What is the purpose of connecting the primary winding of a step-up transformer in series with the main supply and the secondary winding in parallel?

Encyclopedia
Field: Encyclopedia
0
China

The situation where the primary winding of a booster transformer is connected in series with the main power supply and the secondary winding is connected in parallel with the main power supply is not common in practical applications, because this connection method usually does not bring the expected benefits and may introduce unnecessary complexity and potential risks. However, assuming that this configuration is for a specific function, we can explore its possible purpose and application scenarios.

Series primary winding for purpose

When the primary winding of the booster transformer is connected to the main power supply in series, it means that the input end of the transformer is directly connected to the power line. This connection is usually intended to use the transformer as an impedance matching element or as a voltage regulator.

Purpose of parallel secondary winding

When the secondary winding of the booster transformer is in parallel with the main supply, it means that the voltage output by the secondary winding will be in parallel with the main supply voltage. This type of connection is usually used to provide a higher voltage output, and in some cases can be used to compensate for a lack of grid voltage.

Possible purpose

  • Voltage boost: If the grid voltage is lower than the required operating voltage, the voltage can be raised to the required level through a boost transformer. The secondary winding is in parallel with the main power supply to ensure that even in the case of grid voltage fluctuations, the load can get a stable high voltage.

  • Impedance matching: In some applications, it is necessary to match the impedance of the power supply to the impedance of the load to maximize power transfer efficiency. By connecting the primary windings in series, the impedance of the entire circuit can be adjusted.

  • Voltage regulation: The booster transformer can act as a voltage regulator to ensure that the voltage at both ends of the load is maintained at a constant level.

  • In the case of parallel connection, the booster transformer can supplement the shortage of grid voltage and ensure the voltage stability at both ends of the load.

  • Current limitation: In some cases, it may be necessary to limit the current through the load. By connecting the primary winding in series, it can play the role of current limiting. The parallel connection of the secondary windings ensures that the voltage at both ends of the load is not too affected by the current limitation.

Precautions in practical application

Although the above configuration may have some use in theory, there are several points to note in practical applications:

  • Safety:Placing the secondary winding in parallel with the main power supply can introduce safety hazards, especially if not properly designed, which can lead to short circuits or other dangerous conditions.

  • Efficiency: This configuration may not be the most efficient solution, as the loss and efficiency issues of the transformer need to be carefully considered.

  • Stability: A parallel connection may affect the stability of the system, especially if the grid voltage fluctuates.

More common ways to connect

In practical applications, it is more common to connect the primary winding of the booster transformer to the main power supply, while the secondary winding is directly connected to the load. This connection method can effectively increase the voltage, and is relatively simple and safe.

Sum up

The configuration of the primary winding of the booster transformer in series with the main power supply and the secondary winding in parallel with the main power supply can realize the functions of voltage boost, impedance matching, voltage regulation and current limitation in theory, but its safety and efficiency need to be carefully considered in practical applications. It is more common to connect the primary winding of the booster transformer directly to the main power supply and the secondary winding to the load. If you are considering this configuration in a specific application scenario, make sure that the design meets safety standards and has been thoroughly analyzed and tested.

Give a tip and encourage the author!

Recommended

Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
01/29/2026
Understanding Transformer Neutral Grounding
I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
01/29/2026
Voltage Imbalance: Ground Fault, Open Line, or Resonance?
Single-phase grounding, line break (open-phase), and resonance can all cause three-phase voltage unbalance. Correctly distinguishing among them is essential for rapid troubleshooting.Single-Phase GroundingAlthough single-phase grounding causes three-phase voltage unbalance, the line-to-line voltage magnitude remains unchanged. It can be classified into two types: metallic grounding and non-metallic grounding. Inmetallic grounding, the faulted phase voltage drops to zero, while the other two phas
11/08/2025
Composition and Working Principle of Photovoltaic Power Generation Systems
Composition and Working Principle of Photovoltaic (PV) Power Generation SystemsA photovoltaic (PV) power generation system is primarily composed of PV modules, a controller, an inverter, batteries, and other accessories (batteries are not required for grid-connected systems). Based on whether it relies on the public power grid, PV systems are divided into off-grid and grid-connected types. Off-grid systems operate independently without relying on the utility grid. They are equipped with energy-s
10/09/2025
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.