What is Phase & Phase Difference?

Edwiin
05/20/2025

Definition: The phase of an alternating quantity represents the proportion of a complete cycle that the quantity has traversed relative to a designated reference origin. In the context of alternating electrical or physical phenomena, when two such quantities share identical frequencies, and their respective maxima (peaks) and minima (troughs) coincide precisely in time, these quantities are characterized as being in phase. This synchronization indicates a perfect temporal alignment, where the waveforms of the two quantities progress in unison without any relative displacement.

Examine the two alternating currents, Im1 and Im2, depicted in the figure below. These two electrical quantities not only reach their maximum and minimum amplitude peaks simultaneously but also cross the zero - value threshold precisely at the identical instant.

Phase Difference
Definition: The phase difference between two electrical quantities is defined as the angular disparity between the maximum values of two alternating quantities that share the same frequency.
Put differently, two alternating quantities exhibit a phase difference when, despite having identical frequencies, they reach their zero - crossing points at distinct moments. The angular separation between the zero - value instants of these two alternating quantities is referred to as the angle of phase difference.
Take, for instance, the two alternating currents with magnitudes Im1 and Im2, represented in vector form. Both vectors rotate at a consistent angular velocity of ω radians per second. Since these two currents cross the zero - value mark at different times, they are said to possess a phase difference denoted by the angle φ.
The quantity that reaches its positive maximum value ahead of another is termed the leading quantity. Conversely, the quantity that attains its positive maximum value after the other is referred to as the lagging quantity. In this context, current Im1 leads current Im2; equivalently, current Im2 lags behind current Im1.
Cycle: An alternating quantity is considered to have completed a full cycle when it traverses through an entire sequence of positive and negative values or spans 360 electrical degrees.
Edwiin

Hello,I'm Wdwiin. A decade of hands-on experience in electrical engineering, specializing in high-voltage systems, smart grids, and renewable energy technologies. Passionate about technical exchange and knowledge sharing, committed to interpreting industry trends with professional insights to empower peers. Connection creates value—let’s explore the boundless possibilities of the electrical world together!

Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
Frequency division method for measuring grid-to-ground insulation parameters
Frequency division method for measuring grid-to-ground insulation parameters
The frequency division method enables the measurement of grid-to-ground parameters by injecting a current signal of a different frequency into the open delta side of the potential transformer (PT).This method is applicable to ungrounded systems; however, when measuring the grid-to-ground parameters of a system where the neutral point is grounded via an arc suppression coil, the arc suppression coil must be disconnected from operation beforehand. Its measurement principle is shown in Figure 1.As
Leon
07/25/2025
The insulation parameters of the power grid to ground are measured by the tuning method
The insulation parameters of the power grid to ground are measured by the tuning method
The tuning method is suitable for measuring the ground parameters of systems where the neutral point is grounded via an arc suppression coil, but not applicable to ungrounded neutral point systems. Its measurement principle involves injecting a current signal with continuously varying frequency from the secondary side of the Potential Transformer (PT), measuring the returned voltage signal, and identifying the system's resonant frequency.During the frequency sweeping process, each injected heter
Leon
07/25/2025
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
In an arc - suppression coil grounding system, the rising speed of the zero - sequence voltage is greatly affected by the value of the transition resistance at the grounding point. The larger the transition resistance at the grounding point, the slower the rising speed of the zero - sequence voltage.In an ungrounded system, the transition resistance at the grounding point has basically no impact on the rising speed of the zero - sequence voltage.Simulation Analysis: Arc - suppression Coil Ground