What causes harmonics in electrical systems?

Encyclopedia
Field: Encyclopedia
0
China

Harmonics in electrical systems are caused by nonlinear loads that produce non-sinusoidal waveforms of current or voltage in alternating current systems. Harmonics are sine wave components with integral multiples of frequencies other than fundamental frequencies. The following are some of the main causes of harmonics in electrical systems:

Nonlinear load

Nonlinear loads are those in which the current is not linearly related to the voltage. This type of load is common in the power system, and the main sources include:

  • Rectifier: A device used to convert alternating current to direct current, such as a power adapter, frequency converter, etc.

  • Switching power supply: The power supply commonly used in modern electronic equipment, such as computer power supplies, mobile phone chargers, etc.

  • Inverter: A device used to convert direct current to alternating current, commonly found in solar photovoltaic systems, electric vehicle charging stations, etc.

  • Variable frequency driver: a device used to control the speed of a motor, widely used in the field of industrial automation.

  • Arc welding machine: Nonlinear current is generated during the welding process.

  • Gas discharge lamps: such as fluorescent lamps, high-pressure sodium lamps, etc., will produce harmonics during start-up and operation.

Power electronic equipment

Power electronic devices widely used in modern power systems are also important sources of harmonics:

  • Frequency converter: used to control the speed and torque of the AC motor, its working principle will produce harmonics.

  • UPS (Uninterruptible Power Supply) : Harmonics are generated when switching to battery powered mode.

  • Converter: A device used to change the frequency of alternating current, such as a converter used in wind power generation.

Motors and transformers

Even in traditional motors and transformers, slight harmonics may occur due to reasons such as magnetic saturation effects:

  • Motors: Especially in the start-up phase, harmonics may be generated due to the influence of nonlinear magnetization curves.

  • Transformer: When the transformer works in the saturated area, it will also produce harmonics.

Problems with the grid itself

  • Unbalanced load: An unbalanced load in a three-phase system can cause the neutral current to contain harmonics.

  • Long-distance transmission: In the process of long-distance transmission, the inductance and capacitance effects of the line may lead to the amplification of harmonics.

Other factors

  • Aging of power equipment: Older power equipment may produce additional harmonics due to degradation of internal components.

  • Design Flaws: Poorly designed power systems can lead to amplification or generation of harmonics.

Harmonic effect

Harmonics can cause a variety of adverse effects on power systems, including but not limited to:

  • Increased equipment losses: Harmonics can lead to additional losses of motors, transformers and other equipment, shortening the service life.

  • Reduce system efficiency: Harmonics can reduce system efficiency and increase energy consumption.

  • Affect the measurement accuracy: Harmonics will interfere with the measurement accuracy of the energy meter, resulting in incorrect calculation of electricity charges.

  • Interference with the communication system: Harmonics will cause interference to the communication system and affect the quality of signal transmission.

  • Triggering resonance: In some cases, harmonics can resonate with inductors and capacitors in the system, causing serious power quality problems.

Harmonic suppression measure

In order to reduce the impact of harmonics, the following measures are usually taken:

  • Filters: Install passive or active filters to absorb or counteract harmonics.

  • Increase the inductance of the load: By increasing the inductance of the load to suppress harmonics.

  • Improve load characteristics: Use a load with low harmonic content, such as a three-phase rectifier instead of a single-phase rectifier.

  • Dynamic reactive power compensation: Use equipment such as SVG (static reactive power generator) for dynamic reactive power compensation.

Sum up

Harmonics in electrical systems are mainly caused by nonlinear loads, such as rectifiers, switching power supplies, inverters, variable frequency drivers, etc. Harmonics can negatively affect the performance and reliability of the power system, so it is necessary to take appropriate measures to suppress or eliminate harmonics.

Give a tip and encourage the author!

Recommended

Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
01/29/2026
Understanding Transformer Neutral Grounding
I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
01/29/2026
Voltage Imbalance: Ground Fault, Open Line, or Resonance?
Single-phase grounding, line break (open-phase), and resonance can all cause three-phase voltage unbalance. Correctly distinguishing among them is essential for rapid troubleshooting.Single-Phase GroundingAlthough single-phase grounding causes three-phase voltage unbalance, the line-to-line voltage magnitude remains unchanged. It can be classified into two types: metallic grounding and non-metallic grounding. Inmetallic grounding, the faulted phase voltage drops to zero, while the other two phas
11/08/2025
Composition and Working Principle of Photovoltaic Power Generation Systems
Composition and Working Principle of Photovoltaic (PV) Power Generation SystemsA photovoltaic (PV) power generation system is primarily composed of PV modules, a controller, an inverter, batteries, and other accessories (batteries are not required for grid-connected systems). Based on whether it relies on the public power grid, PV systems are divided into off-grid and grid-connected types. Off-grid systems operate independently without relying on the utility grid. They are equipped with energy-s
10/09/2025
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.