Fourier Series and Fourier Transform

Electrical4u
Field: Basic Electrical
0
China

Fourier Series Fourier Transform

Sometimes all the information in time domain is not sufficient. This makes us to move to frequency domain of the signal for extracting more information about the signal. This movement from one domain to other domain is known as transformation. For changing the domain of signal from time to frequency we have many tools. Fourier Series and Fourier Transform are two of the tools in which we decompose the signal into harmonically related sinusoids. With such decomposition, a signal is said to be represented in frequency domain.
Most of the practical signals can be decomposed into sinusoids. Such a decomposition of periodic signals is called a Fourier series.

Frequency Analysis

Just like a white light can be decomposed into seven colors, a periodic signal can also be decomposed into a liner weighted sum of harmonically related frequencies. This linear weighted sum of harmonically related sinusoids or complex exponentials is known as Fourier Series or Transform. In general, decomposition of any signal into its frequency related components is called frequency analysis. Like analysis of a light into colors is actually a form of frequency analysis, hence the Fourier series and Fourier transform are also tools of frequency analysis.

This can be clearer from the following.
Suppose if we pass a light through a prism, it gets split into seven colors VIBGYOR. Each color has a particular frequency or a range of frequencies. In the same way, if we pass a periodic signal through a Fourier tool, which plays the role of prism, the signal is decomposed into a Fourier series.
prism light refraction

Signals and Vectors Analogy

An N dimension vector needs N dimensions for its representation. Like an ant moving on a table needs two dimensions for the representation of its position on the table i.e. x and y. Also we are familiar with i, j, k coordinate system for a vector representation in three dimensions. This unit vector i, j and k are orthogonal to each other. In the same way if we treat a signal as a multidimensional vector we need many more dimensions which are orthogonal to each other. It was the genius of J. B. J. Fourier who invented multi-dimensions, which are orthogonal to each other. These are sinusoids with harmonically related sinusoids or complex exponential. Consider the dimensions (also called bases)
sinω0t sin2ω0t sin3ω0t sin4ω0t ……..sinnω0t
cosω0t cos2ω0t cos3ω0t cos4ω0t……..cosnω0t
Thus, all sinnω0t are orthogonal with Sinmω0t (n≠m) and we, therefore can use sinω0t, sin2ω0t… ∞ as the primary dimensions (also called bases) to express a periodic signal. Similarly, we can also use cosω0t, cos2ω0t, cos3ω0t… ∞ as the additional dimensions when sinω0t dimensions cannot be used. We will see for even signals only cosine terms will be suitable and for odd signal only sine terms will be suitable. For a periodic signal neither an odd nor even, we use both sine and cosine terms.

NOTE
Only periodic signals can be represented as Fourier series provided the signal follows the Dirichlet’s conditions. For non-periodic signals, we have Fourier transform tool which transform the signal from time domain to frequency domain.
Resolution of signal into its harmonically related frequencies is known as Fourier Analysis while the inverse i.e. recombination, is known as Fourier Sysnthesis.

Dirichlet’s Conditions

x (t) is absolutely integrable over any period, that is,

x (t) has a finite number of maxima and minima within any finite interval of t.
x (t) has a finite number of discontinuities within any finite interval of t, and each of these discontinuities are finite.
Note that the Dirichlet’s conditions are sufficient but not necessary conditions for the Fourier series representation.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!

Recommended

Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
01/30/2026
Neutral point grounding operation mode for 110kV~220kV power grid transformers
The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
01/29/2026
Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
01/29/2026
HECI GCB for Generators – Fast SF6 Circuit Breaker
1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
01/06/2026
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.