How are core loss and hysteresis loss related?

Encyclopedia
11/16/2024

Relationship Between Core Loss and Hysteresis Loss

Core loss (Core Loss) and hysteresis loss (Hysteresis Loss) are two common types of losses in electromagnetic devices. They are closely related but have distinct characteristics and mechanisms. Below is a detailed explanation of these two losses and their relationship:

Core Loss

Core loss refers to the total energy loss that occurs within the core material due to the magnetization process in an alternating magnetic field. Core loss primarily consists of two components: hysteresis loss and eddy current loss

Hysteresis Loss

Hysteresis loss is the energy loss due to the hysteresis phenomenon in the core material during the magnetization process. Hysteresis is the lagging of the magnetic induction B behind the magnetic field strength H. Each magnetization cycle consumes a certain amount of energy, which is dissipated as heat, forming the hysteresis loss.

Hysteresis loss can be expressed by the following formula:

7486d8d88d9be4d396e6a2aa45aece74.jpeg

where:

  • Ph is the hysteresis loss (unit: watts, W)

  • Kh is a constant related to the material properties

  • f is the frequency (unit: hertz, Hz)

  • Bm is the maximum magnetic induction (unit: tesla, T)

  • n is the hysteresis exponent (typically between 1.2 and 2)

  • V is the volume of the core (unit: cubic meters, m³)

Eddy Current Loss 

Eddy current loss is the energy loss due to eddy currents induced in the core material by the alternating magnetic field. These eddy currents flow within the material and generate joule heat, leading to energy loss. Eddy current loss is related to the resistivity of the core material, the frequency, and the magnetic induction.

Eddy current loss can be expressed by the following formula:

bf665b992ff297bbfa991e168c64114d.jpeg

where:

  • Pe  is the eddy current loss (unit: watts, W)

  • Ke is a constant related to the material properties

  • f is the frequency (unit: hertz, Hz)

  • Bm is the maximum magnetic induction (unit: tesla, T)

  • V is the volume of the core (unit: cubic meters, m³)

Relationship

Common Factors:

Frequency 

f: Both core loss and hysteresis loss are proportional to the frequency. Higher frequency results in more magnetization cycles within the core, leading to higher losses.

Maximum Magnetic Induction 

Bm : Both core loss and hysteresis loss are related to the maximum magnetic induction. Higher magnetic induction results in more intense magnetic field variations, leading to higher losses.

Core Volume 

V: Both core loss and hysteresis loss are proportional to the volume of the core. Larger volumes result in greater total losses.

Different Mechanisms:

  • Hysteresis Loss: Primarily caused by the hysteresis phenomenon in the core material, which is related to the magnetization history of the material.

  • Eddy Current Loss: Primarily caused by eddy currents induced in the core material by the alternating magnetic field, which are related to the resistivity of the material and the magnetic field strength.

Summary

Core loss is composed of hysteresis loss and eddy current loss. Hysteresis loss is mainly related to the magnetization characteristics of the core material, while eddy current loss is mainly related to the eddy currents induced by the alternating magnetic field. Both are influenced by frequency, magnetic induction, and core volume, but they have distinct physical mechanisms. Understanding the nature and relationship of these losses is crucial for optimizing the design of electromagnetic devices and improving their efficiency.

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
Frequency division method for measuring grid-to-ground insulation parameters
Frequency division method for measuring grid-to-ground insulation parameters
The frequency division method enables the measurement of grid-to-ground parameters by injecting a current signal of a different frequency into the open delta side of the potential transformer (PT).This method is applicable to ungrounded systems; however, when measuring the grid-to-ground parameters of a system where the neutral point is grounded via an arc suppression coil, the arc suppression coil must be disconnected from operation beforehand. Its measurement principle is shown in Figure 1.As
Leon
07/25/2025
The insulation parameters of the power grid to ground are measured by the tuning method
The insulation parameters of the power grid to ground are measured by the tuning method
The tuning method is suitable for measuring the ground parameters of systems where the neutral point is grounded via an arc suppression coil, but not applicable to ungrounded neutral point systems. Its measurement principle involves injecting a current signal with continuously varying frequency from the secondary side of the Potential Transformer (PT), measuring the returned voltage signal, and identifying the system's resonant frequency.During the frequency sweeping process, each injected heter
Leon
07/25/2025
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
In an arc - suppression coil grounding system, the rising speed of the zero - sequence voltage is greatly affected by the value of the transition resistance at the grounding point. The larger the transition resistance at the grounding point, the slower the rising speed of the zero - sequence voltage.In an ungrounded system, the transition resistance at the grounding point has basically no impact on the rising speed of the zero - sequence voltage.Simulation Analysis: Arc - suppression Coil Ground
Leon
07/24/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!