What is a Voltage Transformer ?

Encyclopedia
08/08/2024

What is a  Voltage Transformer ?

Voltage Transformer Definition

A voltage transformer, also known as a potential transformer, steps down high system voltages to safer, lower levels suitable for standard meters and relays.

58be1e01-0964-4823-8976-7af5dbede7fb.jpg


 

Basic Operation

These transformers connect their primary windings across a phase and the ground, operating like other step-down transformers but specifically for voltage management.

Standard Secondary Voltage

The secondary voltage output of a typical voltage transformer is generally 110 V.

Common Errors

Errors in voltage transformers include deviations in voltage ratios and phase alignments, impacting accuracy.

dd67706f-76d8-44e1-8695-f40b98b92b53.jpg

Is – Secondary current.

Es – Secondary induced emf.

Vs – Secondary terminal voltage.

Rs – Secondary winding resistance.

Xs – Secondary winding reactance.

Ip – Primary current.

Ep – Primary induced emf.

Vp – Primary terminal voltage.

Rp – Primary winding resistance.

Xp – Primary winding reactance.

KT – Turns ratio = Numbers of primary turns/number of secondary turns.

I0 – Excitation current.

Im – Magnetizing component of I0.

Iw – Core loss component of I0.

Φm – Main flux.

β – Phase angle error.

5ebbf17e-7dcd-4a18-a3c8-7196d72943c4.jpg

Cause of Errors

The voltage applied to the primary of the potential transformer first drops due to the internal impedance of the primary. Then it appears across the primary winding and then transformed proportionally to its turns ratio, to the secondary winding. This transformed voltage across the secondary winding will again drop due to the internal impedance of the secondary, before appearing across burden terminals. This is the reason of errors in potential transformer.

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!