What is a type of step-up transformer?

Encyclopedia
Field: Encyclopedia
0
China

Step-up transformers (Step-up Transformers) are devices used to increase voltage levels and are widely applied in power transmission systems to reduce energy losses during transmission. Depending on various criteria, step-up transformers can be classified into different types. Here are the categories of step-up transformers according to different classification standards:

1. By Number of Phases

  • Single-phase Step-up Transformer: Suitable for residential or small commercial facilities.

  • Three-phase Step-up Transformer: Used in industrial and large commercial facilities, as well as in power transmission systems.

  • Multi-phase Step-up Transformer: May be encountered in special applications, such as avionics equipment.

2. By Cooling Method

  • Dry-type Step-up Transformer: Oil-free, uses air cooling, suitable for indoor installations.

  • Oil-immersed Step-up Transformer: Uses insulating oil as the cooling medium, suitable for outdoor or industrial environments.

  • Water-cooled Step-up Transformer: Used in certain special cases, such as space-limited areas.

3. By Number of Windings

  • Single-layer Winding Step-up Transformer: Has a simple winding structure.

  • Multi-layer Winding Step-up Transformer: Can provide higher voltage levels or larger capacities.

4. By Installation Location

  • Outdoor Step-up Transformer: Designed for outdoor environments, has a higher protection rating.

  • Indoor Step-up Transformer: For installation inside buildings, typically smaller in size and has lower protection requirements.

5. By Construction Form

  • Autotransformer Step-up Transformer: Has only one winding, part of which serves as the input and another part as the output, suitable for situations where the voltage levels are close.

  • Magnetic Coupled Step-up Transformer: Uses two or more windings, transferring energy via magnetic coupling.

  • LC Isolated Step-up Transformer: Uses a combination of inductors and capacitors to achieve electrical isolation and voltage boosting.

  • Multi-winding Transformer: Has three or more windings, used for complex voltage regulation needs.

6. By Voltage Level

  • Step-up Transformers of Various Voltage Levels: For example, 1000kV, 750kV, 500kV, 330kV, 220kV, 110kV, 66kV, 35kV, 20kV, 10kV, 6kV, etc., applicable throughout the entire power transmission network from power plants to end-users.

When selecting an appropriate step-up transformer, factors such as the specific application scenario, load requirements, installation location, and other considerations need to be taken into account. I hope this information is helpful. If you have any other questions or need more detailed explanations, please feel free to ask!


Give a tip and encourage the author!

Recommended

Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
01/29/2026
What’s the Difference Between Rectifier Transformers and Power Transformers?
What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
01/29/2026
How to Judge, Detect and Troubleshoot Transformer Core Faults
1. Hazards, Causes, and Types of Multi-Point Grounding Faults in Transformer Cores1.1 Hazards of Multi-Point Grounding Faults in the CoreUnder normal operation, a transformer core must be grounded at only one point. During operation, alternating magnetic fields surround the windings. Due to electromagnetic induction, parasitic capacitances exist between the high-voltage and low-voltage windings, between the low-voltage winding and the core, and between the core and the tank. The energized windin
01/27/2026
A Brief Discussion on the Selection of Grounding Transformers in Boost Stations
A Brief Discussion on the Selection of Grounding Transformers in Boost StationsThe grounding transformer, commonly referred to as "grounding transformer," operates under the condition of being no-load during normal grid operation and overloaded during short-circuit faults. According to the difference in filling medium, common types can be divided into oil-immersed and dry-type; according to phase number, they can be classified into three-phase and single-phase grounding transformers. The groundi
01/27/2026
Related Products
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.