Optimizing New Energy Usage: The Industrial and Commercial Energy Storage Solution for Peak Shaving, Grid Stability & Savings

Rockwill
17yrs 700++ staff 108000m²+m² US$150,000,000+ China

Ⅰ. Executive Summary
As the global energy transition accelerates, Industrial & Commercial Energy Storage Systems (ICESS) have emerged as a critical solution to address peak-valley electricity price gaps, grid fluctuations, and renewable energy integration. By combining new energy generation (e.g., solar PV, wind power) with smart grid technologies, ICESS optimizes energy management. This modular-designed solution covers the entire chain from technology selection to commercial implementation, delivering an economically viable and safety-compliant energy management system for enterprises.

II. Problem Statement: Key Energy Challenges for Industrial & Commercial Users

  1. High Electricity Costs:​ Peak-valley price gaps exceed RMB 0.7/kWh, with peak tariffs accounting for 72% of corporate electricity expenses.
  2. Grid Instability:​ Power curtailments and voltage fluctuations cause production downtime and efficiency losses.
  3. Low Renewable Energy Utilization:​ On-site solar PV self-consumption rates average only 30%, while grid feed-in tariffs yield minimal revenue.
  4. Grid Capacity Pressure:​ Short-duration load peaks force costly grid upgrades (e.g., transformer replacements).

III. Solution: ICESS System Architecture
1. Core Components & Technology Selection

Component

Technical Solution

Function & Advantage

Battery System

LFP Batteries (mainstream), Flow Batteries (long-duration)

High cycle life (>6,000 cycles), safety & stability (UL9540 certified)

Power Conversion System (PCS)

Bi-directional Inverter

AC/DC conversion, response speed <100ms, supports grid-tied/off-grid switching

Energy Management System (EMS)

Intelligent EMS Platform

Real-time charge/discharge optimization using tariff signals & load forecasts to enhance ROI

Thermal Management & Fire Protection

Liquid Cooling + HFC-227ea Fire Suppression

Temperature control (5–30°C), zero-delay fire suppression (NFPA855 compliant)

2. System Integration Design

  • Modular Cabinets:​ Single cabinet capacity: 500kWh–1MWh, supports parallel expansion (e.g., 4MWh system requires 4–8 cabinets).
  • Multi-Energy Integration:
     ​PV-Storage Synergy:​ Increases solar PV self-consumption to 80%;
     ​Storage-Charging Coordination:​ Mitigates EV fast-charging load impacts, reducing transformer stress.

IV. Application Scenarios & Business Models
1. Typical Scenarios

Scenario

Solution

Case Benefit

Energy-Intensive Factory

Peak shaving + Demand charge management

Saves RMB 2M/year (1MW/2MWh system)

Commercial Complex

HVAC load shifting + PV coordination

Reduces costs by 30%, cuts 100 tons CO₂/year

PV-Storage Charging Station

Buffers fast-charging loads + arbitrage

Payback period <4 years

Microgrid/Off-Grid

Diesel generator replacement (islands, mines)

Reduces diesel dependency by 70%

2. Economic Analysis

  • Cost Savings:
    o ​Price Arbitrage:​ Leverages tariff gaps (RMB 0.7/kWh) to cut electricity costs by 15–30%;
    o ​Demand Charge Management:​ Reduces capacity-based fees (applicable for >315kVA transformers).
  • ROI Analysis:
    • Initial Investment: RMB 5M (1MW system);
    • Payback Period: 3–5 years (subject to local subsidies & tariff policies).

V. Implementation Roadmap

  1. Demand Assessment:​ Analyze 12 months of electricity data to map load profiles and peak/off-peak patterns.
  2. System Design:
    o ​Capacity Calculation:​ Storage capacity = Avg. daily peak consumption × DoD (85%) × System efficiency (88%);
    o ​Site Selection:​ Proximity to renewable sources or load centers.
  3. Deployment & O&M:
    o Modular installation (project timeline <30 days);
    o Smart Monitoring: BMS+EMS real-time alerts, O&M cost <2% of CAPEX/year.

VI. Case Study: Electronics Manufacturing Plant

  • Challenge:​ Daytime peak load 2× higher than nighttime, with peak tariffs comprising 72% of electricity costs.
  • Solution:​ 300kW power / 500kWh capacity LFP battery system deployed.
  • Results:
    • Annual electricity cost reduction: 20%;
    • Solar PV self-consumption rate increased to 80%;
    • 4-hour emergency backup for critical production lines.
06/26/2025
Recommended
Solution for Medium-Voltage Motor Control and Protection Using Vacuum Contactor-Fuse (VCF) in a Coal Conveying System
Project BackgroundA coal conveying system comprises 15 belt conveyors driven by medium-voltage motors. The system operates under complex conditions, with motors often subjected to heavy loads and frequent starts. To address these challenges and achieve effective control and reliable protection during motor startup, the project comprehensively adopts Vacuum Contactor-Fuse (VCF) combination devices for the 6kV medium-voltage motor power distribution. This solution details the technical features,
ABB Vacuum Contactor KC2 Power Supply System Technical Transformation Plan
Issue Overview​The 10kV air compressor starting system of a company utilizes the ABB vacuum contactor KC2 as the control component for the operating circuit. The dedicated wide-voltage power supply module paired with this contactor presents the following issues:​Frequent failures: The power supply module fails to properly transition the voltage from 300V to 12V, resulting in fuse blowouts.​Poor heat dissipation: Enclosed installation of the module leads to insufficient heat dissipation, acceler
Dedicated Vacuum Contactor Solution for Port Shore Power Systems
I. Background and Challenges​Shore power systems have become core technical equipment for ports to reduce carbon emissions and noise pollution. However, these systems face two major challenges in the harsh operational environment of ports:​Severe Environmental Corrosion: High humidity and salt spray in port areas cause serious corrosion to metal components and enclosures of electrical equipment, significantly impacting electrical lifespan and operational reliability.​High Switching Requirements:
Vacuum Contactor Industrial Power Control Solutions
Application Background and Pain Point Analysis​In modern industrial manufacturing power control systems, traditional contactors exhibit significant limitations under specific operating conditions:• ​Frequent Start-Stop Operations: Traditional contactors have limited mechanical lifespan, with frequent operations leading to coil burnout and mechanical jamming.• ​Poor Adaptability to Harsh Environments: Contacts are prone to oxidation in dusty environments, resulting in increased contact
Seed Inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.