Why not use superconductors as transformer winding materials to achieve zero loss?

Encyclopedia
09/29/2024

Superconductors, as a material that can theoretically achieve zero-resistance transmission, do have great potential, especially in the field of power transmission, to significantly reduce energy loss. However, the application of superconductors to transformer winding materials is not a simple solution due to the technical, economic and practical complexities involved. Here are a few key factors:


  • Critical temperature limit: Superconductors need to operate at certain low temperatures to exhibit superconducting properties, typically reaching temperatures close to absolute zero. This means that complex cooling systems are required to maintain the superconducting state, which increases the cost and complexity of the equipment and makes it difficult to achieve long-term stable operation in practical applications.



  • Cost and Availability of materials: Although some superconducting materials have been discovered and synthesized, not all superconducting materials are suitable for large-scale industrial production. The preparation process of some superconducting materials is complex and costly, which limits their large-scale application.



  • Technical challenges: Achieving superconductivity at room temperature and atmospheric pressure remains an unsolved problem. Although some materials have been reported to show diamagnetism (the Meissner effect) under certain conditions, this does not automatically mean that they have zero resistance. Moreover, even if superconductors are successfully prepared under laboratory conditions, technical difficulties may be encountered during replication and mass production.



  • Economic feasibility: Considering the vast infrastructure of the current power system, a full replacement with superconducting materials would require significant initial investment and retrofit costs. In addition, while the energy savings of superconducting materials in long-term operation are significant, the initial investment and maintenance costs can take a long time to recover the investment.



  • Safety and reliability: The stability of superconducting materials under extreme conditions still needs further study. For example, sudden power outages or temperature changes can cause materials to lose superconductivity, an important safety consideration in power systems.



In summary, although superconductors offer the potential of lossless transmission in theory, the technical, economic and operational challenges in practical applications have prevented the widespread adoption of superconductors as transformer winding materials. As technology advances and new materials are discovered, more viable solutions may emerge in the future, but they are still in the exploratory phase.


Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
Frequency division method for measuring grid-to-ground insulation parameters
Frequency division method for measuring grid-to-ground insulation parameters
The frequency division method enables the measurement of grid-to-ground parameters by injecting a current signal of a different frequency into the open delta side of the potential transformer (PT).This method is applicable to ungrounded systems; however, when measuring the grid-to-ground parameters of a system where the neutral point is grounded via an arc suppression coil, the arc suppression coil must be disconnected from operation beforehand. Its measurement principle is shown in Figure 1.As
Leon
07/25/2025
The insulation parameters of the power grid to ground are measured by the tuning method
The insulation parameters of the power grid to ground are measured by the tuning method
The tuning method is suitable for measuring the ground parameters of systems where the neutral point is grounded via an arc suppression coil, but not applicable to ungrounded neutral point systems. Its measurement principle involves injecting a current signal with continuously varying frequency from the secondary side of the Potential Transformer (PT), measuring the returned voltage signal, and identifying the system's resonant frequency.During the frequency sweeping process, each injected heter
Leon
07/25/2025
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
In an arc - suppression coil grounding system, the rising speed of the zero - sequence voltage is greatly affected by the value of the transition resistance at the grounding point. The larger the transition resistance at the grounding point, the slower the rising speed of the zero - sequence voltage.In an ungrounded system, the transition resistance at the grounding point has basically no impact on the rising speed of the zero - sequence voltage.Simulation Analysis: Arc - suppression Coil Ground