What is Mutually Induced EMF?

Edwiin
05/29/2025

Definition of Mutually Induced EMF
Definition: The electromotive force (EMF) induced in a coil due to the change in magnetic flux produced by a neighboring coil linked to it is termed mutually induced EMF. To understand this phenomenon, consider the following example:
Take coil AB where coil B, having N2 turns, is placed in close proximity to coil A with N1 turns, as illustrated in the figure below:
Mutually Induced EMF Explanation
When switch (S) in the circuit is closed, current I1 flows through coil A, generating magnetic flux ϕ1. Most of this flux, denoted ϕ12, couples with adjacent coil B.Adjusting variable resistor R changes the current in coil A, altering the flux linked to coil B and inducing an EMF. This induced EMF is termed mutually induced EMF.The induced EMF direction follows Lenz’s Law, opposing the current change in coil A that caused it. A galvanometer (G) connected to coil B measures this EMF.The rate of flux change in coil B depends on the rate of current change in coil A, highlighting the mutual inductance relationship between the coils.
The magnitude of the mutually induced emf is directly proportional to the rate of change of current in coil A.The proportionality constant M is termed mutual inductance (or the coefficient of mutual inductance), which quantifies the magnetic coupling strength between the coils.
Edwiin

Hello,I'm Wdwiin. A decade of hands-on experience in electrical engineering, specializing in high-voltage systems, smart grids, and renewable energy technologies. Passionate about technical exchange and knowledge sharing, committed to interpreting industry trends with professional insights to empower peers. Connection creates value—let’s explore the boundless possibilities of the electrical world together!

Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
Frequency division method for measuring grid-to-ground insulation parameters
Frequency division method for measuring grid-to-ground insulation parameters
The frequency division method enables the measurement of grid-to-ground parameters by injecting a current signal of a different frequency into the open delta side of the potential transformer (PT).This method is applicable to ungrounded systems; however, when measuring the grid-to-ground parameters of a system where the neutral point is grounded via an arc suppression coil, the arc suppression coil must be disconnected from operation beforehand. Its measurement principle is shown in Figure 1.As
Leon
07/25/2025
The insulation parameters of the power grid to ground are measured by the tuning method
The insulation parameters of the power grid to ground are measured by the tuning method
The tuning method is suitable for measuring the ground parameters of systems where the neutral point is grounded via an arc suppression coil, but not applicable to ungrounded neutral point systems. Its measurement principle involves injecting a current signal with continuously varying frequency from the secondary side of the Potential Transformer (PT), measuring the returned voltage signal, and identifying the system's resonant frequency.During the frequency sweeping process, each injected heter
Leon
07/25/2025
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
In an arc - suppression coil grounding system, the rising speed of the zero - sequence voltage is greatly affected by the value of the transition resistance at the grounding point. The larger the transition resistance at the grounding point, the slower the rising speed of the zero - sequence voltage.In an ungrounded system, the transition resistance at the grounding point has basically no impact on the rising speed of the zero - sequence voltage.Simulation Analysis: Arc - suppression Coil Ground
Leon