What is Phase & Phase Difference?

Edwiin
Field: Power switch
China

Definition: The phase of an alternating quantity represents the proportion of a complete cycle that the quantity has traversed relative to a designated reference origin. In the context of alternating electrical or physical phenomena, when two such quantities share identical frequencies, and their respective maxima (peaks) and minima (troughs) coincide precisely in time, these quantities are characterized as being in phase. This synchronization indicates a perfect temporal alignment, where the waveforms of the two quantities progress in unison without any relative displacement.

Examine the two alternating currents, Im1 and Im2, depicted in the figure below. These two electrical quantities not only reach their maximum and minimum amplitude peaks simultaneously but also cross the zero - value threshold precisely at the identical instant.

Phase Difference

Definition: The phase difference between two electrical quantities is defined as the angular disparity between the maximum values of two alternating quantities that share the same frequency.

Put differently, two alternating quantities exhibit a phase difference when, despite having identical frequencies, they reach their zero - crossing points at distinct moments. The angular separation between the zero - value instants of these two alternating quantities is referred to as the angle of phase difference.

Take, for instance, the two alternating currents with magnitudes Im1 and Im2, represented in vector form. Both vectors rotate at a consistent angular velocity of ω radians per second. Since these two currents cross the zero - value mark at different times, they are said to possess a phase difference denoted by the angle φ.

The quantity that reaches its positive maximum value ahead of another is termed the leading quantity. Conversely, the quantity that attains its positive maximum value after the other is referred to as the lagging quantity. In this context, current Im1 leads current Im2; equivalently, current Im2 lags behind current Im1.

Cycle: An alternating quantity is considered to have completed a full cycle when it traverses through an entire sequence of positive and negative values or spans 360 electrical degrees.

Give a tip and encourage the author!

Recommended

Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
01/29/2026
Understanding Transformer Neutral Grounding
I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
01/29/2026
Voltage Imbalance: Ground Fault, Open Line, or Resonance?
Single-phase grounding, line break (open-phase), and resonance can all cause three-phase voltage unbalance. Correctly distinguishing among them is essential for rapid troubleshooting.Single-Phase GroundingAlthough single-phase grounding causes three-phase voltage unbalance, the line-to-line voltage magnitude remains unchanged. It can be classified into two types: metallic grounding and non-metallic grounding. Inmetallic grounding, the faulted phase voltage drops to zero, while the other two phas
11/08/2025
Composition and Working Principle of Photovoltaic Power Generation Systems
Composition and Working Principle of Photovoltaic (PV) Power Generation SystemsA photovoltaic (PV) power generation system is primarily composed of PV modules, a controller, an inverter, batteries, and other accessories (batteries are not required for grid-connected systems). Based on whether it relies on the public power grid, PV systems are divided into off-grid and grid-connected types. Off-grid systems operate independently without relying on the utility grid. They are equipped with energy-s