Capacitance Meter

Electrical4u
Field: Basic Electrical
0
China

What Is A Capacitance Meter

A capacitance meter is a piece of electronic test equipment whose purpose is to measure capacitance, mostly of discrete capacitors. The capacitance meter works based off of the directly proportional relationship between capacitance and a time constant.

This relation is used in this method of measurement. So, we can first go through a simple RC circuit with a supply voltage of VIN (shown below).

capacitance meter
During the charging period of the capacitor, the voltage across the capacitor at any instant is

The time needed to charge the capacitor to exactly 63.5 percent of the total input voltage.
is termed as time constant. It is denoted by ‘τ’.

Now, Assume a capacitor which is charged using a constant current source and the capacitor gets discharged through a resistor having a fixed resistance. To measure the capacitance of this circuit, we can implement a 555 timer together with a few digital test apparatus. The clear way of measuring the capacitance is by measuring the time period of oscillations. The reading can be obtained directly in nanofarads or microfarads by selecting the exact size of the charging resistance.

capacitance meter
When compared to other capacitance measuring techniques, this meter is capable to hold electrolytic which is up to tens of thousands of Farad.

If the testing capacitor has any leakage, this method will create the value of the capacitance to be smaller than the actual value. This method is also an efficient indicator of the behavior of the test capacitor in the majority bypass and timing circuits. The block diagram of a basic digital capacitance meter with the 555 timer IC is shown below.
capacitance meter
Here, we can see a 555 timer in the circuit. It works as an astable multivibrator. The frequency of this multivibrator is governed by the unknown capacitance value (CX). The output of this multivibrator is connected to a digital counter. This counter can measure the length of the cycle of the square wave.
Cycle length of the square wave which is formed by 555 timers can be calculated using the formula:

On the peak value of the charging curve, a digital counter will get reset. At this time, a clock of 100 kHz pulses is made ON and it is routed to the counter. Next, after the completion of discharge part of the cycle, the display will get updated and we can simply read out the value of the capacitor. To get the direct display of the capacitance value simply and correctly, the selection of charging currents and reference frequency should be apt.

The shielding of leads should be made assure and for low capacity measurements, it should be kept short. This is because the hum of 50 Hz can result in some minor instability.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!

Recommended

Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
01/30/2026
Neutral point grounding operation mode for 110kV~220kV power grid transformers
The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
01/29/2026
Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
01/29/2026
HECI GCB for Generators – Fast SF6 Circuit Breaker
1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
01/06/2026
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.