What causes harmonics in electrical systems?

Encyclopedia
09/30/2024

Harmonics in electrical systems are caused by nonlinear loads that produce non-sinusoidal waveforms of current or voltage in alternating current systems. Harmonics are sine wave components with integral multiples of frequencies other than fundamental frequencies. The following are some of the main causes of harmonics in electrical systems:


Nonlinear load


Nonlinear loads are those in which the current is not linearly related to the voltage. This type of load is common in the power system, and the main sources include:


  • Rectifier: A device used to convert alternating current to direct current, such as a power adapter, frequency converter, etc.


  • Switching power supply: The power supply commonly used in modern electronic equipment, such as computer power supplies, mobile phone chargers, etc.


  • Inverter: A device used to convert direct current to alternating current, commonly found in solar photovoltaic systems, electric vehicle charging stations, etc.


  • Variable frequency driver: a device used to control the speed of a motor, widely used in the field of industrial automation.


  • Arc welding machine: Nonlinear current is generated during the welding process.


  • Gas discharge lamps: such as fluorescent lamps, high-pressure sodium lamps, etc., will produce harmonics during start-up and operation.



Power electronic equipment


Power electronic devices widely used in modern power systems are also important sources of harmonics:


  • Frequency converter: used to control the speed and torque of the AC motor, its working principle will produce harmonics.


  • UPS (Uninterruptible Power Supply) : Harmonics are generated when switching to battery powered mode.


  • Converter: A device used to change the frequency of alternating current, such as a converter used in wind power generation.



Motors and transformers


Even in traditional motors and transformers, slight harmonics may occur due to reasons such as magnetic saturation effects:


  • Motors: Especially in the start-up phase, harmonics may be generated due to the influence of nonlinear magnetization curves.


  • Transformer: When the transformer works in the saturated area, it will also produce harmonics.


Problems with the grid itself


  • Unbalanced load: An unbalanced load in a three-phase system can cause the neutral current to contain harmonics.


  • Long-distance transmission: In the process of long-distance transmission, the inductance and capacitance effects of the line may lead to the amplification of harmonics.



Other factors


  • Aging of power equipment: Older power equipment may produce additional harmonics due to degradation of internal components.


  • Design Flaws: Poorly designed power systems can lead to amplification or generation of harmonics.



Harmonic effect


Harmonics can cause a variety of adverse effects on power systems, including but not limited to:


  • Increased equipment losses: Harmonics can lead to additional losses of motors, transformers and other equipment, shortening the service life.


  • Reduce system efficiency: Harmonics can reduce system efficiency and increase energy consumption.


  • Affect the measurement accuracy: Harmonics will interfere with the measurement accuracy of the energy meter, resulting in incorrect calculation of electricity charges.


  • Interference with the communication system: Harmonics will cause interference to the communication system and affect the quality of signal transmission.


  • Triggering resonance: In some cases, harmonics can resonate with inductors and capacitors in the system, causing serious power quality problems.


Harmonic suppression measure


In order to reduce the impact of harmonics, the following measures are usually taken:


  • Filters: Install passive or active filters to absorb or counteract harmonics.


  • Increase the inductance of the load: By increasing the inductance of the load to suppress harmonics.


  • Improve load characteristics: Use a load with low harmonic content, such as a three-phase rectifier instead of a single-phase rectifier.


  • Dynamic reactive power compensation: Use equipment such as SVG (static reactive power generator) for dynamic reactive power compensation.



Sum up


Harmonics in electrical systems are mainly caused by nonlinear loads, such as rectifiers, switching power supplies, inverters, variable frequency drivers, etc. Harmonics can negatively affect the performance and reliability of the power system, so it is necessary to take appropriate measures to suppress or eliminate harmonics.


Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
Frequency division method for measuring grid-to-ground insulation parameters
Frequency division method for measuring grid-to-ground insulation parameters
The frequency division method enables the measurement of grid-to-ground parameters by injecting a current signal of a different frequency into the open delta side of the potential transformer (PT).This method is applicable to ungrounded systems; however, when measuring the grid-to-ground parameters of a system where the neutral point is grounded via an arc suppression coil, the arc suppression coil must be disconnected from operation beforehand. Its measurement principle is shown in Figure 1.As
Leon
07/25/2025
The insulation parameters of the power grid to ground are measured by the tuning method
The insulation parameters of the power grid to ground are measured by the tuning method
The tuning method is suitable for measuring the ground parameters of systems where the neutral point is grounded via an arc suppression coil, but not applicable to ungrounded neutral point systems. Its measurement principle involves injecting a current signal with continuously varying frequency from the secondary side of the Potential Transformer (PT), measuring the returned voltage signal, and identifying the system's resonant frequency.During the frequency sweeping process, each injected heter
Leon
07/25/2025
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
In an arc - suppression coil grounding system, the rising speed of the zero - sequence voltage is greatly affected by the value of the transition resistance at the grounding point. The larger the transition resistance at the grounding point, the slower the rising speed of the zero - sequence voltage.In an ungrounded system, the transition resistance at the grounding point has basically no impact on the rising speed of the zero - sequence voltage.Simulation Analysis: Arc - suppression Coil Ground
Leon
07/24/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!