• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Intelligent switchgear opening and closing time operation acc to IEC 61850

Dyson
Dyson
Field: Electrical Standards
China

For intelligent switchgear, the opening time is defined as the duration starting from the moment when the first message carrying the trip command (a GOOSE message in accordance with the IEC61850 series) is received through the interface, with the circuit - breaker initially in the closed position, and ending at the instant when the arcing contacts of all poles are separated.
Regarding the closing time of intelligent switchgear, it refers to the time span from the reception of the first message containing the close command (a GOOSE message following the IEC61850 series) via the interface, while the circuit - breaker is in the open position, to the moment when the contacts of all poles make contact, as illustrated in the figure.
When it comes to time measurements, it is necessary to verify the coherence between the position indication obtained via the serial interface (as shown in the figure) in the secondary system and the actual position of the intelligent switchgear.

Give a tip and encourage the author!
Recommended
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
What are the standards for calibration of online power quality monitoring devices?
What are the standards for calibration of online power quality monitoring devices?
Core Standards for Calibration of Online Power Quality Monitoring DevicesThe calibration of online power quality monitoring devices follows a comprehensive standard system, encompassing mandatory national standards, industry technical specifications, international guidelines, and requirements for calibration methods and equipment. The following provides a structured overview with practical recommendations for real-world applications.I. Core Domestic Standards1. DL/T 1228-2023 – Technical Require
Edwiin
10/30/2025
On-Site Testing of SF6 Gas Density Relays: Relevant Issues
On-Site Testing of SF6 Gas Density Relays: Relevant Issues
IntroductionSF6 gas is widely used as an insulating and arc-quenching medium in high-voltage and extra-high-voltage electrical equipment due to its excellent insulation, arc-extinguishing properties, and chemical stability. The insulation strength and arc-quenching capability of electrical equipment depend on the density of SF6 gas. A decrease in SF6 gas density can lead to two main hazards: Reduced dielectric strength of the equipment; Decreased interrupting capacity of circuit breakers.Additio
Felix Spark
10/27/2025
GIS Bolt Tightening Torque Standards by Material & Size
GIS Bolt Tightening Torque Standards by Material & Size
GIS (Gas-Insulated Metal-Enclosed Switchgear) contains numerous bolted and screwed connections, and the tightening torque varies depending on bolt material, size, and application. The recommended tightening torque values are listed below for reference:Table 1 Tightening Torque Values for Bolts of Different Materials and Sizes (N·m / kgf·cm) Thread Diameter (mm) Q235 (A3) Cast Insulator 45 Steel Chrome-Molybdenum Steel Stainless Steel M6 5.88/60 3.92/40 12.3/125 19.6/
Encyclopedia
10/24/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.