Motor protection

Encyclopedia
Field: Encyclopedia
0
China

Motor protection set


Motor protection is a set of devices and methods to protect a motor from failure and damage.


Type of motor fault


  • External motor fault

  • Unbalanced supply voltage

  • undervoltage

  • Reverse phase sequence

  • Loss of synchronization


Internal motor fault


  • Bearing failure

  • superheating

  • Winding fault

  • Ground fault


Motor protection device


  • Fuses: Fuses protect the motor by melting and interrupting the circuit during overload or short circuit.



  • Circuit breaker: The circuit breaker can be reset after an interruption failure and provides overload and undervoltage protection.



  • Overload relays: These devices interrupt circuits when large currents flow through them due to overload.



  • Thermal overload relays:  These devices use bimetal sheets or heating elements to sense the temperature rise of the motor current. When the current exceeds a preset value, the thermal element will bend or melt, causing the contact to open or close.



  •  Electronic or digital overload relays: These devices use a current transformer or shunt resistor to measure the motor current and use a microprocessor or solid-state circuit to control the contacts.



  •   Differential protective relays: These are devices that compare the current of a motor or its winding input and output terminals. When the current difference exceeds a certain value, it indicates that there is a winding fault, and the relay will trip the circuit.



  • Reverse protection relay: A device that detects the direction of rotation of a motor and prevents it from running in reverse.



Select motor protection equipment


Type and size of motor


  • Characteristics and ratings of the motor

  • Type and severity of the possible fault

  • NEC and other standard requirements

  • Cost and availability of equipment


Conclusion


Motor protection is an important aspect of electrical engineering, ensuring the safety and efficiency of motors and their circuits. Motor protection equipment is selected based on the type and size of the motor, the type and severity of possible failures, the requirements of NEC and other standards, and the cost and availability of the equipment. Motor protection devices include fuses, circuit breakers, overload relays, differential protection relays and reverse protection relays. Motor protection devices monitor and control parameters such as current, voltage, temperature, speed and torque to prevent or minimize damage to the motor and its circuits in the event of a failure or anomaly.


Give a tip and encourage the author!

Recommended

Rockwill Powers Cambodia’s Battambang Solar-Storage Project
The Battambang Conch PV + Energy Storage Power Station in Cambodia has successfully completed its grid-connected trial operation. The project utilized medium-voltage switchgear supplied by Rockwill Intelligent Electric Co., Ltd. Despite numerous challenges—including an extremely tight delivery schedule—Rockwill Intelligent delivered high-quality products and exceptional service throughout project execution, earning consistent praise from the client.Located in Battambang, Cambodia, the Battambang
12/24/2025
Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an
12/15/2025
Under What Conditions Will the Line Circuit Breaker Auto-Reclosing Signal Be Locked Out?
The line circuit breaker auto-reclosing signal will be locked out if any of the following conditions occur:(1) Low SF6 gas pressure in circuit breaker chamber at 0.5MPa(2) Insufficient energy storage in circuit breaker operating mechanism or low oil pressure at 30MPa(3) Busbar protection operation(4) Circuit breaker failure protection operation(5) Line distance protection zone II or zone III operation(6) Short lead protection operation of circuit breaker(7) Presence of remote tripping signal(8)
12/15/2025
Application of Auto-Reclosing Residual Current Protective Devices in Lightning Protection for Communication Power Supplies
1. Power Interruption Problems Caused by RCD False Tripping During Lightning StrikesA typical communication power supply circuit is shown in Figure 1. A residual current device (RCD) is installed at the power supply input terminal. The RCD primarily provides protection against electrical equipment leakage currents to ensure personal safety, while surge protective devices (SPDs) are installed on power supply branches to protect against lightning intrusions. When lightning strikes occur, the senso
12/15/2025
Related Products
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.