What is a type of step-up transformer?

Encyclopedia
10/16/2024

Step-up transformers (Step-up Transformers) are devices used to increase voltage levels and are widely applied in power transmission systems to reduce energy losses during transmission. Depending on various criteria, step-up transformers can be classified into different types. Here are the categories of step-up transformers according to different classification standards:

1. By Number of Phases

  • Single-phase Step-up Transformer: Suitable for residential or small commercial facilities.

  • Three-phase Step-up Transformer: Used in industrial and large commercial facilities, as well as in power transmission systems.

  • Multi-phase Step-up Transformer: May be encountered in special applications, such as avionics equipment.

2. By Cooling Method

  • Dry-type Step-up Transformer: Oil-free, uses air cooling, suitable for indoor installations.

  • Oil-immersed Step-up Transformer: Uses insulating oil as the cooling medium, suitable for outdoor or industrial environments.

  • Water-cooled Step-up Transformer: Used in certain special cases, such as space-limited areas.

3. By Number of Windings

  • Single-layer Winding Step-up Transformer: Has a simple winding structure.

  • Multi-layer Winding Step-up Transformer: Can provide higher voltage levels or larger capacities.

4. By Installation Location

  • Outdoor Step-up Transformer: Designed for outdoor environments, has a higher protection rating.

  • Indoor Step-up Transformer: For installation inside buildings, typically smaller in size and has lower protection requirements.

5. By Construction Form

  • Autotransformer Step-up Transformer: Has only one winding, part of which serves as the input and another part as the output, suitable for situations where the voltage levels are close.

  • Magnetic Coupled Step-up Transformer: Uses two or more windings, transferring energy via magnetic coupling.

  • LC Isolated Step-up Transformer: Uses a combination of inductors and capacitors to achieve electrical isolation and voltage boosting.

  • Multi-winding Transformer: Has three or more windings, used for complex voltage regulation needs.

6. By Voltage Level

  • Step-up Transformers of Various Voltage Levels: For example, 1000kV, 750kV, 500kV, 330kV, 220kV, 110kV, 66kV, 35kV, 20kV, 10kV, 6kV, etc., applicable throughout the entire power transmission network from power plants to end-users.

When selecting an appropriate step-up transformer, factors such as the specific application scenario, load requirements, installation location, and other considerations need to be taken into account. I hope this information is helpful. If you have any other questions or need more detailed explanations, please feel free to ask!


Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!