Hz power grid environment. It integrates overvoltage protection, undervoltage protection, and overcurrent protection functions. By accurately monitoring the line voltage and current, it quickly acts and cuts off the circuit when abnormal situations beyond the safe range are detected; After the power grid parameters return to normal, it can automatically reset and connect according to the set time, providing continuous security for the backend load.

VANP-2P self resetting overvoltage and undervoltage protector product features:
1. Precise monitoring and rapid response:
Adopting high-precision voltage detection circuit (with an error not exceeding 2% of the total range), it can sensitively perceive small changes in grid voltage. When the abnormal voltage reaches the set threshold (overvoltage ≥ 230V, undervoltage ≤ 140V), the device can quickly cut off the power supply within the set tripping delay time (adjustable from 0.1 seconds to 30 seconds), effectively suppressing the impact of abnormal voltage on sensitive equipment.
2. Intelligent recovery management:
Different from disposable protective devices, it has intelligent self reset function. After the grid voltage stabilizes and returns to the safe range (140V-210V), the device will automatically close again according to the preset reset delay time (adjustable from 1 second to 500 seconds) to restore power supply. This design not only avoids frequent disconnections caused by brief fluctuations in the power grid, but also ensures the stability of power supply recovery.
3. Integrated overcurrent protection:
In addition to voltage protection, the integrated overcurrent protection function (current setting range 1~63A) provides more circuit safety protection and prevents accidents caused by line overload or short circuit.
4. High reliability and long lifespan design:
The core components and structural design focus on durability, with an electrical lifespan of up to 100000 operations and a mechanical lifespan of up to 1000000 operations, reducing maintenance costs and replacement frequency, making it suitable for situations that require long-term reliable operation.
5. Flexible parameter configuration:
Users can flexibly set the overvoltage and undervoltage action threshold, as well as the tripping delay, based on the actual characteristics of the electrical equipment and the power grid conditions
Realize personalized customization of protection strategies with delay time for interval and reset

Technical data


Rated supply voltage

AC 220V

Operation voltage range

AC 80V - 400V (single phase)

Rated frequency

50/60Hz

Electric current (>A) setting range

1 - 40/63A

Overvoltage (>U) setting range

230 - 300V

Undervoltage (<U) setting range

210 - 140V

Rated current

40/63A (subject to product label)

>U and <U trip delay

0.5S

Reset/start delay

1 - 600S

Voltage measurement accuracy

2% (Not exceeding 2% of the overall range)

Rated insulation voltage

400V

Output contact

1NO

Electrical life


Mechanical life


Protection degree

Ip20

Pollution degree

3

Altitude

≤2000m

Operating temperature

-50°C - 55°C

Humidity

≤50% at 40°C (without condensation)

Storage temperature

-30°C - 70°C

Documentation Resource Library
Restricted
VANP-2P-catalog
Catalogue
English
Consulting
Consulting
FAQ
Q: What are the operating specifications for this protector? How to quickly adjust parameters and save them?
A:

The operation needs to be achieved through the device buttons. Click the SET button to enter the parameter setting menu, short press the plus or minus button to fine tune the values, and long press the plus or minus button to quickly adjust; After all parameter settings are completed, press and hold the SET button for 5 seconds to save and take effect; The overvoltage, undervoltage, and overcurrent protection functions support independent setting to OFF state, and the number of continuous overcurrent protection times can be selected between A01-A20/OFF

Q: What are the core protection parameters (overvoltage, undervoltage, overcurrent) setting ranges and factory default values of voltage and current protectors?
A:

The overvoltage protection setting range is 230V-300V, with a factory default of 280V; the undervoltage protection setting range is 140V-210V, with a factory default of 160V; the overcurrent protection setting range is 1A-40A/63A (corresponding to the rated current specification), with a factory default of 40A/63A; The overvoltage/undervoltage trip delay is both 0.5S, and the overcurrent trip delay is 5S.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.